Quality Remote Diaphragm Seal Pressure Transmitter High Temperature 400°C factory
<
Quality Remote Diaphragm Seal Pressure Transmitter High Temperature 400°C factory
Quality Remote Diaphragm Seal Pressure Transmitter High Temperature 400°C factory
Quality Remote Diaphragm Seal Pressure Transmitter High Temperature 400°C factory
Quality Remote Diaphragm Seal Pressure Transmitter High Temperature 400°C factory
>

Remote Diaphragm Seal Pressure Transmitter High Temperature 400°C

Brand Name: QINWEIYB
Model Number: QWYB-517
Place of Origin: China
Certification: Explosion-proof certificate ,Safety certificate
Minimum Order Quantity: 1Set
Price: Negotiable
Supply Ability: 100PCS/Month

Product Details


Range: 0-35kpa--3.5Mpa Thread: Chuck Connection 50.5mm
Connection: G12 G1/2, G14 G1/4, M20 M20*1.5 Input Power: 24vdc
Response Time: ≤10 Ms Precision: ±0.5%FS
Storage Temperature: -40 To 125 °C Output: 4~20mA,0-5V,0-10V,RS485
Grade: Industrial Output Signal: 4-20 MA
Highlight

High Temperature Pressure Transmitter

,

High Temp Pressure Transmitter

,

Pressure Transmitter 24VDC

Product Description

High Temperature Pressure Transmitter with Remote Diaphragm Seal

1. Why You Need It

Processes at 200-400°C — thermal oil, molten media, superheated steam — quickly destroy a transmitter mounted directly on the line. This high-temperature transmitter uses a remote diaphragm seal and capillary system that isolates the sensing element from the heat, while a DC704 high-temperature fill fluid transmits pressure reliably. A Hastelloy C-276 diaphragm handles corrosive media, and cooling extension options extend service to the most extreme duties.

2. Working Principle

Process pressure acts on a remote diaphragm seal mounted at the process connection. The seal's fill fluid — DC704, a silicone-based high-temperature fluid — transmits the pressure through a capillary to the transmitter's sensing element, which is located away from the heat. This isolation keeps the electronics at a safe ambient temperature while the seal and fill fluid handle process temperatures up to 400°C, with a response time of ≤10 ms.

3. Key Advantages

  • Rated for process up to 400°C
  • Remote diaphragm seal + capillary
  • DC704 high-temperature fill fluid
  • Hastelloy C-276 diaphragm
  • Response time ≤10 ms
  • 4-20 mA / 0-5 V / 0-10 V / RS485
  • Multiple connection threads
  • Range 0-35 kPa to 3.5 MPa
  • Cooling extension options
  • Industrial grade

Common Pain Points & Solutions

ProblemConventional IssueOur SolutionResult
Process heat kills sensorsDirect-mount fails at heatRemote seal isolates electronicsReliable at 400°C
Fill fluid degradesStandard fluids vaporizeDC704 high-temp fill fluidStable pressure transmission
Corrosive hot mediaStandard diaphragm corrodesHastelloy C-276 diaphragmLong life in aggressive media
Slow thermal responseStandard designs lag≤10 ms response timeFast process feedback

Application Cases

Industry: Thermal Oil
Application: Heating loop pressure
Medium: Thermal oil
Pressure Range: 0-1.6 MPa
Operating Temperature: 200-320 °C
Installation Environment: Heating system
Customer Challenge: Reliable hot-oil pressure
Previous Problem: Direct-mount sensor failed
Solution: Remote seal transmitter, 300°C
Installation Location: Heat exchanger loop
Result: Reliable hot-oil measurement
Industry: Chemical
Application: Molten salt process pressure
Medium: Molten salt
Pressure Range: 0-1.0 MPa
Operating Temperature: 300-400 °C
Installation Environment: Chemical reactor
Customer Challenge: Corrosion + heat resistance
Previous Problem: Diaphragm corroded
Solution: Hastelloy C-276 remote seal
Installation Location: Reactor vessel
Result: Corrosion-resistant at 400°C
Industry: Steam
Application: Superheated steam pressure
Medium: Superheated steam
Pressure Range: 0-3.5 MPa
Operating Temperature: 250-400 °C
Installation Environment: Steam line
Customer Challenge: Protect electronics from heat
Previous Problem: Electronics overheated
Solution: Cooling extension + remote seal
Installation Location: Steam header
Result: Electronics protected, stable reading
Industry: Food
Application: Fryer / hot oil pressure
Medium: Edible oil
Pressure Range: 0-0.6 MPa
Operating Temperature: 150-200 °C
Installation Environment: Food processing
Customer Challenge: Accurate hygienic measurement
Previous Problem: Sensor degraded from heat
Solution: DC704 fill, remote seal transmitter
Installation Location: Fryer system
Result: Accurate, long-life measurement

Technical Specifications

SpecificationValue
Process TemperatureUp to 400°C
DesignRemote diaphragm seal + capillary
Fill FluidDC704 (high-temperature)
Diaphragm MaterialHastelloy C-276
Measurement Range0-35 kPa to 3.5 MPa
Output4-20 mA / 0-5 V / 0-10 V / RS485
Response Time≤10 ms
ConnectionG1/2, G1/4, M20×1.5

FAQ

Q: How does it withstand 400°C?

The transmitter uses a remote diaphragm seal and capillary system that physically separates the sensing element from the hot process. The seal, mounted at the process connection, transmits pressure through a capillary filled with DC704 high-temperature fluid to the electronics, which remain at ambient temperature. This isolation lets the seal handle process temperatures up to 400°C without overheating the sensor.

Q: What fill fluid is used?

The fill fluid is DC704, a silicone-based high-temperature fluid. It remains stable and does not vaporize or decompose at the high temperatures where standard fill fluids would fail. The fill fluid's thermal stability is critical, because any degradation would change the transmitted pressure and corrupt the measurement.

Q: What is the diaphragm material?

The diaphragm is Hastelloy C-276, a nickel-chromium-molybdenum alloy with excellent resistance to corrosion and high-temperature media. It withstands aggressive chemicals, hot oils and molten media that would attack standard stainless steel, ensuring long service life in demanding high-temperature applications.

Q: What is the measurement range?

The measurement range is 0-35 kPa to 3.5 MPa, covering low-pressure hot processes up to moderate high-pressure thermal duties. The span is configured for the application, and the transmitter is calibrated so the 4-20 mA output corresponds to the required pressure range.

Q: What is the response time?

The response time is ≤10 ms, providing fast feedback for thermal and process control loops. The capillary system is engineered to minimize the volume of fill fluid and its thermal effects, keeping the measurement responsive even at high temperatures.

Q: What connections are available?

Threaded process connections include G1/2, G1/4 and M20×1.5, with the remote diaphragm seal mounted at the process connection. The choice of thread depends on the vessel or pipe fitting, and the seal is selected to match the process pressure and temperature.

Q: Why use a remote seal instead of direct mounting?

Direct mounting exposes the transmitter's electronics and sensing element to the full process temperature, which degrades and eventually destroys them. A remote seal moves the sensor away from the heat, using a capillary and fill fluid to transmit pressure. This extends service life dramatically and is the standard solution for process temperatures above the sensor's safe limit.

Q: Can it handle corrosive media?

Yes. The Hastelloy C-276 diaphragm provides excellent corrosion resistance for aggressive chemicals, molten salts and hot corrosive media. For the most demanding media, the diaphragm material and fill fluid are selected together to match both the chemistry and the temperature, ensuring reliable long-term operation.

Q: What is the role of the cooling extension?

A cooling extension is an optional component that further reduces the temperature reaching the transmitter by adding thermal mass and surface area between the hot seal and the sensor. It is used in extreme high-temperature applications — such as superheated steam or molten media — to keep the electronics safely below their operating limit.

Q: Where is it used?

It is used in thermal oil heating systems, molten salt processes, superheated steam lines and hot oil food processing. Anywhere process temperatures exceed what a direct-mount transmitter can tolerate, the high-temperature remote-seal transmitter provides reliable pressure measurement without sacrificing sensor life.

Product Highlights

High temperature pressure transmitter with remote diaphragm seal and capillary system for process temperatures up to 400°C. DC704 high-temperature fill fluid, Hastelloy C-276 diaphragm, and cooling extension options.

Related Products
Quality Petroleum Radar Level Gauge 26GHz High Temperature Industrial factory

Petroleum Radar Level Gauge 26GHz High Temperature Industrial

Petroleum Radar Level Gauge for High-Temperature Industrial Tank Measurement Oil storage is a high-stakes business: every millimeter of level represents valuable product, and every measurement error becomes an inventory loss or a safety risk. The QWRD80G603 petroleum radar level gauge brings 26GHz ...

Quality Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor factory

Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor

Portable FMCW Radar Level Gauge for Quick, Accurate Liquid Measurement Anywhere Sometimes you do not need a permanently installed instrument; you need a reliable level reading here, now, at any tank in the plant or in the field. The QWRD80G611 portable FMCW radar level gauge brings laboratory-grade ...

Quality Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay factory

Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay

Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.

Quality Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement factory

Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement

Universal Gauge Pressure Transmitter for Oil, Water and Gas 1. Why You Need a Gauge Pressure Transmitter Most industrial pressure measurements — pump discharge, line pressure, tank head, filter differential — are expressed relative to the surrounding atmosphere. A gauge pressure transmitter reads ...

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.