Quality Oil Pressure Calibration Bench 6MPa -80KPa Vacuum Gauge Calibrator factory
Quality Oil Pressure Calibration Bench 6MPa -80KPa Vacuum Gauge Calibrator factory
Quality Oil Pressure Calibration Bench 6MPa -80KPa Vacuum Gauge Calibrator factory
Quality Oil Pressure Calibration Bench 6MPa -80KPa Vacuum Gauge Calibrator factory
>

Oil Pressure Calibration Bench 6MPa -80KPa Vacuum Gauge Calibrator

Brand Name: QINWEIYB
Model Number: QWYB-510
Place of Origin: China
Minimum Order Quantity: 1Set
Price: Negotiable
Supply Ability: 100PCS/Month

Product Details


Power: 5VDC / 12VDC/24VDC /9-30vdc Range: -0.1~60MPa
Flange Pressure: 1/4 - 18 NPT Thread Electrical Connection: M12 Connector
Type: Gauge, Absolute, Sealed Gauge Stability: ± 0.10% Of URL For 12 Months
Output Type: Analog And Digital Working Temperature: 5~50℃
Voltage: 5±0.5VDc Accuracy: ±0.1% FS
Highlight

Oil Pressure Calibration

,

6MPa Vacuum Gauge Calibrator

,

80Kpa Vacuum Gauge Calibrator

Product Description

Oil Pressure Calibration Bench for Pressure Gauge and Transmitter Verification

1. Why You Need It

Every plant that relies on pressure measurement needs a trusted reference to verify its gauges and transmitters against — otherwise, calibration drifts go unnoticed until they cause process errors or safety issues. This oil pressure calibration bench generates stable pressures from -80 kPa vacuum to 60 MPa, letting technicians calibrate and verify pressure gauges, transmitters and switches against a ±0.1% FS reference. It is the metrology workhorse for instrument workshops, quality labs and field service teams.

2. Working Principle

The calibration bench uses a hand pump or pneumatic/hydraulic pressure source to generate a precise, adjustable test pressure, with oil as the pressure-transmitting medium for high ranges. The pressure under test is compared against an internal high-accuracy reference, and the instrument under test is adjusted to match. With analog and digital output options, the bench provides a stable, repeatable reference for verifying measurement accuracy across a wide range.

3. Key Advantages

  • Range -0.1 to 60 MPa (vacuum to high)
  • ±0.1% FS reference accuracy
  • Analog and digital output
  • Gauge / absolute / sealed gauge
  • 5-50 °C working temperature
  • Multiple power options (5/12/24 V)
  • M12 electrical connection
  • ±0.10% URL 12-month stability
  • Suitable for gauges and transmitters
  • Portable bench-top design

Common Pain Points & Solutions

ProblemConventional IssueOur SolutionResult
Unverified instrumentsCalibration drifts unnoticed±0.1% FS reference benchTrusted calibration verification
Wide pressure coverage neededSingle-range calibrators limited-0.1 to 60 MPa rangeOne bench, many instruments
Vacuum calibration difficultPressure-only calibrators-80 kPa vacuum capabilityFull vacuum and pressure testing
Reference drift over timeUnstable references±0.10% URL / 12-month stabilityConsistent calibration results

Application Cases

Industry: Instrument Workshop
Application: Periodic gauge calibration
Medium: Hydraulic oil
Pressure Range: -0.1 to 60 MPa
Operating Temperature: 5-40 °C
Installation Environment: Workshop
Customer Challenge: Verify gauge accuracy
Previous Problem: No reliable reference
Solution: Calibration bench, ±0.1% FS
Installation Location: Calibration bench
Result: Traceable gauge verification
Industry: Quality Lab
Application: Transmitter acceptance testing
Medium: Oil
Pressure Range: 0-60 MPa
Operating Temperature: 20-25 °C
Installation Environment: Metrology lab
Customer Challenge: Validate incoming transmitters
Previous Problem: Unverified instruments
Solution: Bench with digital output
Installation Location: Test station
Result: Validated transmitter accuracy
Industry: Field Service
Application: On-site gauge checking
Medium: Oil
Pressure Range: -0.1 to 6 MPa
Operating Temperature: 5-45 °C
Installation Environment: Plant site
Customer Challenge: Portable calibration
Previous Problem: Bulky, fixed rigs
Solution: Portable calibration bench
Installation Location: Instrument bay
Result: Convenient on-site calibration
Industry: Process Plant
Application: Pressure switch set-point check
Medium: Oil
Pressure Range: 0-10 MPa
Operating Temperature: 10-40 °C
Installation Environment: Maintenance shop
Customer Challenge: Verify switch set points
Previous Problem: Manual, imprecise checks
Solution: Bench, analog + digital
Installation Location: Maintenance shop
Result: Accurate switch verification

Technical Specifications

SpecificationValue
Measurement Range-0.1 to 60 MPa
Accuracy±0.1% FS
Stability±0.10% URL / 12 months
Output TypeAnalog and digital
Pressure TypeGauge / Absolute / Sealed Gauge
Working Temperature5-50 °C
Power Supply5 / 12 / 24 V DC (9-30 V DC)
Electrical ConnectionM12

FAQ

Q: What is a pressure calibration bench?

A pressure calibration bench is a precision instrument used to generate known pressures and compare them against the reading of a pressure gauge, transmitter or switch. It provides a stable reference pressure so technicians can verify accuracy, adjust calibration and document traceability. It is the standard tool in instrument workshops and calibration laboratories.

Q: What is the pressure range?

The bench covers a range of -0.1 to 60 MPa, spanning deep vacuum (-80 kPa) through to high pressure (60 MPa). This wide range allows calibration of most industrial pressure gauges, transmitters and switches with a single bench, eliminating the need for multiple calibrators.

Q: How accurate is it?

The reference accuracy is ±0.1% FS, providing a trustworthy standard for verifying field instruments that typically have 0.25-1% FS accuracy. The ±0.10% URL stability over 12 months ensures the reference itself remains reliable between recalibrations.

Q: Can it calibrate vacuum instruments?

Yes, the bench generates pressures down to -80 kPa vacuum, so it can calibrate vacuum gauges and transmitters as well as positive-pressure instruments. This vacuum capability is important for process plants that use vacuum measurement and need to verify those instruments.

Q: What instruments can it calibrate?

It can calibrate pressure gauges, pressure transmitters, pressure transducers and pressure switches. The analog and digital outputs and the wide range allow the bench to drive and verify almost any pressure instrument used in industrial service.

Q: Why use oil as the medium?

Oil is used as the pressure-transmitting medium for high pressure ranges because it is incompressible and provides stable, controllable pressure without the risk of gas expansion. For lower ranges and vacuum, the bench's pressure source is configured accordingly. Oil-filled systems are standard for high-pressure calibration.

Q: What output does it provide?

The bench provides analog and digital output options, allowing it to interface with the instrument under test and with data-logging or documentation systems. This supports both manual calibration and automated, traceable calibration procedures.

Q: How is it powered?

It supports multiple power options — 5 V DC, 12 V DC, 24 V DC and 9-30 V DC — making it flexible for different workshop and field power sources. The M12 electrical connection provides a secure interface.

Q: How often should the bench be recalibrated?

The bench itself should be recalibrated against a higher-level standard on a periodic basis, typically annually, to maintain its ±0.1% FS reference accuracy. Its ±0.10% URL 12-month stability means it holds its calibration well, but traceability to a national standard is maintained through periodic recalibration.

Q: Where is it used?

It is used in instrument workshops, quality and metrology laboratories, field service teams and process plant maintenance shops. Anywhere pressure gauges, transmitters and switches must be verified and calibrated to maintain measurement accuracy and traceability.

Product Highlights

Oil Pressure Calibration Bench for Pressure Gauge and Transmitter Verification 1. Why You Need It Every plant that relies on pressure measurement needs a trusted reference to verify its gauges and transmitters against — otherwise, calibration drifts go unnoticed until they cause process errors or ...

Related Products
Quality Petroleum Radar Level Gauge 26GHz High Temperature Industrial factory

Petroleum Radar Level Gauge 26GHz High Temperature Industrial

Petroleum Radar Level Gauge for High-Temperature Industrial Tank Measurement Oil storage is a high-stakes business: every millimeter of level represents valuable product, and every measurement error becomes an inventory loss or a safety risk. The QWRD80G603 petroleum radar level gauge brings 26GHz ...

Quality Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor factory

Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor

Portable FMCW Radar Level Gauge for Quick, Accurate Liquid Measurement Anywhere Sometimes you do not need a permanently installed instrument; you need a reliable level reading here, now, at any tank in the plant or in the field. The QWRD80G611 portable FMCW radar level gauge brings laboratory-grade ...

Quality Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay factory

Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay

Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.

Quality Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement factory

Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement

Universal Gauge Pressure Transmitter for Oil, Water and Gas 1. Why You Need a Gauge Pressure Transmitter Most industrial pressure measurements — pump discharge, line pressure, tank head, filter differential — are expressed relative to the surrounding atmosphere. A gauge pressure transmitter reads ...

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.