Split Temperature Transmitter 4-20mA 12-24VDC 175mm Rod Length

Brand Name: QINWEIYB
Model Number: QW-SLS66
Place of Origin: China
Certification: Safety certificate
Minimum Order Quantity: 1Set
Price: Negotiable
Supply Ability: 100PCS/Month

Product Details


Dimension: 106mm*88mm*33mm Housing Material: Stainless Steel
Communication: Digital Communication Input Signal: PT100
Certifications: ATEX, IECEx, FM, CSA, CE Output Signal: 4-20mA
Overpressure Limit: 2 Times The Maximum Range Material: Stainless Steel
Sensor Length: 500mm(19.68in) Analog Output: RT-A: 4~20mA
Highlight

Split Temperature Transmitter 4-20mA

,

Split Temperature Transmitter 24VDC

,

Split Temperature Transmitter 12VDC

Product Description

Split Temperature Transmitter With 4-20mA Output 12-24VDC Power Supply And 175mm Rod Length

In contrast to the integrated type, a split temperature transmitter refers to the physical separation of the temperature sensor (temperature-measuring element) and the signal transmitter module, which are connected by wires and usually installed in different locations.

  • The transmitter module is environmentally friendly: The transmitter is installed in a control room with suitable temperature, no vibration, and no corrosive gases, avoiding the influence of harsh on-site environments (high temperature, high humidity, strong vibration), thus having a longer lifespan and better stability.
  • Maintenance and debugging are convenient: As the transmitter is located in the control cabinet, technicians can easily perform operations such as calibration, replacement, and parameter configuration (such as modifying the measurement range) without going to the site, which is safe and efficient.
  • Save high-end material costs: For systems requiring a large number of temperature measurement points, all transmitters can be centrally installed in the same cabinet, which is more space-saving and cost-effective than purchasing multiple integrated transmitters.
  • Flexible sensor selection: Different length and material protective sleeves can be flexibly matched with the sensors, while the transmitter part is universal.

Product Parameters

Product Name:
Split Digital Display Temperature Sensor
Temperature Range:
-40 - 120°C
Output:
4 - 20mA
Rod Length:
175mm
Installation Thread:
Adjustable M20*1.5
Power Supply:
12 - 24VDC

Integrated vs. Split: How to Choose?

Characteristics Integrated Temperature Transmitter Split Temperature Transmitter
Structure Sensor and transmitter integrated Sensor and transmitter separated
Installation All on-site, simple and quick On-site + control room, complex, wiring required
Signal Transmission Outputs strong 4-20mA signal, strong anti-interference Transmits weak analog signal, prone to interference
Maintenance Needs on-site operation, inconvenient Operates in control room, convenient and quick
Environmental Adaptability Transmitter needs to withstand on-site environment Transmitter in good environment, longer lifespan
Cost High single-unit cost, but low overall installation cost Low single-module cost, but high overall wiring cost
Applicable Scenarios Scattered measurement points, renovation projects, general working conditions Harsh environment, dense measurement points, large new construction projects

Split-type temperature transmitters are a classic and reliable solution. They separate sensitive electronic components from harsh on-site environments. With the advantages of easy maintenance and centralized management, they still hold an important position in specific industrial fields, especially in large-scale process industries. The choice between integral and split types lies in a comprehensive balance of on-site environment, installation cost, maintenance convenience and signal reliability.

Product Highlights

Split Temperature Transmitter With 4-20mA Output 12-24VDC Power Supply And 175mm Rod Length In contrast to the integrated type, a split temperature transmitter refers to the physical separation of the temperature sensor (temperature-measuring element) and the signal transmitter module, which are ...

Related Products
Quality Petroleum Radar Level Gauge 26GHz High Temperature Industrial factory

Petroleum Radar Level Gauge 26GHz High Temperature Industrial

Petroleum Radar Level Gauge for High-Temperature Industrial Tank Measurement Oil storage is a high-stakes business: every millimeter of level represents valuable product, and every measurement error becomes an inventory loss or a safety risk. The QWRD80G603 petroleum radar level gauge brings 26GHz ...

Quality Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor factory

Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor

Portable FMCW Radar Level Gauge for Quick, Accurate Liquid Measurement Anywhere Sometimes you do not need a permanently installed instrument; you need a reliable level reading here, now, at any tank in the plant or in the field. The QWRD80G611 portable FMCW radar level gauge brings laboratory-grade ...

Quality Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay factory

Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay

Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.

Quality Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement factory

Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement

Universal Gauge Pressure Transmitter for Oil, Water and Gas 1. Why You Need a Gauge Pressure Transmitter Most industrial pressure measurements — pump discharge, line pressure, tank head, filter differential — are expressed relative to the surrounding atmosphere. A gauge pressure transmitter reads ...

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.