Absolute Pressure Transducer 24VDC Industrial Temperature Transmitter
Product Details
| Input Power: | 24vdc | Warranty: | 1 Year |
|---|---|---|---|
| Connection: | CL150(DN25) | Pressure Type: | Gauge, Absolute, Sealed Gauge |
| Communication Protocol: | HART, Modbus, Profibus | Electrical Connection: | M12 Connector |
| Application: | Industrial Automation, HVAC, Hydraulic Systems | Pressure Medium: | Gas Or Liquid |
| Process Connection: | 1/4 Inch NPT | Signal Output: | 4-20mA 2 Wires |
| Highlight |
Absolute Pressure Transducer,Pressure Transducer 24vdc,Industrial Pressure Temperature Transmitter |
||
Product Description
Absolute Pressure Transducer for Industrial Automation and HVAC
1. Why You Need It
Absolute pressure measurement is essential whenever the process must be referenced to a stable vacuum, not the shifting local atmosphere. In HVAC systems, hydraulic circuits and industrial automation, atmospheric changes would otherwise corrupt a gauge reading. This absolute pressure transducer measures true absolute pressure and communicates it over HART, Modbus or Profibus, giving engineers a stable, multi-protocol pressure signal that integrates with modern control systems and stays accurate regardless of weather or altitude.
2. Working Principle
The transducer uses a sensing element with a sealed vacuum reference. Process pressure acts on one side of the diaphragm while the reference side is permanently evacuated, so the deflection is proportional to absolute pressure. The sensor converts this deflection into a 4-20 mA signal, and the onboard electronics add HART, Modbus or Profibus digital communication. Because the reference vacuum is sealed and stable, the measurement does not drift with ambient pressure changes.
3. Key Advantages
- True absolute pressure measurement
- HART, Modbus and Profibus protocols
- Gauge / absolute / sealed gauge
- 4-20 mA 2-wire output
- 24 V DC power supply
- 1/4 inch NPT process connection
- M12 electrical connection
- CL150 (DN25) option
- Suitable for gas and liquid media
- Stable, drift-free reference
Common Pain Points & Solutions
| Problem | Conventional Issue | Our Solution | Result |
|---|---|---|---|
| Atmospheric drift errors | Gauge sensors drift with weather | Sealed vacuum reference | True absolute, no drift |
| Multi-protocol plant integration | Single-protocol limits | HART / Modbus / Profibus | Fits any control system |
| HVAC / hydraulic accuracy | Inaccurate sensors cause issues | Stable absolute measurement | Reliable system control |
| Altitude / weather shifts | Gauge zero shifts | Fixed vacuum reference | Consistent reading everywhere |
Application Cases
Application: Building air / refrigerant pressure
Medium: Air / refrigerant
Pressure Range: 0-1.0 MPa
Operating Temperature: -20 to 60 °C
Installation Environment: Mechanical room
Customer Challenge: Stable pressure for HVAC control
Previous Problem: Gauge drift with weather
Solution: Absolute transducer, Modbus
Installation Location: Chiller / air handler
Result: Stable HVAC control
Application: Hydraulic system pressure
Medium: Hydraulic oil
Pressure Range: 0-30 MPa
Operating Temperature: 10-80 °C
Installation Environment: Machine / hydraulic unit
Customer Challenge: Reliable pressure for control
Previous Problem: Sensor drift
Solution: Absolute transducer, 4-20 mA
Installation Location: Hydraulic manifold
Result: Reliable hydraulic control
Application: Process pressure monitoring
Medium: Process gas / liquid
Pressure Range: 0-10 MPa
Operating Temperature: 10-100 °C
Installation Environment: Plant floor
Customer Challenge: Multi-protocol integration
Previous Problem: Protocol mismatch
Solution: HART/Profibus transducer
Installation Location: Process line
Result: Seamless DCS integration
Application: Pump / line pressure
Medium: Water
Pressure Range: 0-1.6 MPa
Operating Temperature: 5-40 °C
Installation Environment: Pump station
Customer Challenge: Stable pressure data
Previous Problem: Altitude-affected gauge
Solution: Absolute transducer, 1/4 NPT
Installation Location: Pump discharge
Result: Consistent pressure reading
Technical Specifications
| Specification | Value |
|---|---|
| Pressure Type | Gauge / Absolute / Sealed Gauge |
| Communication | HART / Modbus / Profibus |
| Output | 4-20 mA (2-wire) |
| Power Supply | 24 V DC |
| Process Connection | 1/4 inch NPT |
| Connection Option | CL150 (DN25) |
| Electrical Connection | M12 |
| Media | Gas / liquid |
FAQ
Q: What is an absolute pressure transducer?
An absolute pressure transducer measures pressure relative to a sealed internal vacuum, so its reading is true absolute pressure. Unlike gauge sensors that reference the surrounding atmosphere, an absolute transducer's zero point never shifts with weather or altitude. This makes it essential for HVAC, hydraulic and automation applications where a stable, atmosphere-independent pressure reading is required.
Q: What protocols does it support?
The transducer supports HART, Modbus and Profibus digital communication in addition to the 4-20 mA analog signal. This multi-protocol support lets the same instrument connect to a wide range of PLC, DCS and SCADA systems, simplifying integration and reducing the number of variants that need to be stocked.
Q: What pressure types are available?
It offers gauge, absolute and sealed gauge pressure types. Gauge references atmosphere, absolute references a sealed vacuum, and sealed gauge uses a fixed internal reference. The choice depends on whether the application needs a true absolute reading or a simpler gauge reference.
Q: What is the output signal?
The output is a standard 4-20 mA two-wire signal, which connects directly to PLC, DCS and SCADA inputs. The two-wire loop simplifies wiring and allows long cable runs without signal degradation, while the digital protocol overlays on the same loop for configuration and diagnostics.
Q: What power supply does it need?
It operates on a 24 V DC supply, the standard for industrial instrumentation. The low-voltage DC supply is safe and integrates with standard control panels and power supplies used in automation and HVAC systems.
Q: What process connection does it use?
The standard process connection is 1/4 inch NPT, with a CL150 (DN25) flanged option available. The threaded connection suits most HVAC, hydraulic and process lines, while the flange option is used where a larger, more secure connection to the vessel or pipe is required.
Q: What media can it measure?
It measures gas and liquid media compatible with the wetted materials. Typical media include air, refrigerant, water, hydraulic oil and process gases. For aggressive media, the wetted material compatibility should be verified before selection.
Q: How does it differ from a gauge pressure transducer?
A gauge pressure transducer measures relative to ambient atmosphere, so its zero shifts with weather and altitude. An absolute pressure transducer measures relative to a sealed vacuum, so its zero is fixed. For applications where a true, stable pressure reference is needed, the absolute transducer is required.
Q: Why is a stable reference important?
A stable reference ensures the pressure reading reflects only the process, not environmental changes. In HVAC control, hydraulic systems and automation, a drifting zero causes control errors and inefficiency. The sealed vacuum reference eliminates this source of error, providing consistent, repeatable measurement.
Q: Where is it used?
It is used in HVAC systems, hydraulic circuits, industrial automation, water treatment and any application needing a stable absolute pressure measurement with multi-protocol communication. Its combination of true absolute sensing and HART/Modbus/Profibus support makes it a versatile choice for modern plants.
Product Highlights
Absolute Pressure Transducer for Industrial Automation and HVAC 1. Why You Need It Absolute pressure measurement is essential whenever the process must be referenced to a stable vacuum, not the shifting local atmosphere. In HVAC systems, hydraulic circuits and industrial automation, atmospheric ...
Petroleum Radar Level Gauge 26GHz High Temperature Industrial
Petroleum Radar Level Gauge for High-Temperature Industrial Tank Measurement Oil storage is a high-stakes business: every millimeter of level represents valuable product, and every measurement error becomes an inventory loss or a safety risk. The QWRD80G603 petroleum radar level gauge brings 26GHz ...
Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor
Portable FMCW Radar Level Gauge for Quick, Accurate Liquid Measurement Anywhere Sometimes you do not need a permanently installed instrument; you need a reliable level reading here, now, at any tank in the plant or in the field. The QWRD80G611 portable FMCW radar level gauge brings laboratory-grade ...
Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay
Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.
Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement
Universal Gauge Pressure Transmitter for Oil, Water and Gas 1. Why You Need a Gauge Pressure Transmitter Most industrial pressure measurements — pump discharge, line pressure, tank head, filter differential — are expressed relative to the surrounding atmosphere. A gauge pressure transmitter reads ...
Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.