Differential Pressure Transmitter Sealed Gauge 15vdc-30vdc HART Output
Product Details
| Warranty: | 1 Year | Pressure Type: | Gauge, Absolute, Sealed Gauge |
|---|---|---|---|
| Communication Protocol: | HART, Modbus, Profibus | Pressure Medium: | Gas Or Liquid |
| Range: | 0-0.1kPa ~ 3MPa | Voltage: | 5±0.5VDc |
| Power: | 5VDC /24VDC /15-30vdc | Input Power: | 24vdc |
| Bridge Impedance: | 11KΩ±30% | Output: | 4~20mA,0~5V,0~10V,RS485 |
| Highlight |
Sealed Gauge Pressure Transducer,Pressure Differential Transmitter 15vdc,Pressure Differential Transmitter 30vdc |
||
Product Description
Sealed Gauge Differential Pressure Transmitter with Multi-Protocol Output
1. Why You Need a Sealed Gauge Transmitter
Not every measurement should be referenced to the local atmosphere. In sealed systems, high-altitude installations or applications where humidity and contaminants would enter an open vent, a sealed gauge transmitter provides a fixed, hermetically sealed reference so the reading is stable and protected from the environment. By offering gauge, absolute and sealed gauge configurations in a single platform, this instrument lets one transmitter serve diverse measurement needs — from general process pressure to precise low-range differential measurement — with flexible digital communication to match any control system.
2. Working Principle of the Sealed Gauge Transmitter
The transmitter measures pressure using a sealed reference: in sealed gauge mode, the reference chamber is hermetically sealed at a fixed pressure, protecting the sensor from humidity and contamination while providing a stable baseline. In gauge mode it references atmosphere, and in absolute mode it references a vacuum. The sensor converts the measured pressure into an electrical signal, which is output as 4-20 mA, 0-5 V, 0-10 V or RS485, with HART, Modbus or Profibus digital communication layered on top for configuration and diagnostics.
3. Sealed Gauge Design Advantages
- Sealed reference protection: hermetically sealed chamber resists humidity and contamination.
- Three measurement types: gauge, absolute and sealed gauge in one platform.
- Multi-protocol communication: HART, Modbus and Profibus options.
- Wide range: from 0-0.1 kPa to 3 MPa covers low to medium pressures.
- Flexible outputs: 4-20 mA, 0-5 V, 0-10 V and RS485.
Common Measurement Challenges & Solutions
| 客户工况问题 | 传统方案问题 | 我们的解决方案 | 最终收益 |
|---|---|---|---|
| Humidity / contamination in vent | Open vent lets moisture damage sensor | Hermetically sealed reference chamber | Protected, stable measurement |
| High-altitude / sealed systems | Gauge reference drifts with atmosphere | Sealed gauge reference option | Stable reading independent of ambient |
| Multiple reference needs | Separate instruments per type | Gauge / absolute / sealed gauge in one | Fewer models, simpler sourcing |
| Diverse control systems | Single-protocol limits integration | HART, Modbus, Profibus options | Compatibility with any system |
Application: Duct / differential pressure
Medium: Air
Pressure Range: 0-0.5 kPa
Operating Temperature: 0-50 °C
Installation Environment: Ductwork
Customer Challenge: Low-range differential measurement
Previous Problem: Insufficient low-pressure resolution
Solution: Low-range differential transmitter with RS485
Installation Location: Duct pressure taps
Result: Accurate airflow / filter monitoring
Application: Filter / level differential
Medium: Water
Pressure Range: 0-0.1 MPa
Operating Temperature: 0-40 °C
Installation Environment: Plant, humid
Customer Challenge: Humidity damage to open-vent sensors
Previous Problem: Sensor failure from moisture
Solution: Sealed gauge transmitter
Installation Location: Filter differential taps
Result: Reliable measurement despite humidity
Application: Sealed vessel pressure
Medium: Process fluid
Pressure Range: 0-3 MPa
Operating Temperature: 10-80 °C
Installation Environment: Process area
Customer Challenge: Stable pressure in sealed system
Previous Problem: Ambient drift affected readings
Solution: Sealed gauge transmitter with HART
Installation Location: Vessel pressure tap
Result: Stable, protected measurement
Application: Multi-point pressure monitoring
Medium: Air, liquid
Pressure Range: 0-1 MPa
Operating Temperature: 0-60 °C
Installation Environment: Machine / process
Customer Challenge: Integrate with diverse systems
Previous Problem: Protocol mismatch
Solution: Multi-protocol (HART/Modbus/Profibus) transmitter
Installation Location: Process points
Result: Easy integration with any control system
Why Choose Our Sealed Gauge Pressure Transmitter?
- Gauge, absolute and sealed gauge measurement types
- Hermetically sealed reference resists humidity and contamination
- HART, Modbus and Profibus communication options
- 4-20 mA, 0-5 V, 0-10 V and RS485 outputs
- Wide 0-0.1 kPa to 3 MPa measurement range
- Suitable for low-range differential measurement
- 15-30 V DC power supply
- Stable reference for high-altitude and sealed systems
- Multi-point networking via RS485
- Flexible single-platform configuration
| Technical Specification | Value |
|---|---|
| Measurement Range | 0 - 0.1 kPa to 3 MPa |
| Accuracy | High precision (industrial) |
| Output Signal | 4-20 mA, 0-5 V, 0-10 V, RS485 |
| Process Connection | Configurable |
| Wetted Material | Stainless steel |
| Operating Temperature | Industrial range |
| Pressure Reference | Gauge / absolute / sealed gauge |
| Protection Grade | Industrial grade |
Q: What is a sealed gauge pressure transmitter?
A sealed gauge pressure transmitter measures pressure relative to a fixed, hermetically sealed reference pressure rather than open atmospheric pressure. The sealed chamber protects the sensor from humidity, dust and contamination that would enter an open vent, while providing a stable baseline for measurement. Sealed gauge is used in high-altitude installations, sealed systems and humid environments where an open atmospheric vent would cause drift or sensor damage.
Q: What is the difference between sealed gauge and gauge pressure?
Gauge pressure is referenced to the open, local atmosphere, so the reading changes with weather and altitude, and the vent can admit moisture and contaminants. Sealed gauge pressure is referenced to a fixed, hermetically sealed chamber, protecting the sensor from the environment and providing a stable reference independent of immediate atmospheric changes. Sealed gauge is preferred in humid, dirty or sealed-system applications where an open vent is undesirable.
Q: What is the difference between gauge, absolute and differential pressure?
Gauge pressure is measured relative to local atmospheric pressure, absolute pressure relative to a perfect vacuum, and differential pressure as the difference between two pressure points. This transmitter supports all three configurations, allowing one platform to serve different measurement references. The choice depends on whether the process needs a reading relative to ambient (gauge), independent of ambient (absolute), or the difference between two taps (differential).
Q: What communication protocols are supported?
The transmitter supports HART, Modbus and Profibus digital communication protocols. HART superimposes digital data on the 4-20 mA analog signal for configuration and diagnostics. Modbus RTU over RS485 enables multi-drop digital networking with PLCs and SCADA. Profibus is a fieldbus standard used in many European industrial systems. This multi-protocol support ensures compatibility with a wide range of control systems.
Q: What output signals are available?
The transmitter provides 4-20 mA analog, 0-5 V and 0-10 V voltage, and RS485 digital outputs. The 4-20 mA loop is the standard for long cable runs and PLC/DCS inputs, voltage outputs suit systems preferring voltage signals, and RS485 enables digital multi-drop communication. This flexibility allows the transmitter to integrate with virtually any control or monitoring system.
Q: What is the measurement range?
The transmitter covers a wide measurement range from 0-0.1 kPa to 3 MPa, spanning low-range differential measurements (such as HVAC duct pressure) to medium-range process pressure. The wide span coverage makes it versatile for air-flow, filter differential, level and general pressure applications. The specific range is configured to match the application's operating pressure for best accuracy.
Q: Why use a sealed reference instead of an open vent?
A sealed reference protects the sensor from humidity, dust and corrosive gases that an open atmospheric vent would admit, and it provides a stable baseline independent of immediate atmospheric fluctuations. In humid environments, an open vent allows moisture to condense inside and damage the electronics; in high-altitude or sealed systems, the open reference would drift with ambient pressure. A sealed reference eliminates these problems for more reliable measurement.
Q: Can it measure low differential pressure?
Yes. The transmitter's range extends down to 0-0.1 kPa, enabling precise low-range differential measurement for applications such as HVAC duct pressure, cleanroom differential and filter monitoring. Low-range differential measurement requires a sensitive, stable sensor, and the sealed reference helps maintain accuracy at these small spans. This capability makes the transmitter suitable for both process and building-automation applications.
Q: What power supply does it need?
The transmitter operates on a 15-30 V DC power supply, compatible with standard industrial power systems. The two-wire 4-20 mA version draws power from the signal loop, while RS485 and voltage-output versions require a separate supply. The specified range provides flexibility for field and panel installations using common 24 V DC supplies.
Q: Where are sealed gauge transmitters used?
Sealed gauge transmitters are used in HVAC duct and differential pressure measurement, water and environmental filter monitoring, sealed process vessels, and automation systems requiring flexible protocol integration. They are particularly valuable in humid, dirty or high-altitude environments where an open atmospheric vent would compromise reliability, and in plants with diverse control systems needing multi-protocol support.
Product Highlights
Sealed Gauge Differential Pressure Transmitter with Multi-Protocol Output 1. Why You Need a Sealed Gauge Transmitter Not every measurement should be referenced to the local atmosphere. In sealed systems, high-altitude installations or applications where humidity and contaminants would enter an open ...
Petroleum Radar Level Gauge 26GHz High Temperature Industrial
Petroleum Radar Level Gauge for High-Temperature Industrial Tank Measurement Oil storage is a high-stakes business: every millimeter of level represents valuable product, and every measurement error becomes an inventory loss or a safety risk. The QWRD80G603 petroleum radar level gauge brings 26GHz ...
Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor
Portable FMCW Radar Level Gauge for Quick, Accurate Liquid Measurement Anywhere Sometimes you do not need a permanently installed instrument; you need a reliable level reading here, now, at any tank in the plant or in the field. The QWRD80G611 portable FMCW radar level gauge brings laboratory-grade ...
Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay
Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.
Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement
Universal Gauge Pressure Transmitter for Oil, Water and Gas 1. Why You Need a Gauge Pressure Transmitter Most industrial pressure measurements — pump discharge, line pressure, tank head, filter differential — are expressed relative to the surrounding atmosphere. A gauge pressure transmitter reads ...
Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.