Quality Ultrasonic Cross Correlation Flowmeter Clamp-On Non-Invasive factory
<
Quality Ultrasonic Cross Correlation Flowmeter Clamp-On Non-Invasive factory
Quality Ultrasonic Cross Correlation Flowmeter Clamp-On Non-Invasive factory
Quality Ultrasonic Cross Correlation Flowmeter Clamp-On Non-Invasive factory
Quality Ultrasonic Cross Correlation Flowmeter Clamp-On Non-Invasive factory
>

Ultrasonic Cross Correlation Flowmeter Clamp-On Non-Invasive

Brand Name: QINWEIYB
Model Number: QWLW-GY209
Place of Origin: China
Minimum Order Quantity: 1Set
Price: Negotiable
Supply Ability: 100PCS/Month

Product Details


Medium: Liquid, Water, Oil Pipe Material: Carbon Steel,stainless Steel,PVC.
Pipe Size: Clamp-on:1"~48"(25mm~1200mm) Transducer Cable: Standard Cable Length:16ft(5m).
Pipe Size Compatibility: 15 Mm To 6000 Mm Power Supply: 24 V DC Or 110/220 V AC
Flow Range: 0.01 To 40 M/s Enclosure Rating: IP65 Or Higher
Highlight

Ultrasonic Cross Correlation Flow Meter

,

Clamp On Ultrasonic Flow Meter

,

Clamp On Flow Meter Ultrasonic

Product Description

Applicable To Extremely Complex Medium Correlation Method Ultrasonic Flowmeter

Correlation method ultrasonic flowmeter is a type of ultrasonic flowmeter based on the principle of "cross-correlation analysis".

Core Features
  1. Unaffected by changes in sound speed: This is its greatest advantage. It measures the transmission time of the "pattern" and does not rely on the absolute sound speed of ultrasonic waves in a stationary fluid. Therefore, it is completely unaffected by changes in sound speed caused by variations in fluid composition, temperature, and pressure, ensuring extremely high and stable accuracy.
  2. Applicable to extremely complex media: It can measure almost any heterogeneous fluid, including high-concentration slurries, gas-liquid two-phase flows, liquid-solid two-phase flows, non-Newtonian fluids, viscous liquids, etc. As long as there are detectable random disturbances in the fluid.
  3. Excellent linearity: The flow rate has a strict inverse relationship with the transmission time, resulting in very good measurement linearity.
  4. No moving parts, non-contact/low-contact.
Comparison with the Mainstream "Time Difference Method"
Characteristics Related Method Ultrasonic Flowmeter Time Difference Method Ultrasonic Flowmeter
Measurement Object The transmission time of "randomly marked patterns" in the fluid. The propagation time difference of the ultrasonic "wave" itself.
Dependence on Sound Speed Completely independent, immune in principle. Highly dependent, requires precise measurement and compensation for sound speed changes.
Applicable Medium Non-homogeneous, complex multiphase flows (slurries, gas-liquid mixtures, etc.). Relatively homogeneous, clean single-phase fluids (water, oil, gas).
Accuracy Influencing Factors Primarily affected by the accuracy of the sensor spacing L and signal quality. Affected by multiple factors such as sound speed changes, flow profile, and installation angle.
Cost and Complexity High. Moderate (single-channel) to high (multi-channel).
Typical Accuracy Can reach ±0.5% to ±1.0% (under applicable media). Can reach ±0.5% or even higher in clean fluids.
Response Time Slow (seconds). Fast (milliseconds to seconds).
Typical application scenarios
  1. Mining and metallurgy: Flow measurement of high-concentration ore pulp, tailings pulp, cement slurry, and coal-water mixtures.
  2. Oil and energy: Measurement of three-phase oil, gas, and water flow, heavy oil, and well production fluids.
  3. Chemical and papermaking: Pulp, cellulose pulp, polymer solutions, and high-viscosity chemical raw materials.
  4. Wastewater treatment: Flow control of high-solid-content sludge and digested sludge.
  5. Research and special industries: Complex fluid dynamics research such as fluidized beds, pneumatic conveying, and food slurries.

Correlation ultrasonic flowmeters are the "specialist experts" and "problem solvers" in the field of flow measurement. They bypass the theoretical bottleneck of traditional ultrasonic flowmeters (speed of sound dependency) and take a unique approach by using the "fingerprint" of the fluid itself for measurement.

Product Highlights

Applicable To Extremely Complex Medium Correlation Method Ultrasonic Flowmeter Correlation method ultrasonic flowmeter is a type of ultrasonic flowmeter based on the principle of "cross-correlation analysis". Core Features Unaffected by changes in sound speed: This is its greatest advantage. It ...

Related Products
Quality Petroleum Radar Level Gauge 26GHz High Temperature Industrial factory

Petroleum Radar Level Gauge 26GHz High Temperature Industrial

Petroleum Radar Level Gauge for High-Temperature Industrial Tank Measurement Oil storage is a high-stakes business: every millimeter of level represents valuable product, and every measurement error becomes an inventory loss or a safety risk. The QWRD80G603 petroleum radar level gauge brings 26GHz ...

Quality Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor factory

Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor

Portable FMCW Radar Level Gauge for Quick, Accurate Liquid Measurement Anywhere Sometimes you do not need a permanently installed instrument; you need a reliable level reading here, now, at any tank in the plant or in the field. The QWRD80G611 portable FMCW radar level gauge brings laboratory-grade ...

Quality Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay factory

Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay

Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.

Quality Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement factory

Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement

Universal Gauge Pressure Transmitter for Oil, Water and Gas 1. Why You Need a Gauge Pressure Transmitter Most industrial pressure measurements — pump discharge, line pressure, tank head, filter differential — are expressed relative to the surrounding atmosphere. A gauge pressure transmitter reads ...

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.