Quality Non-Contact Radar Level Gauge High Precision Anti-Interference factory
<
Quality Non-Contact Radar Level Gauge High Precision Anti-Interference factory
Quality Non-Contact Radar Level Gauge High Precision Anti-Interference factory
Quality Non-Contact Radar Level Gauge High Precision Anti-Interference factory
Quality Non-Contact Radar Level Gauge High Precision Anti-Interference factory
>

Non-Contact Radar Level Gauge High Precision Anti-Interference

Brand Name: QINWEIYB
Model Number: QWRD80G616
Place of Origin: China
Minimum Order Quantity: 1Set
Supply Ability: 100PCS/Month

Product Details


Material Of Sensor: PVC Or PTFE Resolution: 1mm
Connection: Bluetooth/NB-iot/4G Outputsignal: 4-20 MA / HART / Modbus
Protectionrating: IP67 / IP68 Process Connection: Flange From DN80
Process Pressure: (-0.1~0.1)MPa Accurancy: ±1mm
Measurementrange: 0.3 To 70 Meters Display: LCD With Backlight
Highlight

non-contact radar level gauge

,

high precision radar level gauge

,

anti-interference radar level gauge

Product Description

Non-Contact Radar Level Gauge with Millimeter Precision and Strong Anti-Interference

Plants need level data that is precise, stable and available across every medium they handle. This non-contact radar level gauge delivers millimeter-level accuracy, long-term stability and strong anti-interference, measuring liquids, slurries and granular materials through temperature, pressure, steam, dust and foam with multiple antenna options to match the application.

Why Do You Need a High-Precision Non-Contact Radar Level Gauge?

Measurement quality decides process quality: inventory accuracy, control stability and safety margins all depend on how precisely and reliably the level is known. Many plants still struggle with instruments that drift, lose the echo in steam or dust, or require constant maintenance because they touch the medium. A high-precision non-contact radar gauge addresses all of these: its millimeter-level accuracy, typically ±3mm, supports tight process control and accurate inventory; its non-contact principle eliminates wear, corrosion, coating and contamination; and its strong anti-interference performance keeps readings stable through temperature changes, pressure variations, steam, dust, inert gases and foam that disturb other technologies. The emitted microwave energy is extremely low, posing no hazard to personnel or products, and the long-term stability means the calibration holds for years. For plants that measure many media in demanding conditions, this gauge is the dependable foundation of process measurement.

Working Principle: Non-Contact Microwave Reflection with Application-Matched Antenna

The gauge transmits low-energy microwave pulses from its antenna toward the product surface; the pulses reflect at the surface and return to the antenna, and the electronics measure the round-trip time to calculate the distance and level with millimeter precision. Because the measurement is non-contact, no part of the instrument touches the medium, and because microwaves are electromagnetic waves, the reading is almost unaffected by temperature, pressure, steam, dust, inert gases and foam. The gauge is available with multiple antenna forms, including horn and parabolic types, and multiple installation methods, so the beam can be matched to the application: horn antennas for general liquids and solids, parabolic antennas for long ranges and weak reflections. For low dielectric constant media, the antenna and processing are selected with care to ensure a reliable echo, and the installation position is chosen to avoid interference from materials and pipelines.

Structural Advantages of the Non-Contact Gauge

  • Millimeter precision: typically ±3mm accuracy for control and inventory.
  • Non-contact measurement: no wear, corrosion, coating or contamination.
  • Strong anti-interference: stable through steam, dust, foam and gases.
  • Horn and parabolic antennas: match beam to application.
  • Multiple installation methods: flexible mounting options.
  • Long-term stability: calibration holds over years of service.
  • Low emission energy: safe for personnel and products.
  • Multi-media capability: liquids, slurries, granular materials.

Pain Point Analysis: 4 Challenging Working Conditions

Working ConditionTypical FailureWhy Contact / Ultrasonic FailNon-Contact Radar Solution
Steam and vapor above the surfaceEcho loss, false readingsUltrasonic scattered by vaporMicrowaves penetrate steam
Dusty silos and solids handlingSignal attenuationDust blocks sound wavesRadar immune to dust
Foam layers on liquidsFalse level indicationFoam absorbs signalsRadar processing identifies surface
Corrosive and coating mediaSensor destruction, driftContact probes attackedNon-contact, nothing wetted

Application Cases

Case 1 - Chemical Storage Tank Inventory

Industry: Chemical manufacturing

Application: Precise inventory monitoring of chemical storage

Measured Medium: Liquid chemicals

Range: 0-15 m

Process Temperature: -10 to +80 °C

Output Signal: 4-20 mA + HART to inventory system

Key Challenge: Corrosive vapor and coating media

Configuration: Horn antenna version, flange connection

Installation: Top mounted on tank

Performance Result: Stable millimeter-level readings, no coating

Case 2 - Slurry and Solids Vessel

Industry: Mining and minerals

Application: Level monitoring of slurry and granular storage

Measured Medium: Slurries, granular materials

Range: 0-20 m

Process Temperature: 0-60 °C

Output Signal: 4-20 mA to process control

Key Challenge: Dust and uneven solid surface

Configuration: Parabolic antenna for long range

Installation: Top mounted over vessel

Performance Result: Reliable readings through dust

Product Advantages

  • Millimeter-level precision (±3mm typical)
  • Non-contact, nothing touches the medium
  • Strong anti-interference performance
  • Horn and parabolic antenna options
  • Multiple installation methods
  • Long-term stability, low drift
  • Extremely low emission energy, safe
  • Measures liquids, slurries and solids

Technical Parameters

ParameterSpecification
AccuracyMillimeter level (typically ±3 mm)
Antenna OptionsHorn / parabolic
MediaLiquids, slurries, granular materials
Environment ImmunityTemperature, pressure, steam, dust, foam
Output Signal4-20 mA / HART
SafetyExtremely low emission energy

SEO FAQ

Q1: How accurate is this non-contact radar level gauge?

The gauge provides millimeter-level accuracy, typically ±3mm, which is maintained across its measuring range through high-frequency radar signal processing. On a 15-meter tank, this means the level value is dependable to a few millimeters, sufficient for tight process control, accurate inventory accounting and reliable high/low alarming. The accuracy is combined with long-term stability: because the measurement is non-contact and the electronics are solid-state, the calibration holds over years of service with minimal drift. This combination of precision and stability is what makes the gauge suitable both for process control, where repeatability matters, and for inventory management, where absolute accuracy matters.

Q2: What makes it resistant to interference?

Several design factors combine for strong anti-interference performance. First, the non-contact microwave principle is inherently immune to the conditions that disturb other technologies: electromagnetic waves travel through steam, dust, inert gases and foam with minimal attenuation, unlike sound waves which are scattered. Second, the antenna is selected to match the application, so the beam is focused on the surface and avoids false echoes from vessel walls and structures. Third, the signal processing evaluates the echo intelligently, distinguishing the true surface reflection from noise. This layered approach keeps readings stable in dusty silos, steaming vessels, foaming tanks and environments with changing temperature and pressure.

Q3: Which antenna should I choose: horn or parabolic?

The choice depends on your application. Horn antennas are the general-purpose option, providing a well-defined beam and reliable echoes for most liquids, slurries and solids at typical industrial ranges; they are compact, robust and suitable for the majority of tanks and vessels. Parabolic antennas focus the signal into a narrower, more powerful beam, which is advantageous for long ranges, weak reflections and low dielectric media, where maximum signal concentration is needed to secure a usable echo. If your vessel is tall, your medium reflects weakly, or you have experienced echo problems, the parabolic option is the right choice. Our engineers can recommend the antenna based on your range, media and vessel geometry.

Q4: Can it measure low dielectric constant media?

Yes, with appropriate selection. Low dielectric constant media, such as light hydrocarbons and some solvents, reflect microwave energy weakly, so the antenna and signal processing must be chosen carefully to secure a reliable echo. For these applications, we recommend the antenna configuration that concentrates the most energy on the surface, such as a parabolic antenna, and the signal processing is set up with an appropriate threshold and gain. The installation position should also avoid interference from materials and pipelines that could create false echoes. When ordering, specify the medium and its dielectric properties so our engineers can configure the gauge correctly for dependable measurement.

Q5: What support and customization do you offer?

As the manufacturer, we provide direct technical support including antenna selection, installation position advice, configuration and troubleshooting. Customization options include measuring range, antenna form (horn or parabolic), process connection, output protocol, housing options, labeling and packaging, plus OEM and ODM programs. Every gauge is factory-calibrated and tested before shipment, and our engineers can review your media, vessel dimensions and environmental conditions to specify the correct configuration. Contact us with your application details for a tailored recommendation and quotation.

Why Choose Our Non-Contact Radar Level Gauge?

Precision that holds, performance that ignores the environment, and a design that never touches your product: this non-contact radar level gauge delivers millimeter-level accuracy with strong anti-interference across liquids, slurries and solids. Horn and parabolic antennas match the beam to your application, multiple mounting options fit your vessel, and extremely low emission energy keeps the measurement safe. As the manufacturer, you receive factory calibration, application-matched configuration and direct engineering support. When your media is varied and your level must be exact, choose the non-contact radar that measures it all.

Product Highlights

Non-Contact Radar Level Gauge with Millimeter Precision and Strong Anti-Interference Plants need level data that is precise, stable and available across every medium they handle. This non-contact radar level gauge delivers millimeter-level accuracy, long-term stability and strong anti-interference, ...

Related Products
Quality Petroleum Radar Level Gauge 26GHz High Temperature Industrial factory

Petroleum Radar Level Gauge 26GHz High Temperature Industrial

Petroleum Radar Level Gauge for High-Temperature Industrial Tank Measurement Oil storage is a high-stakes business: every millimeter of level represents valuable product, and every measurement error becomes an inventory loss or a safety risk. The QWRD80G603 petroleum radar level gauge brings 26GHz ...

Quality Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor factory

Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor

Portable FMCW Radar Level Gauge for Quick, Accurate Liquid Measurement Anywhere Sometimes you do not need a permanently installed instrument; you need a reliable level reading here, now, at any tank in the plant or in the field. The QWRD80G611 portable FMCW radar level gauge brings laboratory-grade ...

Quality Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay factory

Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay

Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.

Quality Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement factory

Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement

Universal Gauge Pressure Transmitter for Oil, Water and Gas 1. Why You Need a Gauge Pressure Transmitter Most industrial pressure measurements — pump discharge, line pressure, tank head, filter differential — are expressed relative to the surrounding atmosphere. A gauge pressure transmitter reads ...

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.