Large Diameter Smart Water Meter DN50-DN300 Ultrasonic NB-IoT Remote Reading IP68
Product Details
| Meter Type: | Ultrasonic Large Diameter Smart Water Meter | Nominal Diameter: | DN50-DN300 |
|---|---|---|---|
| Measurement Principle: | Ultrasonic Transit-time, No Moving Parts | Accuracy Class: | Class 1 (±1%) |
| Flow Range: | 0.25-250 M3/h (DN100) | Communication: | NB-IoT, Optional RS485 / M-Bus |
| Battery Life: | 6 Years Minimum | Waterproof Rating: | IP68 |
| Body Material: | 304 Stainless Steel | Installation: | Horizontal Or Vertical, Flat Or Buried Pit |
| Highlight |
Ultrasonic Bulk Water Meter,NB-IoT Remote Reading Meter,DN50 DN300 Low Pressure Loss |
||
Product Description
Bulk water lines fail quietly. A single meters-off reading on a DN100 main can hide a leak that wastes thousands of cubic meters, and a worn mechanical register can under-bill an entire district for a year before anyone notices. The DN50-DN300 large diameter smart water meter replaces that blind spot with ultrasonic measurement, IP68 sealing and NB-IoT telemetry that reports every litre to your platform.
Utility companies and building owners do not lose money on domestic meters — they lose it on the big pipes. A DN150 main feeding a residential compound, a factory or a shopping centre carries thousands of cubic meters a month, so a one-percent metering error becomes a five-figure revenue gap each year. Traditional Woltmann and turbine bulk meters make this worse because their impellers wear, their head loss forces pumps to work harder, and their readings still depend on a person walking the line with a book.
Buyers choose an ultrasonic large diameter smart meter for four reasons. First, billing accuracy: ultrasonic transit-time sensing keeps accuracy stable without mechanical parts. Second, energy saving: the full-bore design removes the obstruction that throttles flow and raises pumping cost. Third, labour and data: NB-IoT uploads hourly readings to a cloud platform so no route reading is needed and outliers are flagged in real time. Fourth, revenue protection: event logs record reverse flow, empty pipe and tamper alarms, closing the loopholes that manual metering leaves open.
The meter sends ultrasonic pulses both with the flow and against it along a diagonal path inside the measuring tube. Because the sound travels faster downstream and slower upstream, the time difference between the two signals is directly proportional to the average flow velocity. Multiplied by the pipe cross-section, that velocity becomes volumetric flow, and integrated over time it becomes the total volume on the register. There are no impellers, no gears and no wetted moving parts, so accuracy does not drift with wear and the meter tolerates sand, grit and particles that would jam a mechanical bulk meter.
The measurement head then packages each reading through an NB-IoT module. Data is uploaded on a configurable interval — hourly, daily or event driven — to the operator platform, where consumption, reverse flow, burst flow and low battery are analysed automatically. A lithium battery sized for six or more years powers the whole unit, and the IP68 sealed body allows pit and buried installation without a separate enclosure.
Every structural choice is aimed at long-life accuracy in the field. The straight-through measuring tube gives a pressure loss close to that of straight pipe, cutting pumping energy. A 304 stainless steel body resists corrosion in soil and humid meter chambers, while the fully potted electronic module survives flooding. The detachable display lets the register be rotated for reading, and the sealed optical interface supports local configuration without breaking the IP68 barrier.
Because the sensing element does not touch a rotor, calibration stays stable across the whole flow range, from the low night-flow figures used in leak detection up to the peak demand of a plant. The meter keeps its accuracy in both directions, so backflow is metered and logged rather than silently ignored.
Start from the true peak and minimum flow of the line, not from the nominal pipe size alone. Confirm the pipe material, working pressure and whether the site can supply a stable NB-IoT signal. For flooded pits order the IP68 buried version; for indoor plant rooms the standard sealed version is enough. Keep ten upstream and five downstream diameters of straight pipe in front and behind the meter, install it horizontally with the arrow pointing in the flow direction, and leave room to reach the optical port for future servicing.
| Working Condition | Typical Failure of a Mechanical Bulk Meter | How the Ultrasonic Smart Meter Solves It |
|---|---|---|
| District mainline feeding residential compounds, where sand and grit are carried in the water | Impeller and gears wear, readings drift low, parts jam and head loss rises, so billing slips and pumps draw more power | No moving parts in the flow path; accuracy stays stable against wear and particles, and near-zero pressure loss keeps pumping energy low |
| Buried or pit-installed mains exposed to flooding, mud and seasonal temperature swings | Seals leak, water enters the register, fogging and short circuits end the reading, and route reading is impossible in wet seasons | IP68 fully potted electronics, stainless steel body and NB-IoT telemetry keep the meter working and reporting even when the pit is submerged |
- Ultrasonic transit-time sensing with no moving parts, so accuracy does not drift with wear
- Straight-through full-bore tube with near-zero pressure loss to save pumping energy
- NB-IoT remote reading with hourly data upload and cloud platform alarms
- IP68 fully potted body for flooded pits and buried installation
- Six-year lithium battery plus reverse-flow and empty-pipe event logging
- DN50 to DN300 range with 304 stainless steel body and rotatable sealed register
| Nominal Diameter | DN50 / DN80 / DN100 / DN150 / DN200 / DN250 / DN300 |
| Measurement Principle | Ultrasonic transit-time, no moving parts |
| Accuracy Class | Class 1 (±1%) over the full range |
| Flow Range (DN100) | 0.25 – 250 m³/h (Q3/Q1 = 400) |
| Communication | NB-IoT; optional RS485 / M-Bus |
| Battery Life | 6 years minimum under hourly upload |
| Waterproof Rating | IP68 |
| Body Material | 304 stainless steel (ductile iron optional) |
| Working Pressure | 1.6 MPa |
| Installation | Horizontal or vertical, flat / buried pit |
Q1: Why choose an ultrasonic large diameter water meter instead of a mechanical turbine bulk meter?
The decisive difference is what happens inside the pipe. A mechanical Woltmann or turbine meter measures by spinning a rotor in the flow, so sand, grit and normal wear gradually change its calibration and its pressure loss pushes up pumping cost. An ultrasonic meter fires sound pulses across the pipe instead. Because nothing obstructs the flow, head loss stays close to that of straight pipe, and because no rotor wears, accuracy remains stable for years. For mains that carry cloudy or particle-laden water, or that must balance a district meter area, that stability is what protects revenue. The ultrasonic design also meters reverse flow accurately and logs events, which mechanical registers simply cannot do.
Q2: How does NB-IoT remote reading change day-to-day operation?
NB-IoT removes the route-reading trip entirely and replaces it with a data stream. The meter uploads hourly or daily readings to the operator platform over licensed cellular spectrum, so coverage in pits and basements is far better than short-range radio. The platform then turns raw volume into decisions: minimum night-flow analysis exposes leaks, burst-flow alarms trigger immediate site checks, and reverse-flow or tamper events are time-stamped. Billing teams pull consumption without visiting the site, and maintenance teams act on exceptions rather than reading every meter. All of this runs on a battery designed for six years or more, so the operating cost is lower than a manual reading round as well as being more accurate.
Q3: Can the meter be installed in a submerged or buried meter pit?
Yes, provided you order the IP68 buried version. The electronics are fully potted and the body is sealed to survive temporary or permanent flooding, which is common in municipal valve chambers and roadside pits. The stainless steel housing resists the corrosion that humid chambers cause, and the optical interface lets you configure the meter on site without opening the seal. When specifying a buried installation, confirm the pin length and cable arrangement, and make sure the platform signal reaches the pit; NB-IoT usually does, but a quick coverage check at the site avoids surprises. For indoor plant rooms the standard sealed version is sufficient and cheaper.
Q4: What accuracy can I expect across the full flow range, and why does it matter?
The meter holds Class 1 accuracy, about ±1 percent, across its full range rather than only at the calibration point. This matters because a bulk main rarely runs at a single flow rate. It may surge at peak demand in the morning and then trickle at night, and a meter that is only accurate near its maximum will misread the low flows where leaks hide. Ultrasonic transit-time sensing keeps resolution high from the lowest measurable flow up to overload, and it does so in both directions. That wide, flat accuracy curve is what lets you trust night-flow leak analysis and reconcile district balances without constantly rechecking the meter.
Product Highlights
DN50-DN300 ultrasonic large diameter smart water meter with near-zero pressure loss, Class 1 accuracy and NB-IoT remote reading for municipal and commercial bulk metering.
Petroleum Radar Level Gauge 26GHz High Temperature Industrial
Petroleum Radar Level Gauge brings 26GHz radar precision and high-temperature capability to oil storage tank measurement. Every millimeter of level is tracked accurately to prevent inventory loss and safety risk. Inquire now for specifications.
Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor
Portable FMCW Radar Level Gauge brings laboratory-grade radar measurement to any tank in the plant or field. With IP67 protection and quick setup, it delivers accurate liquid level readings without permanent installation. Contact us for specifications.
Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay
Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.
Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement
Universal Gauge Pressure Transmitter measures pressure relative to the atmosphere for pump discharge, line pressure, tank head and filter differential applications. With 4-20mA output, it suits oil, water and gas measurement. Contact us for range options.
Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.