Electromagnetic Water Meter DN15-DN3000 No Moving Parts 4-20mA RS485 Industrial Sewage
Product Details
| Meter Type: | Electromagnetic Flow Meter | Nominal Diameter: | DN15-DN3000 |
|---|---|---|---|
| Measurement Principle: | Faraday Electromagnetic Induction | Liner Material: | Neoprene / F4 (PTFE) / PFA |
| Electrode Material: | 316L / Hastelloy C / Titanium | Accuracy: | ±0.5% Of Reading |
| Output Signal: | 4-20 MA, RS485 Modbus, HART, Pulse | Power Supply: | 220V AC / 24V DC / Battery |
| Protection: | IP65 / IP68 Remote Converter | Medium Conductivity: | ≥ 5 µS/cm |
| Highlight |
Electromagnetic Flow Meter,Sewage Wastewater Meter,PTFE Liner Hastelloy Electrode |
||
Product Description
Dirty, conductive and abrasive liquids destroy most flow meters. Sludge blinds a mechanical impeller, aggressive chemicals eat a rotor, and the moment the medium is anything other than clean water the reading becomes a guess. The electromagnetic water meter reads the liquid itself, with an unobstructed bore and no wetted moving parts, so it keeps working exactly where ordinary meters fail.
Once a flow line carries sewage, slurry, paper pulp, mining water or a chemical solution, mechanical metering stops being reliable. Solids clog the rotor, fibres wrap around the impeller, and abrasive particles grind the bearings away within months. The result is under-measurement, sudden failure and a maintenance bill that keeps repeating. Buyers also need a meter that tolerates a wide range of pipe sizes and materials, because plant and municipal networks mix DN15 dosing lines with DN1000 mains in the same system.
An electromagnetic flow meter answers these needs directly. Because it has no obstruction and nothing that rotates, solids pass straight through and there is no rotor to wear. Its wetted parts are selected for the medium, so a PTFE-lined body with Hastelloy electrodes handles aggressive chemicals while a rubber-lined body with stainless steel electrodes handles sewage and water. Purchase decisions usually hinge on three requirements: keep measuring in dirty media, survive aggressive chemistry, and integrate cleanly through 4-20 mA, RS485 or pulse outputs into the existing control system.
The meter applies Faraday's law of electromagnetic induction. A coil generates a magnetic field across the pipe, and as the conductive liquid flows through that field it acts like a moving conductor, producing a voltage across two electrodes mounted in the pipe wall. That induced voltage is directly proportional to the average flow velocity, so the converter can calculate volumetric flow from the pipe's known cross-section. There is nothing in the flow path to slow the liquid or to collect debris, which is why accuracy does not depend on the cleanliness of the medium.
Because the signal comes from the moving liquid itself, the meter needs the medium to conduct electricity. Most water, wastewater, slurries and aqueous chemicals qualify, and a simple conductivity check at the design stage confirms it. The converter then filters the small electrode signal, compensates for empty-pipe and noise conditions, and outputs a stable flow value, with totaliser and bi-directional measurement built in.
The unobstructed full bore gives the meter a pressure loss close to a straight pipe, which lowers pumping energy and allows it to be placed where a mechanical meter would starve the line. The liner isolates the metal body from the medium, and the electrode alloy is chosen for the specific chemistry, so one instrument platform serves water, sewage, pulp and chemical duty just by changing two components. The coils and electrodes are sealed behind the liner, so there are no crevices for solids to catch.
The design also scales gracefully. The same technology fits DN15 lab lines and DN3000 trunk mains, and the converter supports 4-20 mA, RS485 Modbus, HART and pulse outputs so the meter drops into PLC, SCADA and municipal telemetry systems without adapters. Zero-point stability and empty-pipe detection keep readings believable when the line runs partly full or drains down.
Match three things first: nominal diameter to the real working flow, liner material to the medium's chemistry, and electrode material to its corrosion profile. Confirm the medium's conductivity is high enough, choose a rubber liner for water and wastewater and a PTFE liner for acids and alkalis, and keep the meter flooded by installing it in a slightly rising section or a low point. Allow five diameters of upstream and three of downstream straight pipe, ground the sensor properly to the liquid, and mount the converter where it stays dry and readable, especially for buried installations with remote converters.
| Working Condition | Typical Failure of a Mechanical Meter | How the Electromagnetic Meter Solves It |
|---|---|---|
| Sewage, slurry and pulp lines carrying solids, fibres and grit | Impeller jams, fibres wrap the rotor, grit grinds the bearings, and the meter stops reading within weeks | Full-bore unobstructed path lets solids and fibres pass straight through with nothing to clog or wear |
| Aggressive chemical and process water lines | Reactive media corrode the rotor and housing, spurious changes in density spoil the reading | Chemically matched PTFE liner and Hastelloy electrodes isolate the metals, so only inert wetted parts touch the medium |
Case 1 — Municipal Wastewater Treatment Plant
| Industry | Wastewater treatment |
| Application | Influent and return sludge flow metering |
| Pipe Size | DN300 |
| Flow Range | 50 – 1800 m³/h |
| Communication | 4-20 mA and RS485 Modbus to plant SCADA |
| Key Challenge | Solids and grit that destroyed mechanical meters each season |
| Configuration | Rubber-lined sensor, stainless steel electrodes, IP68 remote converter |
| Installation | In a flooded channel with remote-mounted converter |
| Performance Result | Stable flow readings with no clogging through the full solids load |
| Customer Benefit | Reliable dosing control and accurate plant water balance |
Case 2 — Chemical Plant Process Water
| Industry | Chemical processing |
| Application | Dosing and dilution water measurement |
| Pipe Size | DN50 |
| Flow Range | 0.5 – 60 m³/h |
| Communication | HART and pulse output to the batch controller |
| Key Challenge | Corrosive and mildly aggressive dosing liquors |
| Configuration | PTFE liner, Hastelloy C electrodes, integrated converter |
| Installation | Vertical rising section to stay flooded |
| Performance Result | Accurate batch totals with no chemical attack on wetted parts |
| Customer Benefit | Lower chemical use and fewer unplanned meter replacements |
- Faraday-law electromagnetic sensing with a completely unobstructed bore
- No wetted moving parts, so the meter tolerates solids, fibres and grit
- Interchangeable liners and electrodes for water, wastewater and chemicals
- DN15 to DN3000 coverage from lab lines to trunk mains
- 4-20 mA, RS485 Modbus, HART and pulse outputs for easy system integration
- Bi-directional metering, empty-pipe detection and stable zero point
| Nominal Diameter | DN15 – DN3000 |
| Measurement Principle | Faraday electromagnetic induction |
| Liner Material | Neoprene / F4 (PTFE) / PFA |
| Electrode Material | 316L / Hastelloy C / Titanium / Tantalum |
| Accuracy | ±0.5% of reading (optional ±0.2%) |
| Output Signal | 4-20 mA, RS485 Modbus, HART, pulse |
| Power Supply | 220V AC / 24V DC / battery |
| Working Pressure | 1.6 MPa (up to 4.0 MPa on request) |
| Protection | IP65 / IP68 (remote converter options) |
| Medium Conductivity | ≥ 5 µS/cm |
Q1: What liquids can an electromagnetic water meter measure?Any liquid that conducts electricity and does not coat the electrodes can be measured. In practice that covers clean water, raw water, sewage, wastewater, sludge, paper pulp, mining slurry, and most aqueous acids, alkalis and salt solutions. The one hard requirement is conductivity: the medium should be at least about five microsiemens per centimetre, which ordinary water and wastewater easily exceed. Liquids that do not conduct, such as pure hydrocarbons, oils, solvents and deionised water, fall outside the measuring principle and need another technology. When specifying, confirm the conductivity at the design stage and match the liner and electrode materials to the chemistry so the meter has a long, stable service life.
Q2: How do I choose between a rubber liner and a PTFE liner?Choose by chemistry and temperature rather than by habit. A rubber liner such as neoprene suits water, wastewater, sewage and other neutral or mildly alkaline media, and it is the economical choice for most municipal and industrial duty. For acids, alkalis, oxidising chemicals and higher temperatures, a PTFE or PFA liner resists attack where rubber would swell or degrade. The electrode choice follows the same logic: 316L stainless steel is fine for water and wastewater, while Hastelloy C, titanium or tantalum handle aggressive or strongly corrosive media. If you tell us the medium, its concentration and its temperature, we will specify a liner and electrode combination that keeps the wetted parts inert for the whole service interval.
Q3: Can it be installed in a flooded pit or under the ground?Yes, with the correct protection ratings. The wetted sensor itself is fully sealed and can sit in a flooded chamber, and for these cases you order the remote-converter version so that only the sensor, rated IP68, is submerged while the electronics stay in a dry cabinet. A remote converter also keeps the display and programming keys accessible when the sensor is buried or mounted high in a service tunnel. Ground the sensor and the liquid properly, and route the cable so water cannot track into the terminal box. Many municipal wastewater plants and industrial sumps run electromagnetic meters permanently submerged on exactly this arrangement.
Q4: Why is accuracy so stable even with a dirty medium?Because the measurement does not depend on anything in the flow path moving or staying clean. The meter generates a magnetic field and reads the tiny voltage the conductive liquid produces as it moves through it, so the reading is tied to flow velocity rather than to the condition of a rotor or impeller. Solids, fibres and grit simply pass through the unobstructed bore without touching a measuring part, and there are no crevices for deposits to build up. As long as the electrodes remain in contact with the conductive liquid, accuracy stays at roughly ±0.5 percent of reading. That immunity to contamination is the core reason electromagnetic meters dominate sewage, slurry and pulp measurement.
Product Highlights
DN15-DN3000 electromagnetic water meter with an unobstructed bore for sewage, wastewater, slurry and chemical media, with selectable liners and 4-20 mA / RS485 output.
Petroleum Radar Level Gauge 26GHz High Temperature Industrial
Petroleum Radar Level Gauge brings 26GHz radar precision and high-temperature capability to oil storage tank measurement. Every millimeter of level is tracked accurately to prevent inventory loss and safety risk. Inquire now for specifications.
Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor
Portable FMCW Radar Level Gauge brings laboratory-grade radar measurement to any tank in the plant or field. With IP67 protection and quick setup, it delivers accurate liquid level readings without permanent installation. Contact us for specifications.
Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay
Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.
Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement
Universal Gauge Pressure Transmitter measures pressure relative to the atmosphere for pump discharge, line pressure, tank head and filter differential applications. With 4-20mA output, it suits oil, water and gas measurement. Contact us for range options.