Glass Tube Rotameter LZB-15 6-60 L/h Direct Reading Panel Mounted Dosing Flow Meter
Product Details
| Model: | QWYB-LZD511 (LZB-15) | Water Flow Range: | 6-60 L/h |
|---|---|---|---|
| Air Flow Range: | 0.1-1 M3/h At 20 C, 101.3 KPa | Accuracy Class: | 2.5 |
| Measuring Tube: | Borosilicate Glass 3.3 | Float Material: | 316L Stainless Steel, PTFE Or PVC Option |
| End Fitting Material: | PVC / Brass / SS304 | Process Connection: | 1/2 Inch Female Thread, NPT Or BSP |
| Max Working Pressure: | 0.6 MPa (PVC) / 1.0 MPa (stainless Steel) | Medium Temperature: | 0-60 C (PVC) / 0-120 C (stainless Steel) |
| Pressure Loss: | 2-3 KPa At Full Scale, Water | Installation: | Vertical Line, Flow Bottom To Top |
| Highlight |
Borosilicate Glass Measuring Tube,Direct Reading Small Flow Rotameter,Panel Mounted Dosing Flow Monitor |
||
Product Description
LZB-15 body | dual water / air scale | no power supply | class 2.5
If a dosing pump runs without a flow reference, the operator only learns that something is wrong when a tank test fails or a chemical bill jumps. This page explains where a transparent measuring tube earns its place on a small line, how the reading is produced, and how to keep the float matched to the liquid you are actually metering.
Metering pumps are set by stroke length and frequency, not by verified flow. Once the suction line draws air, a foot valve leaks, or a diaphragm starts to fatigue, the pump keeps stroking while the actual delivery falls. On a 6-60 L/h line that error is invisible: there is no pressure change worth noticing, no motor current signature, and no alarm. Operators then compensate by turning the stroke up, which usually makes the problem worse and pushes the chemical dose above the discharge permit limit.
A glass tube rotameter closes that gap for the price of a valve. The float position is a direct, physical statement about what is moving through the pipe right now, and it is readable from a metre away, in daylight, without a power supply, transmitter or hand-held device.
The tube is drawn with a slight internal taper, narrow at the bottom and wider at the top. Fluid entering from below lifts a shaped float until the upward drag of the moving liquid balances the weight of the float in that medium. Because the annular gap widens with height, each float position corresponds to exactly one flow rate, and the scale is engraved or printed against the tube.
Two practical consequences follow. First, the reading is density dependent: the same float sits lower in a heavier liquid, so the scale must match the medium. Second, the reading is volumetric and instantaneous, so a spike from a pulsating diaphragm pump shows up as a bobbing float. A small damping orifice or a short length of flexible hose upstream usually steadies the float enough to read.
- Water scale in L/h is engraved on the front of the tube, air scale in m3/h on the reverse side of the same scale strip.
- The float rotates slowly while measuring; a float that sits still or chatters is telling you about a blocked or surging line.
- Accuracy class 2.5 refers to the flow scale, so keep the working point between 30% and 90% of full scale where possible.
A metal tube float flowmeter resists pressure and temperature far better, but it hides the one thing an operator wants during commissioning: the medium itself. Glass shows bubbles, colour change, crystal formation and a sticking float in a single glance. On clean, low pressure dosing lines this visibility removes more faults than extra pressure rating ever will.
- Straight-through reading - no electronics, no display configuration, no 24 V loop to troubleshoot.
- Low pressure loss - 2-3 kPa at full scale on water, so gravity feed and low head circuits still work.
- Front access maintenance - the tube and float can be lifted out without cutting the pipe runs.
- Interchangeable float - swapping a 316L float for a PTFE one re-scales the same body for aggressive media.
- Panel or line mounting - the same body fits a skid panel or a wall bracket with two screws.
- Fast spare parts - tubes and floats are stocked separately, so a breakage is a same-week fix.
Most wrong readings on small rotameters come from ordering a water-scale meter for a brine, solvent or gas duty. Before we ship, we ask for medium, density or concentration, normal and maximum flow, line pressure, temperature and connection standard, then select the float material and scale strip accordingly. Gas duty needs one more step: the air scale is only valid at the calibration pressure, so for compressed air at 0.6 MPa the actual reading must be corrected for pressure and temperature.
If you are unsure, send the pump curve and the pipe size. We will reply with a marked-up selection sheet showing the float number, the scale range and the expected working position, which is faster than testing three different meters on site.
| Condition | A. Typical failure mode without the meter | B. Same line after the meter is installed |
|---|---|---|
| How flow is confirmed | Pump stroke setting is trusted; flow only proven by a tank draw-down test once per shift. | Float position visible continuously; a falling float during a stroke cycle shows air ingress immediately. |
| Effect of a worn diaphragm | Delivery drops silently, operator compensates by increasing stroke and over-doses the line. | Lower float position is spotted at the next walk-round; pump is serviced before the batch is affected. |
| Chemical consumption | Typical over-dose of 10-25% to cover uncertainty, plus discharge compliance risk. | Dose trimmed to the set point; users report 10-20% lower chemical spend within the first quarter. |
| Downtime pattern | Reactive: batch failure or permit exceedance triggers investigation. | Preventive: float behaviour flags the fault while the line is still running. |
| Industry | Municipal drinking water treatment, 12,000 m3/day plant |
| Site / region | Binh Duong province, Vietnam |
| Medium | Sodium hypochlorite 10%, density 1.15 kg/L |
| Flow range | 8-25 L/h normal, 30 L/h maximum |
| Pressure and temperature | 0.35 MPa line pressure, 28-34 C ambient, no direct sun |
| Connection | 1/2 inch BSP female, PVC pipework |
| Configuration supplied | QWYB-LZD511, PVC end fittings, 316L float, hypochlorite scale strip, wall bracket |
| Previous problem | Diaphragm pump stroke was adjusted by trial; two permit exceedances in one year traced to air ingress at the suction foot valve |
| What changed | Meter installed after the pump discharge, float position checked at every shift handover and logged with the dose record |
| Measured result | Hypochlorite consumption down 18% over four months, zero permit exceedances, foot valve replaced before failure twice |
| Industry | Chemical pilot plant and process development laboratory |
| Site / region | Wroclaw, Poland |
| Medium | Cooling water with corrosion inhibitor, occasionally turbid |
| Flow range | 20-60 L/h per branch, four branches |
| Pressure and temperature | 0.3 MPa, 12-38 C |
| Connection | 1/2 inch NPT female, SS304 fittings |
| Configuration supplied | QWYB-LZD511, SS304 fittings, 316L float, dual scale, panel mounted in a 4-branch manifold |
| Previous problem | Branches were balanced by valve feel; reactor jackets ran unevenly and one branch boiled off during exothermic runs |
| What changed | One meter per branch on a common panel, all four balanced to 45 L/h at commissioning, readings photographed into the batch record |
| Measured result | Jacket temperature spread reduced from 9 C to 2 C between reactors, batch reproducibility complaints stopped |
- Readable without power - works in unpowered skids, hazardous areas and during commissioning before the control system is live.
- Real flow, not a calculation - no density, k-factor or pipe roughness input required to get a number.
- Fast fault isolation - separates pump, valve and blockage problems in seconds instead of hours.
- Low cost of ownership - tube and float are consumable spares priced at a fraction of a transmitter.
- Forgiving installation - two threaded connections, no straight-run electronics, no grounding.
- Documented delivery - each meter ships with a tested scale strip, float number and pressure test record.
| Model | QWYB-LZD511 (LZB-15 body) |
| Water flow range | 6-60 L/h |
| Air flow range | 0.1-1 m3/h at 20 C and 101.3 kPa |
| Accuracy class | 2.5 (VDI/VDE 3513 based scale) |
| Measuring tube | Borosilicate glass 3.3 |
| Float | 316L stainless steel; PTFE or PVC option |
| End fittings | PVC, brass or SS304 |
| Process connection | 1/2 inch female thread, NPT or BSP |
| Pressure and temperature limits | PVC 0.6 MPa / 0-60 C; stainless steel 1.0 MPa / 0-120 C |
| Pressure loss | 2-3 kPa at full scale on water |
| Installation | Vertical, flow bottom to top, 5D upstream and 3D downstream straight pipe |
For mildly turbid water it works, but the tube will need cleaning more often because deposits change the annular gap and push the float high. Where solids or opacity are permanent, a glass tube is the wrong choice: use a clamp-on ultrasonic meter or an electromagnetic meter instead, both of which read through the pipe wall or a lined bore without a sight glass. If you must keep a visual reference on a dirty line, install the rotameter on a clean bypass loop with a small filter ahead of it, and clean the tube on a fixed quarterly interval. Send us a sample description and we will tell you honestly whether a rotameter will survive the duty.
The engraved air scale is valid for air at 20 C and atmospheric pressure. For another gas at the same conditions, multiply the reading by the square root of the ratio of the two densities, measured against air. For a line under pressure, apply a second correction using the absolute working pressure versus atmospheric pressure on the gas side of the float. In practice: corrected flow equals indicated flow times the square root of density ratio, then multiplied by the square root of absolute pressure ratio. Because gases are compressible, any reading above about 0.5 MPa should be confirmed with us before you rely on it for billing or custody work.
Usually not, but it must be checked against the available head. A tank with 600 mm of liquid above the outlet gives roughly 6 kPa of static head, so a full-scale pressure loss of 2-3 kPa consumes a third to a half of the driving force, and the resulting flow will sit lower on the scale than the same valve setting without a meter. Two easy fixes: choose the largest tube size that still keeps the working point above 30% of scale, or fit the meter on the discharge side of a small transfer pump. We size gravity lines against the actual head figure, so include the tank height in your enquiry.
Yes for this body style: the float must fall back to zero when flow stops, so the tube is installed vertically with upward flow. Allow at least five pipe diameters of straight run upstream and three downstream, measured from the nearest valve, elbow or pump outlet, to keep the float from spinning against a swirling stream. A needle valve downstream is preferred for fine control because throttling upstream can release dissolved gas and make the float chatter. For tight skids, a 90 degree elbow directly below the inlet is acceptable if a stilling vane is fitted, which we can supply as an option.
If the duty needs a signal to the PLC, a higher pressure rating or a hygienic finish, these pages cover the alternatives in the same family:
- Metal tube float flowmeter with 4-20 mA and HART output - for pressurised gas and liquid lines that must report to a control system.
- Micro metal tube float flowmeter for very low flows - when the working point sits below 6 L/h.
- Sanitary stainless steel float flowmeter - tri-clamp body for CIP and SIP duties.
- Compact wafer electromagnetic flowmeter - no moving parts for dirty or conductive media.
Send the medium, the normal and maximum flow, the line pressure and your connection standard, and we will return a selection sheet with the float number, scale range and expected float position within one working day.
Product Highlights
Glass tube rotameter LZB-15 with 6-60 L/h water range and dual water/air scale. Borosilicate tube, 316L float, PVC or SS304 fittings, class 2.5 accuracy, no power needed. Inquire with your medium and range for a same-day selection sheet.
Petroleum Radar Level Gauge 26GHz High Temperature Industrial
Petroleum Radar Level Gauge brings 26GHz radar precision and high-temperature capability to oil storage tank measurement. Every millimeter of level is tracked accurately to prevent inventory loss and safety risk. Inquire now for specifications.
Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor
Portable FMCW Radar Level Gauge brings laboratory-grade radar measurement to any tank in the plant or field. With IP67 protection and quick setup, it delivers accurate liquid level readings without permanent installation. Contact us for specifications.
Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay
Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.
Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement
Universal Gauge Pressure Transmitter measures pressure relative to the atmosphere for pump discharge, line pressure, tank head and filter differential applications. With 4-20mA output, it suits oil, water and gas measurement. Contact us for range options.
Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.