Steam Jacket Metal Tube Float Flowmeter 400 C Heat Transfer Oil Bitumen Rotameter
Product Details
| Model: | QWYB-LZD513 | Max Medium Temperature: | 400 C With Jacket In Service |
|---|---|---|---|
| Jacket Medium: | Saturated Steam Up To 0.5 MPa, Or Thermal Oil Up To 0.35 MPa | Liquid Flow Range: | 2.5-25000 L/h Depending On DN |
| Gas Flow Range: | 0.15-800 M3/h Depending On DN | Accuracy: | 1.5 Liquid / 2.5 Gas |
| Wetted Material: | 316L Stainless Steel, Graphite Packing | Working Pressure: | 2.5 / 4.0 / 6.4 MPa |
| Nominal Diameter: | DN15-DN80, Flanged DIN Or ANSI | Output Signal: | 4-20 MA, HART Optional |
| Jacket Connection: | 1/2 Inch Threaded Inlet And Outlet | Thermal Protection: | Removable Stainless Clad Insulation Blanket |
| Highlight |
Steam Jacket High Temperature Flowmeter,Heat Transfer Oil Rotameter 400 C,Graphite Packed 316L Measuring Tube |
||
Product Description
media to 400 C | steam or oil jacket | 316L wetted parts | to 6.4 MPa
Bitumen, molten sulphur, resin, chocolate and heat transfer oil all behave in the same inconvenient way: they flow perfectly at temperature and set solid inside a measuring tube that runs a few degrees cooler. This page explains why jacketing is a mechanical requirement rather than an accessory, how the heat path is designed, and how to size the float for the viscosity you actually have at 300 C rather than the water data on a catalogue page.
An unjacketed meter mounted in a hot line loses heat through its own body, through the pipe flanges and through the surrounding air. The tube wall runs perhaps 40-80 C below the bulk temperature on an uninsulated installation, which is enough to drop bitumen or sulphur below its solidification point at the wall. The float then sits in a ring of solidified product, stops responding, and the reading freezes at whatever value it last held - which is the most dangerous failure mode on a loading line, because the instrument still shows a number.
The usual workaround is a weekly steam-out and manual clean, which converts a measurement point into a maintenance task and shortens tube life through repeated thermal shock. A jacket changes the physics: the measuring chamber stays above the solidification temperature for as long as heat is supplied, so the medium behaves inside the meter exactly as it does inside the pipe.
A welded jacket surrounds the tapered measuring tube over its full length, with 1/2 inch inlet and outlet connections at the bottom and top so that condensate drains and vapour does not air-lock the pocket. Saturated steam at 0.5 MPa holds roughly 159 C at the jacket wall; thermal oil allows jacket temperatures above 300 C, which is what makes the 400 C media rating achievable in practice.
Two installation details matter more than the jacket design itself. The jacket must be put into service before the process line is opened, so the tube is already hot when product arrives, and the steam trap must be sized for the condensate load rather than copied from a tracing line. Where the meter sits between two flanges without insulation, a removable stainless clad blanket over the body is included as standard, because an uninsulated jacketed body still loses more heat than the jacket can supply.
- Jacket connections are threaded 1/2 inch, arranged inlet low and outlet high, so the pocket fills completely.
- The scale frame is mounted away from the jacket wall so the pointer stays readable with the blanket fitted.
- Preheat time from cold is typically 30-40 minutes for a DN50 body at 0.5 MPa steam, which belongs in the start-up procedure.
At 400 C, the failure points move. Elastomer seals are out, so the body uses graphite packing with a PTFE backup ring only where the temperature allows it. Standard neodymium magnets lose strength above roughly 150 C, so the coupling magnet on the high temperature version is a samarium-cobalt type mounted in a heat-isolated housing. The 316L tube wall is thicker than the ambient version to resist both pressure and the thermal gradient across the jacket.
- Graphite packing - maintains sealing at 400 C without the creep that kills PTFE at half that temperature.
- Heat isolated magnet coupling - keeps the indicating side cool so the pointer linkage does not seize.
- Heavy wall 316L tube - 6.4 MPa class available without changing the DN range.
- Flanged ends only - DIN or ANSI, because a threaded joint on a hot bitumen line is a leak waiting to happen.
- Hydro tested at 1.5 times rating - jacket circuit pressure tested separately before assembly.
- Removable insulation - service the pointer or the packing without destroying the thermal cover.
The single most common error on hot service meters is ordering by the water flow range in a catalogue. A float sized for water at 20 C will read high in a viscous oil at 250 C, because the drag force on the float changes with viscosity and the correction is not linear. We ask for the medium, the operating temperature, the viscosity at that temperature, the density at that temperature, and the normal plus maximum flow, then select the float and scale strip for that condition.
Where viscosity is unknown, a laboratory viscosity at two temperatures is enough to interpolate. If the product is a blend or its properties vary by batch, tell us the worst case rather than the average; a meter sized for the best case will sit off scale on the cold end of the batch. We mark the selected float number on the calibration sheet so a replacement can be ordered without repeating the calculation.
| Condition | A. Typical failure mode without the meter | B. Same line after the meter is installed |
|---|---|---|
| Reading stability on a hot line | Float sticks as product solidifies at the tube wall; the pointer holds a false value for weeks. | Tube wall stays above solidification temperature, so the float responds to every flow change. |
| Maintenance pattern | Weekly steam-out and manual cleaning, tube replaced every 6-12 months from thermal shock. | Jacket kept in service, cleaning interval measured in quarters, tube life no longer maintenance driven. |
| Loading accuracy | Batch quantities drift because the reading is stale; arguments at the weighbridge. | Reading tracks the loading rate; batch total confirmed per truck without a second reference. |
| Start-up discipline | Cold meter hit with hot product, cracking risk and false readings. | Preheat step written into the procedure, meter at temperature before the valve opens. |
| Industry | Road construction materials, bitumen terminal |
| Site / region | Tashkent region, Uzbekistan |
| Medium | Penetration grade bitumen 60/70, loading at 155-170 C |
| Flow range | 4-9 m3/h, maximum 12 m3/h |
| Pressure and temperature | 1.0 MPa line, 0.4 MPa steam available at 152 C |
| Connection | DN50 flanged, ANSI 150, 1/2 inch jacket connections |
| Configuration supplied | QWYB-LZD513, 316L body, 2.5 MPa class, steam jacket, local pointer plus 4-20 mA to the loading controller |
| Previous problem | Unjacketed meter seized after two weeks; loading quantities were estimated from tank dips and disputed by hauliers |
| What changed | Jacketed meter installed downstream of the loading pump, preheat procedure added, steam trap replaced with a thermostatic type |
| Measured result | Reading stable through a full loading season, tank dip reconciliation disputes stopped, one clean-out in 14 months |
| Industry | Chemical processing, reactor heating |
| Site / region | Izmir, Turkey |
| Medium | Synthetic heat transfer oil, 285-300 C |
| Flow range | 8-20 m3/h per reactor loop, low alarm at 9 m3/h |
| Pressure and temperature | 1.6 MPa, jacket fed with thermal oil from the same header at 0.3 MPa |
| Connection | DN80 flanged, DIN PN16 |
| Configuration supplied | QWYB-LZD513, 316L body, 4.0 MPa class, oil jacket, HART output to DCS, stainless insulation blanket |
| Previous problem | Orifice plate lost accuracy at low flow and could not show flow below 15% of range; pump cavitation at low loop flow went undetected |
| What changed | Meter replaced the orifice on each loop, jacket taken from the heater outlet header, low flow value trended in DCS |
| Measured result | Low flow events detected and corrected before cavitation damage, reactor temperature stability improved, no orifice plate replacement costs |
- Eliminates the cleaning task - no weekly steam-out, no tube replacement cycle driven by thermal shock.
- Stops stale readings - a float that responds is the difference between measuring and guessing on a loading line.
- Handles 6.4 MPa at 400 C - heavy wall 316L construction covers high pressure hot water and thermal fluid.
- Jacket and process tested separately - leak between circuits is excluded before the meter leaves the works.
- Documented for audit - material certificate, hydro test report, calibration sheet and jacket pressure test on file.
- Field serviceable - packing and pointer linkage accessible without removing the body from the line.
| Model | QWYB-LZD513 |
| Maximum medium temperature | 400 C with the jacket in service |
| Jacket medium | Saturated steam up to 0.5 MPa, or thermal oil up to 0.35 MPa |
| Flow range | Liquid 2.5-25000 L/h; gas 0.15-800 m3/h depending on DN |
| Accuracy | 1.5 liquid / 2.5 gas |
| Wetted material and sealing | 316L stainless steel tube, graphite packing |
| Pressure class | 2.5 / 4.0 / 6.4 MPa |
| Size and connection | DN15-DN80, flanged DIN or ANSI, 1/2 inch jacket ports |
| Output | 4-20 mA two wire, HART optional |
| Insulation | Removable stainless clad blanket, standard |
| Testing | Hydro test at 1.5 times rating, separate jacket pressure test, flow calibration record |
Two alternatives are used in practice. Thermal oil from an existing heater header is the better option when the product must stay above 200 C, because the jacket then reaches 300 C or more at low pressure; this is the configuration we supply for most heat transfer oil loops. Where the plant has neither steam nor oil, an electrically traced jacket with a thermostatic controller can be built, but the heat input is concentrated and the temperature uniformity across the tube is poorer, so we would normally recommend electric tracing on the adjacent pipework combined with a jacketed meter fed from a small local oil circuit. Send us the available utilities and target wall temperature and we will propose the cheapest workable arrangement.
It changes what you should check rather than how often. The flow scale itself does not drift, because the tube and scale are fixed geometry, but two things deserve attention on hot service: the float can become coated with carbonised product, which pushes the reading high, and the magnet coupling can weaken if the indicating side overheats. Our recommendation for continuous service near 400 C is an annual inspection where the tube is inspected for coating, the packing is checked for leakage, and the pointer is confirmed to return to zero when flow stops. Plants that clean the tube at that interval typically run five years or more without replacing parts.
Because the float reaches equilibrium where drag balances its weight, and drag depends on both density and viscosity. On a light oil at 300 C, viscosity may be a few centistokes and the flow curve is close to the water curve. On the same line at 120 C, viscosity can be twenty times higher and the float sits noticeably lower for the same volumetric flow, so a meter scaled on water data would read low by a wide margin. Supplying viscosity at the real operating temperature lets us choose the correct float shape and scale strip, which is the difference between a useful instrument and one the operators learn to ignore.
Each unit is delivered with a material certificate to EN 10204 3.1 for the wetted parts, a hydrostatic test report at 1.5 times the rated pressure, a separate pressure test record for the jacket circuit, a flow calibration sheet showing the float number and the verified points, a dimensional drawing for line integration, and an installation and preheat procedure. Where the project requires PED or a notified body certificate, that is quoted as an option and the lead time extends by roughly two weeks. Third party inspection, typically SGS or TUV witness at the hydro test, can also be arranged if your client specifies it.
These pages cover the adjacent hot and viscous duties:
- Steam jacketed oval gear flowmeter for bitumen and asphalt batching - positive displacement alternative for high viscosity batch metering.
- Steam traceable orifice plate flowmeter with temperature and pressure compensation - for larger steam and hot water lines.
- High pressure metal tube float flowmeter - ambient temperature duties up to and beyond 4.0 MPa.
- Sanitary stainless steel float flowmeter - hygienic alternative where the product is food grade rather than hot.
Send the medium, operating temperature, viscosity at that temperature, flow range, pressure and flange standard, and we will return the float selection, jacket arrangement and a quotation within two working days.
Product Highlights
Metal tube float flowmeter with steam or thermal oil jacket for media up to 400 C. 316L wetted parts, graphite packing, pressure classes to 6.4 MPa, 4-20 mA or HART output. Inquire with viscosity at temperature for correct sizing.
Petroleum Radar Level Gauge 26GHz High Temperature Industrial
Petroleum Radar Level Gauge brings 26GHz radar precision and high-temperature capability to oil storage tank measurement. Every millimeter of level is tracked accurately to prevent inventory loss and safety risk. Inquire now for specifications.
Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor
Portable FMCW Radar Level Gauge brings laboratory-grade radar measurement to any tank in the plant or field. With IP67 protection and quick setup, it delivers accurate liquid level readings without permanent installation. Contact us for specifications.
Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay
Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.
Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement
Universal Gauge Pressure Transmitter measures pressure relative to the atmosphere for pump discharge, line pressure, tank head and filter differential applications. With 4-20mA output, it suits oil, water and gas measurement. Contact us for range options.
Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.