| Place of Origin: | China |
| Brand Name: | QINWEIYB |
| Model Number: | YSE-60II |
| Minimum Order Quantity: | 1Set |
|---|---|
| Price: | Negotiable |
| Packaging Details: | Carton |
| Delivery Time: | 5-8 work days |
| Payment Terms: | Western Union,T/T,D/P,D/A,L/C |
| Supply Ability: | 100PCS/Month |
| Electricalconnection: | M12 Connector | Measurement Range: | 0 To 1000 Psi |
|---|---|---|---|
| Switch Type: | Pressure Switch | Electrical Connections: | DIN43650 Hersman Junction Box |
| Warranty: | 12 Months | Material: | Stainless Steel 316L |
| Zeroadjustment: | External Zero Adjustment | Wetted Parts: | Stainless Steel 304 |
| Output: | 4 ~ 20mADC | Pressure Type: | Gauge/Absolute/Sealed Gauge |
| Highlight: | SF6 Gas Density Relay,SF6 Gas Density Monitor |
||
SF6 Gas Density Relay With Pressure 0.4 To 0.6 MPa And Temperature Range -20°C To +60°C
The SF6 gas density relay, also known as the SF6 gas density controller or monitor, is a crucial monitoring device for high-voltage switchgear in the energy industry. It is mainly applied in SF6 insulated equipment such as GIS combined electrical apparatus, circuit breakers, and transformers. By integrating pressure measurement and limit switch functions, this device continuously monitors the SF6 gas density within sealed containers. When the density falls below or exceeds the set threshold, it triggers alarm, lockout, or overpressure signals to ensure the safe operation of electrical equipment.
The density of SF6 gas directly affects the insulation and arc-extinguishing capabilities of equipment. The density relay monitors the gas density in real time (actually the pressure compensated for temperature) to determine if there is a leak or abnormality. When the density drops below the alarm value, it sends a signal; when it drops below the lockout value, it locks out the equipment operation to prevent accidents.
The pressure of SF6 gas changes with temperature, but the density relay compensates for the temperature effect through a double-layer metal strip or a standard gas chamber, ensuring that the reading always corresponds to the standard value at 20℃ and avoiding misjudgment.
When the gas density drops to a dangerous level, the relay triggers an alarm or lockout signal, which links to the control system to cut off the power or prohibit opening and closing operations, ensuring the safety of the equipment.
According to structure and function, SF6 density relays can be classified into the following types: