Quality Flush Diaphragm Level Transmitter Sanitary Tri Clamp Hygienic Food Pharmaceutical Tank Level Sensor 4-20mA factory
<
Quality Flush Diaphragm Level Transmitter Sanitary Tri Clamp Hygienic Food Pharmaceutical Tank Level Sensor 4-20mA factory
Quality Flush Diaphragm Level Transmitter Sanitary Tri Clamp Hygienic Food Pharmaceutical Tank Level Sensor 4-20mA factory
Quality Flush Diaphragm Level Transmitter Sanitary Tri Clamp Hygienic Food Pharmaceutical Tank Level Sensor 4-20mA factory
Quality Flush Diaphragm Level Transmitter Sanitary Tri Clamp Hygienic Food Pharmaceutical Tank Level Sensor 4-20mA factory
>

Flush Diaphragm Level Transmitter Sanitary Tri Clamp Hygienic Food Pharmaceutical Tank Level Sensor 4-20mA

Brand Name: QINWEIYB
Model Number: QWY-FDL601
Place of Origin: Guangdong, China
Certification: ISO 9001:2015
Minimum Order Quantity: 1 Piece
Price: USD 100-280 / Piece
Supply Ability: 500 Pieces per Month

Product Details


Connection: Tri-clamp 1.5-4 Inch Diaphragm: Flush, Sanitary Design
Output Signal: 4-20 MA Measuring Range: 0-10 M
Cleaning: CIP / SIP Capable Wetted Materials: Food-grade Stainless Steel
Highlight

Sanitary Tri Clamp Connection

,

Hygienic Food Level Measurement

,

CIP SIP Flush Diaphragm Transmitter

Product Description

Sanitary Flush Diaphragm Level Transmitter with Tri-Clamp Connection for Food and Pharmaceutical Tanks

Hygienic processes demand instruments that are as cleanable as the tanks they measure. This sanitary flush diaphragm level transmitter features a tri-clamp connection, a smooth crevice-free wetted surface and 4-20mA output, delivering accurate level measurement for food, beverage, dairy and pharmaceutical tanks where cleanliness is non-negotiable.

Why Do You Need a Sanitary Level Transmitter?

Food, beverage, dairy and pharmaceutical production is governed by strict hygiene standards: every surface that contacts the product must be smooth, non-toxic and cleanable, and any crevice can harbor bacteria and compromise product safety. Conventional level sensors with threads, cavities and complex shapes cannot be cleaned effectively and are not acceptable in hygienic processes. A sanitary level transmitter answers this with a flush diaphragm mounted in a tri-clamp connection: the wetted surface is smooth and crevice-free, the tri-clamp fitting allows quick installation and removal for cleaning, and the design withstands the CIP (clean-in-place) and SIP (sterilize-in-place) procedures used in hygienic plants. The flush diaphragm also prevents product buildup, which is essential with viscous food products such as milk, cream, syrup and pastes. For plants that must measure level without compromising hygiene, the sanitary flush diaphragm transmitter is the correct choice.

Working Principle: Flush Diaphragm Hydrostatic Measurement in Hygienic Design

The transmitter measures the hydrostatic pressure of the liquid column in the tank through a flush diaphragm mounted flush with the tri-clamp fitting. The diaphragm is in direct contact with the product; the pressure increases with the liquid level above it, and the sensing element converts this pressure into an electronic signal. The electronics calculate the level by subtracting the mounting height and compensating for the product density. The hygienic design ensures the wetted parts are smooth, crevice-free and made of approved materials, allowing complete cleaning and sterilization. The tri-clamp connection provides a hygienic, leak-free seal that can be quickly disconnected for inspection or cleaning. The level value is delivered as a 4-20mA output, connecting directly to process control and recording systems.

Structural Advantages of the Sanitary Transmitter

  • Tri-clamp connection: hygienic, quick-disconnect mounting.
  • Flush diaphragm: smooth, crevice-free wetted surface.
  • CIP/SIP capable: withstands cleaning and sterilization.
  • Approved materials: food-grade wetted parts.
  • Anti-buildup design: no cavities for product to lodge in.
  • 4-20mA output: standard integration with process control.
  • No moving parts: low maintenance, long service life.
  • Compact hygienic housing: suits food and pharma plants.

Selection and Installation Guide

Select the tri-clamp size to match your tank fitting, typically 1.5 to 4 inches, and confirm the wetted materials meet your product and cleaning requirements. The transmitter should be mounted at a height where the diaphragm is covered by product at the minimum level to be measured, and the level calculation accounts for the distance to the tank bottom. The tri-clamp connection is installed with a hygienic gasket and clamp, torqued according to specification to ensure a leak-free, crevice-free joint. The 4-20mA wiring connects to your control system, and the transmitter is configured for the tank height and product density during commissioning. The unit is designed for routine CIP/SIP cycles without removal, and can be quickly dismounted for manual inspection when required.

Pain Point Analysis: 4 Challenging Working Conditions

Working ConditionTypical FailureWhy Conventional Sensors FailSanitary Solution
Hygienic standards complianceRejected by auditsCrevices harbor bacteriaSmooth crevice-free wetted surface
Viscous food productsProduct buildup, false readingsMaterial lodges in cavitiesFlush diaphragm, nothing to accumulate on
CIP/SIP cleaning cyclesSensor damage, contaminationCannot withstand cleaningCIP/SIP capable hygienic design
Frequent product changeoverSlow cleaning, downtimeDifficult to removeTri-clamp quick disconnect

Application Cases

Case 1 - Dairy Storage Tank

Industry: Dairy processing

Application: Level monitoring of milk storage tanks

Measured Medium: Milk and cream

Range: 0-5 m

Process Temperature: 4-60 °C

Output Signal: 4-20 mA to process control

Key Challenge: Hygiene compliance and viscous product

Configuration: Sanitary flush diaphragm, 2-inch tri-clamp

Installation: Side mounted on tank, tri-clamp

Performance Result: Accurate level with full CIP compatibility

Case 2 - Pharmaceutical Process Vessel

Industry: Pharmaceutical manufacturing

Application: Level control in hygienic process vessels

Measured Medium: Pharmaceutical liquid

Range: 0-3 m

Process Temperature: 10-90 °C

Output Signal: 4-20 mA to batch control

Key Challenge: Sterile operation and product purity

Configuration: Sanitary transmitter, polished wetted parts

Installation: Tri-clamp mounted on vessel

Performance Result: Sterile-compatible level measurement

Product Advantages

  • Tri-clamp hygienic connection
  • Flush diaphragm, crevice-free surface
  • CIP and SIP cleaning compatible
  • Food-grade approved materials
  • Anti-buildup for viscous products
  • 4-20mA standard output
  • Quick disconnect for changeover
  • No moving parts, low maintenance

Technical Parameters

ParameterSpecification
ConnectionTri-clamp (1.5-4 inch)
DiaphragmFlush, sanitary design
Output Signal4-20 mA
Measuring Range0-10 m (configurable)
CleaningCIP / SIP capable
Wetted MaterialsFood-grade stainless steel
Supply Voltage12-36 VDC (typical 24 VDC)
Process Temperature-20 to +100 °C (media)
Surface FinishRa ≤ 0.8 µm wetted parts
Electrical ConnectionTerminal block, hygienic cable gland

SEO FAQ

Q1: What makes a level transmitter sanitary?

A sanitary level transmitter is designed to meet the hygiene standards of food, beverage, dairy and pharmaceutical production. Its wetted surfaces are smooth, crevice-free and made of food-grade approved materials, leaving no gaps or recesses where product or bacteria can accumulate. It uses hygienic connections such as tri-clamp fittings rather than threaded or flanged joints that could trap product, and it withstands the CIP (clean-in-place) and SIP (sterilize-in-place) procedures used to clean and sterilize process equipment. The flush diaphragm keeps the sensing surface level with the tank wall, preventing product buildup. These design features allow the transmitter to be cleaned and sterilized along with the tank, maintaining the hygiene integrity of the entire process.

Q2: Why use a tri-clamp connection?

The tri-clamp connection is the standard hygienic fitting in food and pharmaceutical processing because it combines a smooth, crevice-free seal with quick, tool-free disassembly. The fitting consists of two ferrule ends, a gasket and a clamp: when assembled, the gasket forms a flush, gap-free seal between the instrument and the tank nozzle, leaving no crevice for product or bacteria. When disassembled, the instrument can be removed in seconds for inspection, manual cleaning or replacement, which is valuable during product changeover and maintenance. The tri-clamp also provides a reliable, leak-free joint that withstands CIP/SIP cycles. This makes it the preferred connection for sanitary level instruments.

Q3: How does the transmitter handle CIP and SIP cleaning?

The transmitter is designed to withstand the cleaning and sterilization cycles used in hygienic plants. CIP (clean-in-place) circulates cleaning solutions, typically caustic and acid washes followed by rinse water, through the process equipment without disassembly; the transmitter's materials and seals resist these chemicals and the associated temperatures. SIP (sterilize-in-place) uses steam or hot water at elevated temperatures to sterilize the equipment; the transmitter tolerates these sterilization temperatures. Because the wetted surface is smooth and crevice-free, cleaning agents reach every surface and no product residue survives to contaminate the next batch. The transmitter remains installed during these cycles, maintaining measurement continuity and reducing downtime.

Q4: Can it measure viscous products without buildup?

Yes. The flush diaphragm presents a smooth surface level with the tank wall, so viscous products such as milk, cream, syrup, honey and pastes have no cavity or protrusion to accumulate on. Any product that touches the diaphragm is washed away by the liquid flow or the cleaning cycle, so the sensing surface remains clean and the reading stays accurate. This is a significant advantage over sensors with recessed diaphragms or protruding probes, which become coated with viscous products and drift out of calibration. The flush design also prevents dried product residue from forming between batches, supporting consistent measurement and easier cleaning.

Q5: What output and integration options are available?

The transmitter provides a standard 4-20mA analog output that connects directly to PLCs, DCS systems, batch controllers and recorders used in food and pharmaceutical plants. This allows the level value to be displayed, controlled, alarmed and recorded in the process control system. Depending on the configuration, digital communication options can be added for remote configuration and diagnostics. The 4-20mA signal can be scaled to display level in the units of your process, and the transmitter is configured for your tank geometry and product density during commissioning. Integration is straightforward, with standard two-wire wiring and no special interface hardware required.

Q6: What support and customization do you offer?

As the manufacturer, we provide direct technical support including tri-clamp sizing, material selection, density configuration and installation guidance. Customization options include tri-clamp size, measuring range, output signal, surface finish, gasket materials, labeling and packaging, plus OEM and ODM programs for hygienic process equipment manufacturers. Every transmitter is factory-calibrated and tested before shipment, and our engineers can review your tank, product and cleaning procedures to confirm the correct sanitary configuration. Contact us with your application details for a tailored recommendation and quotation.

Why Choose Our Sanitary Flush Diaphragm Level Transmitter?

Hygiene is not a feature, it is a requirement. This sanitary flush diaphragm transmitter meets it with a tri-clamp connection, a smooth crevice-free wetted surface and CIP/SIP compatibility, measuring viscous food and pharmaceutical products without buildup or contamination. The flush diaphragm keeps readings accurate batch after batch, and the quick-disconnect tri-clamp keeps changeover fast. As the manufacturer, you receive a factory-calibrated instrument, application-matched configuration and direct engineering support. When your product quality depends on clean measurement, choose the sanitary transmitter built for hygienic processes.

Product Highlights

Sanitary flush diaphragm level transmitter with tri-clamp connection for food, dairy and pharmaceutical tanks, CIP/SIP capable, 4-20mA output.

Related Products
Quality Petroleum Radar Level Gauge 26GHz High Temperature Industrial factory

Petroleum Radar Level Gauge 26GHz High Temperature Industrial

Petroleum Radar Level Gauge for High-Temperature Industrial Tank Measurement Oil storage is a high-stakes business: every millimeter of level represents valuable product, and every measurement error becomes an inventory loss or a safety risk. The QWRD80G603 petroleum radar level gauge brings 26GHz ...

Quality Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor factory

Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor

Portable FMCW Radar Level Gauge for Quick, Accurate Liquid Measurement Anywhere Sometimes you do not need a permanently installed instrument; you need a reliable level reading here, now, at any tank in the plant or in the field. The QWRD80G611 portable FMCW radar level gauge brings laboratory-grade ...

Quality Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay factory

Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay

Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.

Quality Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement factory

Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement

Universal Gauge Pressure Transmitter for Oil, Water and Gas 1. Why You Need a Gauge Pressure Transmitter Most industrial pressure measurements — pump discharge, line pressure, tank head, filter differential — are expressed relative to the surrounding atmosphere. A gauge pressure transmitter reads ...

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.