Product Details


Nominal Size: DN25 To DN100 (1 In To 4 In) Process Connection: Tri Clamp Per DIN 32676 / ISO 2852
Wetted Material: 316L (1.4404) With 3.1 Certificates Surface Finish: Ra 0.8 Micrometre Product Contact, Ra 1.6 Micrometre External
Gasket: EPDM Per 21 CFR 177.2600 Or PTFE Encapsulated Working Pressure: 10 Bar (145 Psi)
Working Temperature: 130 C Continuous, 140 C Short Term SIP Hygienic Standards: 3-A 63-03, EHEDG, FDA, EC 1935/2004
Accuracy: +/-1.5% Of Reading, Repeatability +/-0.1% Output And Power: 4-20 MA + HART, 24 V DC, Optional Totaliser
Highlight

Sanitary Tri Clamp Flowmeter

,

Hygienic Orifice Plate Flow Meter

,

316L CIP Cleanable Orifice Plate

Product Description

Sanitary Tri Clamp Orifice Plate Flowmeter for Food, Dairy and Pharma Lines

On a hygienic line the flow element has to do two jobs: measure the product during production and survive being cleaned afterwards without becoming a harbour for bacteria. This sanitary assembly uses a 316L plate held between tri clamp ferrules, flush mounted with an FDA compliant gasket, a product contact finish of Ra 0.8 micrometre, and a clamp-type differential pressure seal, so there is no threaded pocket, no dead leg and nothing for a CIP cycle to miss.

Why a Standard Industrial Orifice Plate Cannot Go on a Hygienic Line

The failure is almost never accuracy. A general purpose carrier ring introduces a threaded tap hole, a gasket crevice and a step at the flange face; all three trap product, and none of them can be cleaned in place reliably. During the next CIP cycle the caustic flows past the pocket rather than through it, the residue stays, and the problem surfaces later as a microbiological result or a failed audit rather than as a flow error. That is why hygienic plants treat the connection and the surface finish as part of the measurement specification.

Operating pointRaw milk reception line, 4 C productPurified water loop, 80 C, pharma
Hygiene requirementNo crevice, no dead leg, fully drainable, allergen changeover documentedRouge-free, validated SIP, documented surface finish for the validation file
Cleaning regimeCIP at 85 C, 20 minutes, 1.5% caustic then acid, rinse to conductivitySIP at 121 C or ozonated water, plus periodic passivation
Risk from a standard plateProduct trapped behind the gasket and in the threaded tap; bacterial growth between production runsFinish not documented, crevice corrosion at the tap, validation evidence missing
Required surfaceRa 0.8 micrometre or better on product contact, no pits, welds ground flushRa 0.8 micrometre or better, material certificates 3.1, no dead volume
Required connectionTri clamp per DIN 32676, EPDM gasket, hygienic DP sealTri clamp or aseptic flange, PTFE or EPDM gasket with USP Class VI support
Recommended configurationDN50 plate, Ra 0.8, EPDM gasket, clamp-type DP transmitterDN25 to DN40 plate, Ra 0.8, PTFE encapsulated gasket, clamp seal with 3.1 certificates

How the Sanitary Orifice Plate Measures Without Creating a Dead Pocket

The measuring principle is unchanged: fluid accelerates through the bore and the differential pressure across the plate follows the square of flow. What changes is how that pressure is captured. Instead of drilled corner taps, the DP is taken through a clamp-type diaphragm seal mounted directly on the ferrule, so there is no drilling into the product path and no wetted pocket behind the plate. The two halves of the ferrule close on the plate with a single gasket, and the plate is centred by the ferrule step rather than by the bolts, which keeps the bore concentric and the assembly self-draining in either orientation.

Surface finish does the rest of the work. Product contact faces are machined and electropolished to Ra 0.8 micrometre or better, edges are radiused, and the gasket sits in a machined groove so that it presents a flush face to the flow rather than an exposed lip. The result is a flow restriction that behaves like a section of polished pipe from the cleaner's point of view, while still generating a stable, repeatable differential pressure.

Because the plate is a simple flat disc, it can be removed, inspected and replaced without cutting the line, and a spare plate can be carried sterilised and swapped during a changeover window.

Two other options usually sit on the same shortlist. Where the product is conductive and the line can carry a full bore meter, a sanitary electromagnetic flowmeter removes the restriction altogether and adds no pressure loss, at a higher capital cost and a conductivity requirement the plate does not have. For small dosing branches a sanitary stainless steel float flowmeter gives local indication with no power at all. The plate keeps its place in the middle: accurate enough for reconciliation, cheap enough to fit on every line, and simple enough to clean and inspect without a specialist.

Structural Advantages for CIP and SIP Service

Flush product contact, no threaded tapDifferential pressure is taken through a clamp-type diaphragm seal on the ferrule, so nothing is drilled into the product path and there is no threaded pocket to trap residue.
Ra 0.8 micrometre electropolished finishProduct contact faces are machined then electropolished to Ra 0.8 micrometre or better, with radiused edges and a machined gasket groove that presents a flush face to the flow.
Self-draining in either orientationThe ferrule step centres the plate and the assembly drains under gravity mounted horizontally or vertically, which is what makes a documented drainability claim possible.
3-A and EHEDG aligned designGeometry and finish follow 3-A 63-03 and EHEDG hygienic design guidance, with FDA compliant elastomer and 21 CFR 177.2600 gasket documentation supplied for the validation file.
316L throughout, fully traceablePlate, ferrules and seal bodies in 316L with 3.1 material certificates, heat numbers matched to the plate stamp so an auditor can trace the wetted part.
CIP and SIP rated to 130 CContinuous service to 130 C and short steam sterilisation to 140 C, 10 bar working pressure, with the gasket grade selected for the actual cleaning chemistry rather than a generic default.

Selection Data, Field Cases and Questions Engineers Ask

Case 1 - Raw milk reception metering, dairy

ProjectRaw milk reception line metering and audit
IndustryDairy processing
LocationFriesland, Netherlands
Line and serviceDN50 tri clamp, 1 in, 4 C raw milk, 18,000 L/h
Fluid conditionRaw whole milk, gentle flow required, CIP at 85 C between deliveries
Problem on siteA general purpose orifice carrier had been proposed for cost reasons, but the QA auditor rejected it over a 3 mm gasket crevice and an undocumented internal finish
Configuration suppliedDN50 316L plate at Ra 0.8 micrometre, DIN 32676 tri clamp, EPDM gasket per 21 CFR 177.2600, clamp-type DP transmitter with hygienic diaphragm seal
CommissioningInstalled during a delivery gap, drainability checked in both orientations, CIP cycle verified at 85 C for 20 minutes with conductivity rinse end point
Measured resultPassed the customer's 3-A audit with no findings; changeover between product and CIP confirmed by conductivity, and reception totals reconciled with supplier weighbridge tickets to within 0.6%
Delivery6 weeks, with 3.1 certificates and finish measurement report

Case 2 - Brewery CIP supply circuit

ProjectCIP supply flow verification across four tanks
IndustryBrewing and beverage
LocationGuadalajara, Mexico
Line and serviceDN65 tri clamp, 1.6 bar, 80 C, 12 m3/h design
Fluid condition1.5% sodium hydroxide CIP solution, alternating with acid and rinse water
Problem on siteCleaning flow was inferred from pump curves; two tanks repeatedly failed rinse validation because actual CIP flow was about 22% below the assumed value
Configuration suppliedDN65 316L sanitary plate, tri clamp, PTFE gasket for the caustic duty, clamp DP transmitter with local totaliser in m3
CommissioningFlow verified against a calibrated tank fill at three valve positions, alarm set at 90% of target CIP flow
Measured resultActual CIP flow measured at 9.7 m3/h instead of the assumed 12; after correcting the pump setting, rinse cycles shortened by six minutes per tank and rinse water use fell about 4%
Delivery5 weeks, two spare plates supplied for changeover windows

Technical parameters

ParameterSpecification
Nominal sizeDN25 to DN100 (1 in to 4 in)
Process connectionTri clamp per DIN 32676 or ISO 2852, other hygienic ends on request
Wetted material316L (1.4404), 3.1 certificates with heat number traceability
Surface finishRa 0.8 micrometre or better on product contact, Ra 1.6 micrometre external
GasketEPDM per 21 CFR 177.2600 or PTFE encapsulated, selected for the cleaning chemistry
Working pressure10 bar (145 psi)
Working temperature130 C continuous, 140 C short term steam sterilisation
Hygienic standards3-A 63-03, EHEDG guidance, FDA compliant materials, EC 1935/2004
Accuracyplus or minus 1.5% of reading, repeatability plus or minus 0.1%
Output and power4-20 mA plus HART, 24 V DC, optional local totaliser

How This Sanitary Meter Compares With Other Hygienic Options

All three options below are cleanable. What separates them is pressure loss, turndown and the documentation each one can put in front of an auditor.

OptionProduct contact and finishTurndownConstraint to check first
This sanitary orifice plate316L, Ra 0.8 micrometre, tri clamp, no dead leg3:1Needs 3D to 5D of straight run, plus DP signal conditioning
Sanitary electromagnetic flowmeter316L liner and electrodes, tri clamp, full bore20:1 and betterLiquid must be conductive, typically above 5 microsiemens per centimetre
Sanitary float flowmeter316L tube and float, tri clamp10:1Vertical upward flow only, glass or tube must be visible for reading
Standard stainless orifice plate316L, industrial finish, threaded or flanged taps3:1Gasket crevice and tap pocket make it unsuitable for hygienic duty

Related pages: compact sanitary electromagnetic flowmeter DN15-DN100 · sanitary stainless steel float flowmeter · standard stainless steel orifice plate flowmeter · eccentric orifice plate flowmeter for dirty media · all orifice plate flowmeters · steam orifice plate flowmeter with temperature and pressure compensation · AGA-3 natural gas custody transfer meter run

Is this orifice plate 3-A and EHEDG compliant?

The assembly is designed to the 3-A 63-03 requirements for sensing and instrument fittings and follows EHEDG hygienic design guidance: flush product contact, no threaded connection in the product path, a radiused and electropolished finish at Ra 0.8 micrometre or better, and a gasket presented in a machined groove rather than as an exposed lip. Compliance is a property of the installed assembly, not the plate alone, so the certificates issued cover the plate, the ferrules and the specified gasket as a set. For an audit, ask for the material certificates, the finish measurement report, the gasket FDA reference and the drainability statement together, because that is the package an auditor will want to see.

Can the plate be cleaned in place, or must it be removed?

It is designed to be cleaned in place. The absence of a dead leg is the whole point of the clamp-type seal arrangement: CIP flow passes over a flush face and there is nowhere for product to sit. The practical conditions are that the line reaches the turbulence the CIP cycle assumes, the gasket grade suits the caustic and acid in use, and the assembly drains under gravity in the orientation it is fitted. Removing the plate is a changeover job, not a cleaning step, and takes a few minutes with a spare gasket. Many plants pull the plate once per campaign to inspect the bore edge, which also gives them a physical check on whether the finish is still intact.

Which gasket material should I specify for SIP at 130 C?

EPDM is the default for dairy and beverage because it handles caustic, acid and 85 C CIP well and stays compliant with 21 CFR 177.2600 at a sensible cost. Its weakness is repeated high temperature steam: continuous exposure above roughly 130 C hardens it and it loses compression set, so it needs replacing more often. For a loop that is steam sterilised regularly, specify a PTFE encapsulated gasket, which tolerates repeated SIP cycles and is easier to clean, at the cost of higher torque and a stiffer seal. Silicone is best avoided where fats or hydrocarbons are present. State the actual cleaning chemistry, temperature and cycle count at the enquiry stage; the gasket is the cheapest part of the assembly and the one most often responsible for a failed validation.

How do I document hygienic design for an FDA or notified-body audit?

Build the file around evidence rather than statements. Ask for 3.1 material certificates with heat numbers that match the stamp on the plate, a surface finish measurement report showing the Ra value at defined points on the product contact faces, the gasket declaration referencing 21 CFR 177.2600 or the relevant USP class, and a drainability statement describing the tested orientation. Add the 3-A and EHEDG documentation for the assembly and the elastomer. Where the plant runs an EHEDG or 3-A audit, the usual finding is not the instrument itself but a missing finish measurement report or a gasket grade that does not match the cleaning chemicals actually in use, so check those two against the CIP programme before the auditor does.

Product Highlights

Sanitary orifice plate flowmeter for food, dairy and pharma lines: 316L plate, Ra 0.8 micrometre product contact, DIN 32676 tri clamp, flush clamp-type DP seal and CIP / SIP service to 130 C. Request the hygienic documentation package and a quote.

RELATED PRODUCTS
Quality Petroleum Radar Level Gauge 26GHz High Temperature Industrial factory

Petroleum Radar Level Gauge 26GHz High Temperature Industrial

Petroleum Radar Level Gauge brings 26GHz radar precision and high-temperature capability to oil storage tank measurement. Every millimeter of level is tracked accurately to prevent inventory loss and safety risk. Inquire now for specifications.

Quality Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor factory

Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor

Portable FMCW Radar Level Gauge brings laboratory-grade radar measurement to any tank in the plant or field. With IP67 protection and quick setup, it delivers accurate liquid level readings without permanent installation. Contact us for specifications.

Quality Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay factory

Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay

Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.

Quality Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement factory

Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement

Universal Gauge Pressure Transmitter measures pressure relative to the atmosphere for pump discharge, line pressure, tank head and filter differential applications. With 4-20mA output, it suits oil, water and gas measurement. Contact us for range options.

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.