AGA-3 Natural Gas Orifice Meter Run Custody Transfer Flowmeter ANSI 300 600 Flanged

Brand Name: QINWEIYB
Model Number: QWLU-MR320
Place of Origin: Tianjin, China
Certification: ISO 9001:2015, CE, PED
Minimum Order Quantity: 1 Set
Price: USD 1,850-6,400 / Set
Supply Ability: 60 Sets per Month

Product Details


Line Size: DN50 To DN400 (2 In To 16 In) Pressure Rating: ANSI Class 300 / 600 / 900, RF Or RTJ
Design Pressure: Up To 10 MPa Standard, Higher On Request Governing Standards: AGA Report No.3, API MPMS 14.3, ISO 5167-2
Beta Ratio: 0.20 To 0.75 Orifice Plate: 316 SS, 3.175 Mm, 45 Degree Bevel, Bore Stamped With Heat Number
Meter Tube: A106 Gr.B Or 316L, Honed Or Pickled, ID Measured At Four Points Straight Lengths: 18D Upstream / 5D Downstream Typical
Instrumentation: DP + Static Pressure Transmitters, PT100, AGA-8 Flow Computer System Accuracy: +/-0.5% Of Reading, Repeatability +/-0.1%
Highlight

AGA-3 Orifice Meter Run

,

Natural Gas Custody Transfer Flowmeter

,

Orifice Fitting Meter Tube Assembly

Product Description

AGA-3 Natural Gas Orifice Meter Run for Custody Transfer

When two parties invoice each other against the same pipeline, a 1% disagreement is a commercial dispute, not a rounding error. This meter run is built as a single accountable assembly: honed meter tube, orifice fitting, concentric plate, DP and static pressure transmitters, RTD and a flow computer applying AGA Report No.3 with AGA-8 compressibility, delivered pressure tested and wet calibrated as one set.

Why Gas Custody Transfer Still Starts With an Orifice Meter Run

The orifice meter run survives because it is the only gas measuring device whose uncertainty is published, traceable and accepted by both sides of a contract. Turbine, ultrasonic and Coriolis meters are all better on turndown; none of them carries a century of published discharge coefficient data, nor can a plate be inspected, measured and replaced by the buyer's own technician in an afternoon. That is the commercial reason the meter run is still specified at city gates, compressor stations and plant fuel gas headers.

Operating point City gate pressure reduction station, 2.5 MPa to 0.4 MPa Compressor discharge, 8.0 MPa, wet gas carryover
Flow profile risk Regulators and headers sit close to the meter; swirl and asymmetry are the main bias source Pulsation from reciprocating machines distorts the DP signal at running frequency
Density and Z factor Large pressure drop across the station changes Z on each side of the plate High pressure and heavy components push Z well away from unity
Typical error source Uncorrected straight lengths and a plate bore that no longer matches its tag Liquid carryover eroding the plate edge and blocking tap holes
What custody transfer demands Traceable uncertainty, agreed correction method, both parties able to verify the plate Same, plus a plate that can be changed under pressure without venting the line
Recommended configuration 18D / 5D meter tube, senior fitting, flow computer with AGA-8 and live composition Honoured meter tube, dual chamber fitting, DP transmitter with manifold and blowdown, liquid trap upstream
How the Meter Run Converts Differential Pressure into Standard Cubic Metres

The measurement chain is short but every link is defined. Gas accelerates through the bore, and the corner-tap differential pressure is related to mass flow through the same square-law equation used for liquids, extended by two gas-specific terms: the expansibility factor epsilon accounting for compressibility across the plate, and the density term evaluated at upstream conditions. Volume at base conditions then follows from the AGA-8 compressibility factor and the gas composition.

What separates a meter run from a plate in a pipe is the geometry around it. The discharge coefficient in the equation is only valid while the velocity profile arriving at the plate matches the one used to derive it, which is why the upstream and downstream lengths, the internal bore tolerance and the tap hole squareness are all part of the instrument rather than installation details. Change any of them and the equation is no longer the equation you were invoiced against.

Because DP follows the square of flow, the run is sized for the contracted flow band. Below about 30% of the DP span the square root amplifies transmitter noise and the reading becomes unreliable, and above the span the plate edge and tap holes take a disproportionate beating.

The same plate geometry appears in three different levels of assembly on this site, and the difference is what the buyer is actually paying for: a standard stainless orifice plate in a flanged carrier gives indication duty on plant air and nitrogen, an ASME orifice gas flowmeter covers general gas service to ASME MFC-3M, and the meter run adds the documented geometry and correction method that a custody contract needs. Where the line is large and permanent pressure loss dominates the energy bill, a pitot tube flowmeter installs through a single tapping at a fraction of the cost.

Structural Details That Keep the Discharge Coefficient Valid
Honed meter tube with measured internal diameter304 or 316L tube is honed or pickled and the ID is measured at four points and two planes, with the average recorded on the certificate. That recorded diameter, not the nominal size, is what the flow computer uses.
Straight lengths built to the beta tableUpstream and downstream sections are fabricated to the length the selected beta ratio requires for the actual upstream fitting, then verified by dimensional report, so the coefficient stays valid instead of assumed.
Dual chamber orifice fitting as standardThe plate can be lifted into the upper chamber and replaced under line pressure with the line still live. No venting, no lost gas, no commercial argument about unaccounted volume during maintenance.
Concentric plate with stamped traceability3.175 mm 316 SS plate, 45 degree bevel, edge radius under 0.05 mm, bore measured and stamped on the tab together with the heat number, so anyone can verify the plate against the certificate with a calliper.
Orifice flange unions with plug-sealed tapsCorner taps are drilled square to the bore and fitted with screwed plugs so the tapping can be rodded out without dismantling the fitting, which matters on wet gas service.
Complete instrumented skid, tested before shipmentDP and static pressure transmitters, RTD, manifold, impulse tubing and flow computer with AGA-8 and ISO 5167-2 in firmware, hydro tested, loop checked and wet calibrated at three flow points.
Selection Data, Field Cases and Questions Engineers Ask
Case 1 - Transmission to distribution custody point
Project City gate custody transfer metering replacement
Industry Gas transmission and distribution
Location Bursa, Turkey
Line and service DN150, inlet 2.5 MPa reduced to 0.4 MPa, peak 63,000 Nm3/h
Fluid condition Pipeline quality natural gas, 41.2 MJ/Nm3, composition stable
Problem on site Monthly energy figures from the transmission operator and the distributor differed by 0.9%; the two sides used different correction methods and invoices were disputed for two consecutive quarters
Configuration supplied DN150 AGA-3 meter run with 18D/5D straight lengths, 316 SS plate at beta 0.55, senior orifice fitting, DP and static pressure transmitters, PT100, flow computer with AGA-8 and AGA-3 corrections
Commissioning Wet calibrated as a matched set, then verified on site with a transfer standard at three flow points in the presence of both parties
Measured result Discrepancy reduced to 0.2%; the first monthly settlement under the new meter was accepted by both parties without dispute, and no further disputes were raised over the following year
Delivery 9 weeks from drawing approval, third party witnessed calibration included
Case 2 - Fuel gas metering for a combined cycle power plant
Project Fuel gas metering and heat rate calculation, 2 x 135 MW unit
Industry Power generation
Location Jawa Timur, Indonesia
Line and service DN200, 3.0 MPa, 46 C, 71,000 Nm3/h design flow
Fluid condition Natural gas with variable C3+ content depending on supply source
Problem on site Vortex meters on the fuel gas header lost accuracy below 60% load, so heat rate could only be closed at full load and the operator could not demonstrate fuel consumption per MWh to the dispatcher
Configuration supplied Two parallel DN200 meter runs with senior fittings and a common flow computer, changeover logic so one run covers low load and both cover peak, AGA-8 compressibility with on-line composition input
Commissioning Each run dimensionally verified and wet calibrated; cross-check run against run at 50% load before handover
Measured result Heat rate calculation extended down to 35% load; the new metering exposed a passing bypass valve, worth 1.8% of fuel gas, corrected in the first quarter
Delivery 11 weeks for both runs, including spare plates and gasket sets
Technical parameters
Parameter Specification
Line size DN50 to DN400 (2 in to 16 in), larger by arrangement
Pressure rating ANSI Class 300, 600 or 900, raised face or ring joint
Design pressure Up to 10 MPa standard, higher on request
Governing standards AGA Report No.3, API MPMS 14.3, ISO 5167-2
Beta ratio 0.20 to 0.75, selected for the contracted flow band
Plate 316 SS, 3.175 mm thick, 45 degree bevel, bore stamped with heat number
Meter tube A106 Gr.B or 316L, honed or pickled, ID measured at four points
Straight lengths 18D upstream and 5D downstream typical, built to the beta and fitting table
Instrumentation DP and static pressure transmitters, PT100, flow computer with AGA-8 and ISO 5167-2
System accuracy plus or minus 0.5% of reading, repeatability plus or minus 0.1%
How This Meter Run Compares With Other Gas Flow Elements

The comparison below is about how much of a contract each option can support, not only about accuracy on a datasheet.

Option Documented geometry and traceability Turndown Where it wins
This AGA-3 meter run Full: measured tube ID, dimensional report, stamped plate, matched set calibration 3:1 to 5:1 Custody transfer and plant fuel gas where the uncertainty has to be defensible to a second party
ASME orifice gas flowmeter Plate and carrier certificates, geometry partly field dependent 3:1 General gas service, sub-metering and internal allocation
Standard stainless orifice plate Plate certificate only 3:1 Indication duty, combustion air, nitrogen and utility gas headers
Pitot tube flowmeter Probe calibration, single tapping 3:1 to 5:1 Large ducts and stacks where permanent loss and installation cost dominate
Venturi flowmeter Body dimensional certificate, higher capital cost 3:1 High volume transmission lines where pressure loss is worth paying to remove

Related pages: ASME orifice gas flowmeter · standard stainless steel orifice plate flowmeter · pitot tube flowmeter for large gas ducts · Venturi flowmeter for low permanent pressure loss · all orifice plate flowmeters · temperature compensated steam orifice plate flowmeter · sanitary tri clamp orifice plate flowmeter

What does a meter run include that a plate and a flow computer do not?

A plate and a flow computer are two components; a meter run is a geometry. It includes the honed upstream and downstream tube sections cut to the length the beta ratio and upstream fitting require, the orifice fitting that holds the plate concentric and square to the bore, corner taps drilled to position, and a dimensional report recording the actual internal diameter the flow computer is configured with. Buy the parts separately and the equation's assumptions become an installation contractor's judgement. Buy the run and the manufacturer signs for the discharge coefficient that the contract was written around, with the paperwork to support it.

Can AGA-3 metering be used for hydrogen or biomethane blends?

For biomethane the answer is generally yes, provided the composition is known well enough to evaluate density and the compressibility factor correctly, since the physical measurement itself is unchanged. For hydrogen the answer is no above a few percent by volume. The published discharge coefficient correlations were derived on natural gas, and the expansibility term and Reynolds number behaviour depart once the hydrogen fraction rises. Hydrogen blending beyond roughly 10-20% by volume needs a method written for it, such as AGA Report No.11 or ISO 20765 based calculation, plus a measurement principle that does not rely on the natural gas coefficient tables. Specify the composition at the enquiry stage rather than after the run is built.

How often should the orifice plate be inspected or replaced?

API MPMS 14.3 treats annual inspection as the baseline, and more often where the gas carries liquids or solids. The checks that matter are the bore diameter against its stamped value, the sharpness of the upstream edge, flatness, and any deposit or erosion on the upstream face. An edge radius that has grown beyond about 0.05 mm, a bore that is out of round, or a plate that has bowed is a replacement, not a repair. Keep a spare plate and gasket set on site: a plate costs a fraction of the gas lost while a disputed meter is investigated, and swapping one is a ten minute job with a dual chamber fitting.

Why does my orifice meter under-read at low flow?

Because differential pressure follows the square of flow, resolution collapses as flow falls. Below roughly 30% of the transmitter span a small zero shift or a millivolt of noise translates into a large flow error, and below 10% the reading is indicative at best. Add to that a plate sized for peak winter demand running at summer flows and the effect compounds. The remedies are structural rather than electronic: size the bore for the normal flow band instead of the maximum, install two parallel runs with changeover logic for strongly seasonal loads, or lower the DP span and accept a narrower upper range. Re-ranging a transmitter does not restore turndown that the geometry never had.

Product Highlights

AGA-3 orifice meter run built as one accountable assembly: honed meter tube, dual chamber orifice fitting, stamped 316 SS plate, DP and static pressure transmitters, RTD and AGA-8 flow computer. Hydro tested and wet calibrated before shipment. Ask for the sizing and uncertainty report.

RELATED PRODUCTS
Quality Petroleum Radar Level Gauge 26GHz High Temperature Industrial factory

Petroleum Radar Level Gauge 26GHz High Temperature Industrial

Petroleum Radar Level Gauge brings 26GHz radar precision and high-temperature capability to oil storage tank measurement. Every millimeter of level is tracked accurately to prevent inventory loss and safety risk. Inquire now for specifications.

Quality Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor factory

Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor

Portable FMCW Radar Level Gauge brings laboratory-grade radar measurement to any tank in the plant or field. With IP67 protection and quick setup, it delivers accurate liquid level readings without permanent installation. Contact us for specifications.

Quality Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay factory

Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay

Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.

Quality Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement factory

Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement

Universal Gauge Pressure Transmitter measures pressure relative to the atmosphere for pump discharge, line pressure, tank head and filter differential applications. With 4-20mA output, it suits oil, water and gas measurement. Contact us for range options.

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.