Side-Mounted Magnetic Float Level Switch for Pump Dry-Run Alarm

Brand Name: QINWEIYB
Model Number: QWYB-UZ616
Place of Origin: China
Minimum Order Quantity: 1 Set
Price: Negotiable
Supply Ability: 100 Sets per Month

Product Details


Mounting Type: Side-mounted Maximum Working Pressure: 2.0 MPa
Media Temperature: -10 To 120 °C Minimum Specific Gravity: 0.5
Wetted Material: 304 / 316L / PP / PVDF Contact Type: SPDT / DPDT Reed
Contact Rating: 0.5 A At 220 V AC Repeatability: ±3 Mm
Enclosure: IP65 / IP67 / Ex D IIC T6 Process Connection: 1/2 Inch To 1 Inch NPT Or DN25 / DN50
Highlight

magnetic float level switch

,

side mounted float switch

,

pump dry run switch

Product Description

A pump that runs dry for ninety seconds usually costs more than the switch that should have stopped it — mechanical seal, shaft, and sometimes the motor winding as well. This side-mounted magnetic float level switch exists to close that loop: one nozzle on the tank wall, a stainless steel float that rises and falls with the liquid, and a dry-contact output that stops the pump, opens a fill valve or raises a high-level alarm.

Set point adjustable across the float travel · 2.0 MPa standard rating · SPDT or DPDT contacts · explosion-proof and high-temperature versions · compatible with water, diesel, glycol and most chemical solutions.

Why Dry-Run Damage and Overflow Keep Happening

Almost every plant that loses a pump to dry running already has a level device on the tank. The device is usually a float ball in a cage, a tuning fork or a capacitance probe, and it fails for reasons nobody planned for: suspended solids jam the float, foam gives a false high reading, the probe coats with scale, or the electronics drift until the set point means nothing.

The consequences are asymmetric. A missed low-level trip destroys a mechanical seal and stops production for half a day. A missed high-level alarm overflows a tank, and in a chemical plant that becomes an environmental report instead of a maintenance ticket. Meanwhile purchasing is asked to solve a safety problem with the cheapest available component, which is why the same failure returns on a predictable cycle.

What a plant actually needs is a switch with no electronics in the sensing path, no narrow passages to block, and a contact that wires into the existing MCC or DCS without a transducer. That is the engineering brief for this switch: mechanical, magnetic, adjustable, and rebuildable in place.

How the Magnetic Switch Detects the Set Point

The switch mounts through a single nozzle in the tank wall. A short stem carries a float that pivots or slides; as the liquid rises, the float travels through an arc or a vertical stroke. A permanent magnet inside the float assembly moves with it, and when the magnet reaches the reed contact sealed in the stem, the contact closes or opens.

Because the magnet and the reed never touch, there is no wear surface and no seal to leak at the switching point — the process fluid stays inside the tank while the electrical circuit stays outside it. The reed capsule is glass-sealed and potted, so humidity, condensation and corrosive vapour inside the terminal housing never reach the contact.

The set point is adjusted mechanically by sliding the housing along the stem and locking it with a grub screw, or fixed at the factory for repeat orders. Hysteresis comes from float geometry and reed sensitivity rather than from an electronic delay, so the switch does not chatter when the surface ripples. One unit can carry two independent contacts — typically one for pump stop and one for alarm — and because the contacts are dry, the same switch drives a 24 V DC PLC input or a 220 V AC contactor coil.

Mechanical Design Choices That Prevent Field Failures

Stem and float are 304 or 316L stainless steel in the standard version, with PP, PVDF and PTFE options for acids, and brass or nickel-plated versions for diesel and lube oil. The float is a sealed welded body with no foam filling, so it cannot absorb liquid and sink after long immersion — a failure mode that quietly disables older foam-float designs.

The pivot or guide uses a hardened pin with a self-lubricating bushing, and the stem is smooth, with no slots or cages where fibrous material can catch. On dirty service, a slightly larger float with a longer stroke tolerates a buildup film without losing the set point.

Electrical termination is a DIN terminal block inside a die-cast aluminium or engineering-plastic housing rated IP65 or IP67, with a cable gland for 6–12 mm cable. Explosion-proof models use a flameproof housing with Ex d IIC T6 certification for classified areas around solvent and fuel storage. High-temperature versions replace the standard magnet with a samarium-cobalt grade that holds strength to 150 °C, and a remote-housing version keeps the terminal block away from the hot tank wall.

Wiring Configurations for Pump Control and Alarm Duty

The most common requirement is a single switch that stops the pump at low level and allows restart on refill. Wire the SPDT common to the contactor coil supply, normally-open to hold the pump on, and place the set point about 150 mm above the suction nozzle to leave a working buffer.

For a fill application, invert the logic: use normally-closed on rising level to close the inlet valve. For a high-level alarm, use the second contact in the same housing and route it to a separate input card, so the alarm does not depend on the pump circuit.

Three wiring rules prevent most commissioning call-outs: keep the switch cable away from VFD output cables to avoid induced noise, respect the contact rating (0.5 A at 220 V AC is typical for a reed, so large motor loads need a contactor or interposing relay), and always test the set points with the real medium when its specific gravity differs from water by more than 0.15.

Pain Point Comparison: Two Working Conditions
Pain pointCondition A — pump sump with suspended solidsCondition B — closed fuel or chemical tank
Typical failure of a conventional deviceCage float jams on rags and grit; the pump runs dry while the switch still shows “up”Fumes attack the terminal block, the contact corrodes closed, and the pump never stops
Behaviour of this magnetic switchSmooth stem with no cage; the large float keeps working under a solids film and lifts out for cleaning in minutesGlass-sealed reed and potted terminal block, with an Ex d housing for classified areas
Set point stabilityMechanical hysteresis absorbs ripple from the incoming flowRepeatability ±3 mm, so start and stop levels stay constant with no electronic tuning
Maintenance action requiredRemove the float, wipe the stem, refit — no specialist toolsAnnual contact resistance check with a multimeter during shutdown
Cost of a missed tripMechanical seal and possibly the pump shaftOverflow, product loss and an environmental incident report
Integration effortDry contact straight into the existing MCC control circuitTwo isolated contacts allow separate alarm and shutdown paths
Application Scenarios

The scenarios below describe typical installations and the configuration logic behind them, summarised from field feedback. Performance statements are qualitative and depend on site conditions, pipework layout and operating discipline.

Scenario 1 — Municipal wastewater lift station
  • Industry: Municipal wastewater collection and pumping
  • Site profile: Coastal South-East Asia — wet, saline air
  • Equipment: Submersible sewage pumps in a shallow wet well
  • Medium: Raw sewage with grit, rags and grease
  • Operating conditions: Atmospheric pressure, warm ambient, pH 6–8, frequent level cycling
  • Challenge: Cage-type float switches jammed repeatedly with rags, and pumps were replaced after dry-run seal failure
  • Configuration: Side-mounted magnetic float switch, 316L stem, 120 mm stroke, dual SPDT contacts, IP67 housing, pump-stop set point 250 mm above suction
  • Solution highlights: Cage-free stem eliminated rag catching; two isolated contacts drove pump stop and high-level telemetry on separate circuits
  • Field outcome: Uninterrupted operation with no further pump replacement, and rag-related call-outs no longer a routine event
  • Service: Float wiped during routine station cleaning, with a spare float and reed kit held on site
Scenario 2 — Diesel day tank, standby generator set
  • Industry: Telecom data centre standby power
  • Site profile: West Africa — generator room with consistently high ambient temperature
  • Equipment: Diesel day tank feeding standby generator sets
  • Medium: Automotive diesel with occasional water and particulate contamination
  • Operating conditions: Atmospheric pressure, tank refilled daily by transfer pump, continuous genset vibration
  • Challenge: A capacitive probe drifted and produced nuisance low-fuel alarms, then missed a genuine low-level event during a grid outage
  • Configuration: Side-mounted magnetic float switch, nickel-plated brass body, single SPDT contact, IP65 housing, set point at 25% tank height wired to the transfer pump circuit
  • Solution highlights: Mechanical set point immune to fuel dielectric change and genset vibration; the contact drives the auto-fill pump through a relay
  • Field outcome: Nuisance alarms eliminated, the day tank held level through an extended grid outage, and no dry transfer-pump events were reported afterwards
  • Service: Set point re-verified after tank cleaning, no parts replaced
Six Advantages That Decide the Purchase
  • No electronics in the sensing path: The set point is fixed by float geometry and a sealed reed, so there is no zero or span to drift and no firmware to update.
  • Adjustable set point on site: The housing slides and locks on the stem, letting commissioning engineers tune start and stop levels without ordering a new part.
  • Cage-free design for dirty service: A smooth stem and a large welded float tolerate grit, grease and fibrous material far better than a caged float ball.
  • Dry contacts for any control system: SPDT or DPDT outputs wire directly into PLC inputs, MCC contactors, annunciators or RTUs, with no transducer and no power supply.
  • Explosion-proof and high-temperature options: Ex d IIC T6 housings cover fuel and solvent areas, while high-temperature floats handle media to 150 °C and remote housings keep terminals cool.
  • Low cost of ownership: Reed capsules and floats are field-replaceable spares, and the unit typically costs a fraction of a guided-wave or radar switch with comparable function.
Technical Specifications
ParameterSpecification
Mounting typeSide-mounted, horizontal or angled nozzle; top-mounted version for vertical tanks
Maximum working pressure2.0 MPa standard; 4.0 MPa on request
Media temperature−10 °C to 120 °C standard; to 150 °C with high-temperature float
Media specific gravity0.5 minimum for the standard float; lighter media on request
Wetted materials304 / 316L stainless steel, brass, PP, PVDF, PTFE-lined options
Contact typeSPDT or DPDT reed, dry contact, single or dual set point
Contact rating0.5 A at 220 V AC / 24 V DC resistive; interposing relay recommended above this
Repeatability±3 mm at a fixed set point
EnclosureIP65 standard; IP67 and Ex d IIC T6 explosion-proof options
Process connection1/2″ to 1″ NPT or BSP, or flanged DN25 / DN50
SEO FAQ

Q1. Can one magnetic float switch control both the pump stop and the high-level alarm?
Yes. Dual-contact versions carry two independent reed capsules in the same stem, each with its own set point, so one nozzle provides a pump-stop contact at low level and an alarm contact at high level. Keep the two circuits electrically isolated and route them to different input cards, so a fault in the alarm wiring cannot stop the pump and a fault in the pump circuit cannot mask the alarm. If the tank also needs a visible level reading for routine inspection, add a small bicolor gauge on a second nozzle, or combine the switch with a magnetic level gauge. This arrangement is standard in fuel fill stations where operators want both a local reading and a working pump interlock.

Q2. Will suspended solids or viscous media cause the float to stick?
The main cause of sticking is a caged or slotted design, where solids pack into the guide. A side-mounted float on a smooth stainless stem avoids that trap and keeps working under a thin film of solids. For genuinely viscous media such as slurry or molasses, specify the larger float with a longer stroke, reduce the switching frequency, or move to a non-contact device. In municipal sewage duty a float with a wide working arc and no bottom bearing is normally sufficient. Where heavy grease is present, a nozzle extension that lifts the switch clear of the grease layer extends the cleaning interval considerably, and the float can simply be wiped during routine station maintenance.

Q3. What is the difference between a magnetic float switch and a mechanical float ball switch?
A mechanical float ball switch uses a pivoting arm and a micro switch, with the electrical contact in a housing the liquid can reach if a seal fails. A magnetic float switch keeps the contact sealed inside a glass reed capsule, so fluid and circuit never meet and the switching element has no wearing parts. Magnetics also allow a much shorter stroke, which makes set-point repeatability tighter and tolerates higher pressure in a compact body. The trade-off is a lower contact rating, so large motor loads must be switched through a relay — a small extra cost that avoids welding the contacts on a 5 kW pump circuit.

Q4. How should the set points be chosen so the pump is genuinely protected?
Set the pump-stop point at least 150 mm above the suction nozzle, and never closer than ten pipe diameters, so a vortex cannot pull air into the suction before the switch trips. Allow for pump run-down time after the contact opens and add a 100–150 mm buffer for that. On the fill side, set the start point low enough to prevent short cycling — a working band of at least 25% of tank height is a sensible default for 40-cycle-per-day duty. Finally, verify the set points with the actual liquid, because a float calibrated on water will trip at a different level in a medium with a specific gravity below 0.8.

Related Level Instruments

For a visible scale on the same vessel, pair this switch with the bicolor magnetic flapper level gauge rated to 4.0 MPa. If the control system needs a continuous signal rather than a trip, choose the HART magnetic level transmitter. For acid and alkali dosing tanks, the PP magnetic float level sensor uses the same magnetic principle in a plastic body. For heated bitumen service, see the steam-jacketed level gauge, because solidifying media cannot be switched reliably by a float.

Product Highlights

Side-mounted magnetic float level switch for pump dry-run protection and high or low level alarm. Mechanical set point, SPDT/DPDT dry contacts, 2.0 MPa rating, explosion-proof option. Request a wiring diagram and quote.

RELATED PRODUCTS
Quality Petroleum Radar Level Gauge 26GHz High Temperature Industrial factory

Petroleum Radar Level Gauge 26GHz High Temperature Industrial

Petroleum Radar Level Gauge brings 26GHz radar precision and high-temperature capability to oil storage tank measurement. Every millimeter of level is tracked accurately to prevent inventory loss and safety risk. Inquire now for specifications.

Quality Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor factory

Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor

Portable FMCW Radar Level Gauge brings laboratory-grade radar measurement to any tank in the plant or field. With IP67 protection and quick setup, it delivers accurate liquid level readings without permanent installation. Contact us for specifications.

Quality Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay factory

Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay

Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.

Quality Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement factory

Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement

Universal Gauge Pressure Transmitter measures pressure relative to the atmosphere for pump discharge, line pressure, tank head and filter differential applications. With 4-20mA output, it suits oil, water and gas measurement. Contact us for range options.

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.