Quality Magnetic Level Transmitter 4-20 mA HART Continuous Tank Feedback factory
<
Quality Magnetic Level Transmitter 4-20 mA HART Continuous Tank Feedback factory
Quality Magnetic Level Transmitter 4-20 mA HART Continuous Tank Feedback factory
Quality Magnetic Level Transmitter 4-20 mA HART Continuous Tank Feedback factory
>

Magnetic Level Transmitter 4-20 mA HART Continuous Tank Feedback

Brand Name: QINWEIYB
Model Number: QWYB-UZ617
Place of Origin: China
Minimum Order Quantity: 1 Set
Price: Negotiable
Supply Ability: 100 Sets per Month

Product Details


Measuring Range: 300-6000 Mm Output Signal: 4-20 MA Two-wire With HART 7
Loop Supply: 12-36 V DC Accuracy: ±5 Mm
Damping: 0-30 S Configurable Process Pressure: Up To 4.0 MPa
Process Temperature: -40 To 350 °C Wetted Material: 316L / PTFE-lined
Protection: IP66 / IP67, Ex Ia IIC T6 Local Display: Bicolor Indicator / LCD
Highlight

magnetic level transmitter

,

4-20mA level transmitter

,

hart tank level sensor

Product Description

Most storage tanks already have a level device. What they usually lack is a level number that the control room can trust at two in the morning: one that matches the mechanical gauge on the wall, survives a dirty medium, and arrives at the PLC without an engineer walking out to the bund to read a scale. This magnetic level transmitter provides exactly that — a magnetostrictive-style measurement on the same float that drives a local indicator, converted to a continuous 4-20 mA signal with HART digital communication on top.

Range 300–6000 mm · 4-20 mA two-wire output · HART 7 · accuracy ±5 mm · 24 V DC loop powered · local LCD and bicolor indicator available on the same chamber · 316L, PTFE-lined and jacketed chamber options.

Why Continuous Level Data Still Matters When a Gauge Already Exists

A mechanical gauge answers the question “what is the level now” for the person standing in front of it. It does not answer “how fast is the tank filling”, “what was the level when the transfer pump started”, or “will we run out before the next delivery”. Those questions are answered by a trend, and a trend needs a signal.

Plants usually discover the gap in one of three ways. An operator misses a high-level condition because nobody checks the tank at night. A batch record needs level at start and end, and the shift writes down a number from a sight glass that has drifted. Or an ERP or inventory system is introduced and there is no instrument to feed it. Retrofitting a radar or a differential pressure transmitter then runs into the real constraint: the tank is in service, the nozzle does not exist, and the medium coats or crystallises on anything inserted into it.

A magnetic transmitter solves the retrofit problem because it does not need a new nozzle and does not need the medium to be clean. It rides on the float that is already inside a magnetic gauge chamber, so installation is a mechanical job on an existing connection rather than a hot work and process shutdown job.

How the Float Position Becomes a 4-20 mA Signal

The transmitter is a sealed probe that runs parallel to the gauge chamber. Inside it, a waveguide or a chain of precision resistors and reed elements senses the position of the float magnet through the chamber wall. As the float rises, the electronics determine the corresponding position along the probe and map it onto the configured measuring range.

A four-step process happens in the loop: the float magnet defines the physical position, the probe converts position into an electrical value, the transmitter electronics linearise it against the configured 0% and 100% points, and the output stage drives 4-20 mA around the two-wire loop. HART superimposes a digital signal on the same two wires, so a technician can read the primary variable, the percentage of range and diagnostic status from a handheld or a laptop without breaking the loop.

Because the sensing element never contacts the medium and has no moving parts of its own, coating, foam, vapour and dielectric changes do not shift the reading — the failure modes that make capacitance and DP devices drift on real tanks. The local bicolor indicator, where fitted, is driven by the same float, so the control room value and the field reading cannot disagree by more than the mechanical tolerance.

Structural and Electronic Advantages in Retrofits and New Builds

The probe is housed in a 316L stainless steel tube with a welded end cap, sealed to IP66/IP67, and connected by a potted cable entry or a standard M20 gland. Isolation between the process and the electronics is total: there is no diaphragm, no capillary and no impulse line to freeze, block or leak.

Electronically, the transmitter provides a fixed 4 mA at empty and 20 mA at full, with configurable damping from 0 to 30 seconds to smooth surface movement in agitated tanks. It operates on a 12–36 V DC loop, draws under 3.6 mA in normal operation, and reports sensor failure or out-of-range conditions through HART diagnostics rather than silently freezing at the last value — a distinction that matters when the signal feeds an inventory calculation.

For hazardous areas, intrinsically safe versions with Ex ia IIC T6 certification allow the transmitter to sit inside a classified zone with an associated barrier or isolator in the safe area. For high-temperature service, the electronics are separated from the chamber by a standoff neck, so a 350 °C process does not cook the circuit board.

Commissioning: Range Setting, Damping and Loop Checks

Configure the range in the field, not on the drawing. Fill the tank to a known level, read the mechanical gauge, and set that as the reference point; then set the span at a second known level. Two-point calibration against reality takes fifteen minutes and eliminates most of the error that shows up later as an inventory discrepancy.

Set damping according to the process, not the operator's preference. A 2–5 second damping suits a quiet storage tank, 10–20 seconds suits an agitated reactor or a tank with a running transfer pump. Too little damping produces an alarm that chatters; too much hides a genuine fast fill.

Finally, perform a loop check from the field to the control system: drive the output to 4, 12 and 20 mA, confirm the values at the PLC or DCS, and verify that the engineering unit and decimal point in the control system match the transmitter configuration. Most “instrument faults” reported in the first week are actually unit mismatches between a HART device configured in metres and a SCADA tag scaled in millimetres.

Pain Point Comparison: Two Working Conditions
Pain pointCondition A — dirty or crystallising medium in a live tankCondition B — agitated tank with foam and vapour
Typical failure of a DP or capacitance deviceImpulse lines block, diaphragm coats, reading freezes or drifts downwardFoam is read as liquid; dielectric change from vapour shifts the zero
Behaviour of this magnetic transmitterMagnet position is sensed through the chamber wall — no wetted electronics and nothing to blockFloat follows true liquid level; foam and vapour do not affect the magnetic field
Retrofit effortNo new nozzle: mounts on the existing magnetic gauge chamberDamping and range configurable on site through HART, without opening the tank
Field verificationLocal bicolor indicator and the mA signal share one float, so cross-checks are instantDiagnostics report a failed sensor instead of holding the last value silently
Maintenance intervalNo impulse lines to flush; annual loop check onlyNo re-zeroing after product change, unlike capacitance probes
Cost of getting it wrongWrong inventory figures and unplanned tank cleaningOverfill, foam carry-over into the downstream line, batch rework
Application Scenarios

The scenarios below describe typical installations and the configuration logic behind them, summarised from field feedback. Performance statements are qualitative and depend on site conditions, pipework layout and operating discipline.

Scenario 1 — Solvent storage tank farm, coatings plant
  • Industry: Industrial coatings and resins manufacturing
  • Site profile: Central Europe — indoor tank farm, Zone 1 classified area
  • Equipment: Multiple solvent storage tanks already fitted with magnetic level gauges
  • Medium: Xylene, butyl acetate and mixed solvent blends
  • Operating conditions: Atmospheric pressure, seasonal ambient range, tanks filled by road tanker on a weekly cycle
  • Challenge: Inventory was calculated from dip readings and delivery notes, producing a recurring stock variance at each reconciliation; no nozzle was available for a radar without hot work
  • Configuration: 4-20 mA HART transmitter on the existing gauge chamber, range 0–2600 mm, Ex ia IIC T6, 24 V DC loop, 5 s damping, bicolor indicator retained on the same chamber
  • Solution highlights: Transmitters fitted during normal tank rotation with no hot work; HART allowed every unit to be ranged from one handheld
  • Field outcome: Stock variance narrowed to a level accepted by finance, and the tanker unloading sequence now triggers automatic reconciliation
  • Service: Annual loop calibration, HART configuration backup stored by tag number
Scenario 2 — Dissolved air flotation tank, water treatment works
  • Industry: Municipal drinking water treatment
  • Site profile: Subtropical region — outdoor installation, hot summers
  • Equipment: Deep contact tank upstream of the filter gallery
  • Medium: Clarified water with residual coagulant and occasional algae
  • Operating conditions: Atmospheric pressure, continuous flow with surface turbulence, level held in a narrow control band
  • Challenge: An ultrasonic device lost echo on foam during algae blooms, and operators lost the level signal for extended periods
  • Configuration: HART magnetic transmitter, range 0–3000 mm, 316L chamber with matching gauge length, IP67 housing, 15 s damping, 4-20 mA into the existing PLC analogue card
  • Solution highlights: Magnetic sensing unaffected by foam and algae film; damping smoothed the signal from the flume inlet turbulence
  • Field outcome: Level signal retained through successive algae seasons, and chemical dosing now trimmed from the level trend rather than a fixed timer
  • Service: Probe and float inspected annually during the tank drain-down, no recalibration needed
Six Advantages That Justify the Instrument Budget
  • Direct retrofit on an existing magnetic gauge: No new vessel penetration, no hot work, and installation is completed during a normal tank rotation instead of a shutdown.
  • Sensing immune to medium condition: Coating, foam, vapour and dielectric changes do not shift the reading, which removes the recurring calibration loop that DP and capacitance devices demand.
  • One float, two outputs: The 4-20 mA signal and the local bicolor indicator read from the same float, so field and control room values stay consistent.
  • HART diagnostics instead of silent failure: Sensor faults and out-of-range conditions are reported digitally, so a frozen 12 mA is never mistaken for a stable tank.
  • Hazardous area and high-temperature ready: Ex ia IIC T6 intrinsic safety for classified zones, and a standoff neck that keeps electronics cool on chambers up to 350 °C.
  • Simple two-wire loop: 24 V DC loop power over standard shielded pair, compatible with existing PLC analogue cards, RTUs and telemetry outstations.
Technical Specifications
ParameterSpecification
Measuring range300–6000 mm, configured to the gauge centre-to-centre distance
Output signal4-20 mA, two-wire, HART 7 digital communication superimposed
Loop supply12–36 V DC, loop powered; typical consumption below 3.6 mA
Accuracy±5 mm of the indicated float position
Damping0–30 s, configurable through HART
Process pressureUp to 4.0 MPa (chamber rating dependent)
Process temperature−40 °C to 350 °C with standoff neck; −40 °C to 120 °C direct mount
Wetted / housing materials316L probe and chamber standard; PTFE-lined and titanium options
Protection and certificationIP66 / IP67; Ex ia IIC T6 intrinsically safe version; CE marked
Local display optionBicolor flapper indicator, LCD percentage display, or both on the same chamber
SEO FAQ

Q1. Can this transmitter be added to a magnetic level gauge that is already installed?
In most cases yes. The transmitter probe is designed to clamp alongside existing chamber, using the same float magnet that drives the bicolor indicator, so no new nozzle and no welding are needed. The work is done with the tank isolated and drained only if the probe must enter the chamber; clamp-on versions can be fitted with the tank in service. Confirm two dimensions before ordering: the chamber outside diameter and the centre-to-centre distance, because those set the clamp size and the electrical range. If the existing gauge has a plastic or non-magnetic housing, a new 316L chamber is required, since the probe must sense the float through a non-ferrous, non-magnetic wall.

Q2. How does HART help compared with a plain 4-20 mA transmitter?
A plain 4-20 mA loop tells the control system one number and nothing else. HART carries the same analogue signal but also a digital channel on the same two wires, so a technician can read the measured value, the percentage of range, the sensor temperature and diagnostic status without breaking the loop or opening the tank. Configuration changes such as range, damping and units can be made from a handheld or from the control system, and a fault is reported as a fault rather than a plausible-looking milliamp value. For plants with many tanks, HART also allows all devices to be documented and backed up by tag number, which shortens commissioning and simplifies spare-part management.

Q3. What accuracy can be expected and where does the error come from?
Expect about ±5 mm on the electrical output, with the largest contribution coming from the float's own buoyancy response rather than the electronics. In a medium whose density differs from the design value, the float sits at a slightly different height, so always specify the operating specific gravity when ordering. A second contribution is mechanical: if the chamber is not vertical, or if the float guide is coated, the float can lag the surface. Third is installation — a range configured from drawings instead of measured levels will produce a constant offset. Two-point calibration against the mechanical gauge during commissioning removes that offset and is the single most effective accuracy improvement available.

Q4. How is the transmitter maintained and what spares should be stocked?
Maintenance is an annual loop check: verify 4, 12 and 20 mA at the control system, compare the reading with the local indicator, and inspect the probe cable entry for water ingress. There is nothing to clean inside the probe and no impulse line to flush. Keep one spare transmitter electronics module and one float on site for a tank farm of up to twenty units; the probe itself rarely fails, and the float is the part that eventually wears or coats. If the site uses HART, store a configuration backup per tag so a replacement module can be restored in minutes rather than re-ranged from scratch during a production stoppage.

Related Level Instruments

Where only a local visual reading is required, the bicolor magnetic flapper level gauge is the lower-cost option that uses the identical chamber and float. For simple pump interlocks and alarms, the side-mounted magnetic float level switch provides dry contacts without any electronics. For acid and caustic dosing tanks where stainless steel is not acceptable, the PP magnetic float level sensor is the compatible choice. For hot bitumen and asphalt tanks, the steam-jacketed magnetic level gauge can be supplied with the same HART transmitter mounted on the jacketed chamber.

Product Highlights

HART magnetic level transmitter delivering continuous 4-20 mA tank level to DCS and PLC loops. Retrofits onto existing magnetic gauge chambers, immune to coating and foam, Ex ia available. Request a datasheet and quote.

RELATED PRODUCTS
Quality Petroleum Radar Level Gauge 26GHz High Temperature Industrial factory

Petroleum Radar Level Gauge 26GHz High Temperature Industrial

Petroleum Radar Level Gauge brings 26GHz radar precision and high-temperature capability to oil storage tank measurement. Every millimeter of level is tracked accurately to prevent inventory loss and safety risk. Inquire now for specifications.

Quality Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor factory

Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor

Portable FMCW Radar Level Gauge brings laboratory-grade radar measurement to any tank in the plant or field. With IP67 protection and quick setup, it delivers accurate liquid level readings without permanent installation. Contact us for specifications.

Quality Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay factory

Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay

Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.

Quality Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement factory

Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement

Universal Gauge Pressure Transmitter measures pressure relative to the atmosphere for pump discharge, line pressure, tank head and filter differential applications. With 4-20mA output, it suits oil, water and gas measurement. Contact us for range options.

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.