Corrosion-Resistant PP Magnetic Float Level Sensor for Dosing Tanks

Brand Name: QINWEIYB
Model Number: QWYB-UZ618
Place of Origin: China
Minimum Order Quantity: 1 Set
Price: Negotiable
Supply Ability: 100 Sets per Month

Product Details


Stem Length: 200-1500 Mm Body Material: PP / PVDF / PTFE
Float Material: PP Or PVDF With Encapsulated Magnet Media Temperature: 0-80 °C PP, 0-120 °C PVDF
Maximum Pressure: 0.6 MPa Screw-in, 1.0 MPa Flanged Minimum Specific Gravity: 0.6
Switch Points: 1 To 4 SPDT Reed Contact Rating: 0.5 A At 220 V AC
Mounting: G2 Inch Thread / DN50 Flange Protection: IP65 / IP68
Highlight

pp float level sensor

,

plastic level switch

,

chemical tank level sensor

Product Description

In a dosing room, the level device is the part that fails first. Sodium hypochlorite bleaches polymer floats, hydrochloric acid attacks stainless stems, and the atmosphere alone corrodes a terminal block within a season. This PP magnetic float level sensor was built for that environment: a polypropylene body, a chemically inert float, and a sealed reed contact that never touches the chemical. It mounts through the tank lid, reads a small tank cleanly, and gives the dosing pump controller a signal it can act on.

Stem lengths 200–1500 mm · PP, PVDF or PTFE wetted parts · up to 4 switch points on one stem · specific gravity from 0.6 · IP65 or IP68 termination · screw-in, flange or bracket mounting.

Why Metal Level Devices Keep Failing in Dosing Rooms

The first failure is chemical. 316L stainless steel is an excellent general-purpose alloy, but it is not suitable for hydrochloric acid, sodium hypochlorite, ferric chloride or hydrofluoric acid, and even a diluted solution will pit a stainless stem within months. A device that pits does not simply read wrongly; it eventually releases the medium into the bund or the terminal housing.

The second failure is scale and crystallisation. Dosing chemicals crystallise at the neck of the tank, and any sensor with a moving arm, a narrow cage or an exposed diaphragm will be locked in place by a salt bridge. A float that has to be freed with a spanner every six weeks is not instrumentation, it is maintenance debt.

The third failure is electrical. Vapour from hypochlorite or acid destroys a standard terminal block, and a corroded contact either sticks closed — the tank overfills — or sticks open, and the pump runs dry. The economic case for specifying the right material up front is straightforward: one corroded sensor typically costs the price of five correct ones once you add the downtime and the bund cleanup.

A plastic-bodied magnetic sensor addresses all three at once, and that is why it has become the default on chemical dosing skids, electroplating lines, water treatment plants and laboratory waste neutralisation tanks.

How a Plastic-Bodied Magnetic Sensor Works Without Wetted Metal

The sensor consists of a hollow PP or PVDF stem with a sliding float around it. The float contains an encapsulated magnet, and inside the stem, at the chosen set points, sealed reed contacts are fixed in position and potted against moisture.

As the liquid level changes, the float slides along the stem. When it reaches a contact position, the magnetic field closes or opens the reed, and the signal passes through a cable or a DIN plug to the controller. No part of the electrical circuit is exposed to the chemical, and no metal is wetted — the only materials in contact with the medium are the plastic stem, the plastic float and the mounting seal.

This arrangement gives three practical benefits in a dosing room. The set points are fixed and repeatable, because the float slides on a straight stem with a defined stroke. Multiple contacts on one stem give low, high and high-high signals from a single tank opening, which matters on small tanks where nozzles are scarce. And the whole assembly can be lifted out for cleaning without disconnecting the pipework or draining the tank.

Structural Advantages: Material, Sealing and Mounting

The standard body is polypropylene, which handles hydrochloric acid, sodium hypochlorite, caustic soda, ferric chloride and most plating solutions up to 80 °C. For stronger oxidisers or higher temperature, PVDF extends the range to 120 °C with better resistance to attack, and PTFE is used for the most aggressive media.

The float is a single-piece moulded body with no foam filling, so it cannot become waterlogged and sink after long immersion. The magnet is fully encapsulated, so there is no exposed metal to corrode and no path for the medium to reach the magnet.

Sealing is the detail that separates a reliable installation from a leaking one. Screw-in versions use a moulded PP thread with an EPDM or FKM gasket; flange versions use a PP or PVC flange with a full-face gasket, so the sealing force is spread and the tank lid is not distorted. Termination is a PP or PVDF junction box rated IP65 for indoor mounting and IP68 for tanks that are washed down or submerged, with a cable gland sized for the site's cable.

Mounting is by tank lid thread (G2″ is common on dosing tanks), by a DN50 flange, or by a stainless bracket where the lid cannot be modified. A slip-fit collar on the stem allows the switching band to be adjusted after installation, so commissioning does not depend on the tank being empty.

Choosing Stem Length, Specific Gravity and Output Type

Stem length should be the distance from the mounting point to roughly 50 mm above the tank bottom, so the float stays inside its guide at low level and the assembly does not touch the sludge layer. On a 1000 mm dosing tank, a 900 mm stem is normal.

The float must be matched to the liquid density. A standard PP float works down to specific gravity 0.8; for light solvents, methanol or dilute acids near the density of water, a larger or ballasted float is needed. Specify the actual working density, not the pure chemical density, because dosing tanks usually hold diluted solutions.

Output choice is driven by the controller. A single SPDT contact covers a low-level pump cut-out. Two contacts cover low and high alarm. Three or four contacts allow a fill valve, a low-level alarm, a high-level alarm and a high-high shutdown on one stem. Contacts are dry, so they work with 24 V DC PLC inputs, 230 V AC contactor circuits and battery-backed alarm panels — with an interposing relay wherever the load exceeds 0.5 A.

Pain Point Comparison: Two Working Conditions
Pain pointCondition A — sodium hypochlorite dosing tankCondition B — hydrochloric acid day tank
What happens with a stainless steel deviceStem and float pit and discolour within months; contact housing fills with vapour and failsRapid pitting corrosion at the liquid line and at the weld; the stem eventually perforates
What happens with this PP sensorPP body is unaffected by hypochlorite within its temperature rating; encapsulated magnet is not wettedPP or PVDF body resists HCl at dosing concentrations; no metal in the liquid path
Effect of crystallisation at the tank neckFloat slides on a straight stem and clears salt bridges; the assembly lifts out for rinsingSmooth stem and single-piece float leave no cage for crystals to lock
Multiple signals from one openingUp to four contacts on one stem: low cut-out, fill control, high alarm, high-high shutdownTwo contacts on a short stem give low and high alarm without drilling a second lid
Typical service life in dosing dutyThree to five years with annual rinsingThree years or more, with a replacement float as the only consumable
Cost of the wrong choiceBund contamination, pump damage and an environmental reportTank lid corrosion, leaking gland and unplanned dosing line shutdown
Application Scenarios

The scenarios below describe typical installations and the configuration logic behind them, summarised from field feedback. Performance statements are qualitative and depend on site conditions, pipework layout and operating discipline.

Scenario 1 — Electroplating line dosing tanks
  • Industry: Metal surface finishing and electroplating
  • Site profile: South-East Asia — high humidity, open-sided workshop
  • Equipment: A group of small dosing tanks for acid, caustic and additive solutions
  • Medium: Hydrochloric acid, sodium hydroxide and plating additives at dosing concentrations
  • Operating conditions: Atmospheric pressure, warm ambient, lids opened several times per shift
  • Challenge: Stainless float switches failed within a few months from pitting and vapour ingress, and dosing pumps were damaged by dry running
  • Configuration: PP stem 700 mm, PP float for specific gravity 1.0, G2″ screw-in mounting with EPDM gasket, two SPDT contacts (pump cut-out and high alarm), IP65 junction box
  • Solution highlights: No wetted metal; contacts sealed in the stem and potted against vapour; floats removable for rinsing without disturbing the pipework
  • Field outcome: Long service on the acid tank with only annual rinsing, no further pump dry-run incidents, and one part number standardised across the tank group
  • Service: Annual float rinse and contact resistance check, spare floats held in the maintenance store
Scenario 2 — Swimming pool disinfection plant
  • Industry: Commercial swimming pool water treatment
  • Site profile: Mediterranean region — indoor plant room, warm and humid
  • Equipment: Small sodium hypochlorite day tank feeding dosing pumps
  • Medium: Sodium hypochlorite at disinfection strength, with occasional crystallisation at the tank neck
  • Operating conditions: Atmospheric pressure, tank refilled from drums on a weekly cycle, continuous vapour in the plant room
  • Challenge: The original float sensor seized repeatedly on salt crystals, and the plant room atmosphere corroded the terminal screws until the low-level alarm stopped working
  • Configuration: PVDF stem 300 mm, PVDF float, DN50 PP flange with full-face gasket, single SPDT contact for low-level cut-out, IP68 sealed junction box with potted cable entry
  • Solution highlights: PVDF body tolerated the hypochlorite strength and the crystallisation cycle; IP68 termination removed the corrosion path entirely
  • Field outcome: No seizure and no false alarm since installation, and the refill routine now includes a visual check based on a working low-level signal
  • Service: Float rinsed at each annual shutdown, no parts replaced
Six Advantages for Chemical and Water Applications
  • No wetted metal anywhere: PP, PVDF and PTFE bodies eliminate the pitting, staining and perforation that end the life of stainless sensors in acid and hypochlorite service.
  • Encapsulated magnet, sealed contact: The magnet is fully moulded into the float and the reed is potted inside the stem, so vapour and washdown cannot reach the electrical path.
  • Up to four set points on one stem: Fill control, low cut-out, high alarm and high-high shutdown from a single tank opening — valuable on small dosing tanks with limited lid space.
  • Crystallisation-tolerant geometry: A smooth stem and one-piece float leave no cage or linkage for salt bridges to lock, and the assembly lifts out for rinsing in minutes.
  • Density-matched floats: Floats selected for specific gravity from 0.6 upward keep switching repeatable on dilute acids, light solvents and brine alike.
  • Simple, low-cost installation: G2″ screw-in, DN50 flange or bracket mounting suits standard dosing tanks, with dry contacts that connect directly to any dosing controller.
Technical Specifications
ParameterSpecification
Stem length200–1500 mm, cut to the tank depth on request
Body materialPP standard; PVDF to 120 °C; PTFE for aggressive oxidisers
Float materialPP or PVDF, single-piece moulded, encapsulated magnet
Media temperature0–80 °C (PP); 0–120 °C (PVDF)
Maximum pressure0.6 MPa for screw-in mounting; 1.0 MPa for flanged versions
Specific gravity range0.6 minimum with matched float; state working density when ordering
Switch points1 to 4 SPDT reed contacts on one stem, dry contact output
Contact rating0.5 A at 220 V AC / 24 V DC resistive; relay required for larger loads
MountingG2″ screw-in thread, DN50 PP flange, or stainless bracket
ProtectionIP65 junction box standard; IP68 potted version for washdown and submerged use
SEO FAQ

Q1. Which plastics are suitable for which chemicals in a dosing tank?
Polypropylene covers the majority of dosing duties: hydrochloric acid, sodium hypochlorite, caustic soda, ferric chloride and most plating solutions up to about 80 °C. PVDF is the next step up, for higher temperatures to 120 °C and for stronger oxidising media such as concentrated hypochlorite or mixed acid baths where PP would eventually stress-crack. PTFE is specified for the most aggressive combinations and where the highest chemical inertness is required, at a higher cost. Always confirm the working concentration and temperature, not just the chemical name, because a 5% solution and a 30% solution behave very differently. When in doubt, supply a sample of the medium and the supplier can match the body material and the float density together.

Q2. How many switch points can one sensor provide and how are they wired?
Up to four reed contacts can be mounted on a single stem, each at its own height, so one tank opening provides fill control, low-level pump cut-out, high alarm and high-high shutdown. Each contact is a dry SPDT output with its own pair of wires, so they can be routed to separate input cards on the dosing controller or PLC. Keep the switching circuits isolated from each other, and use a relay for any load above the contact rating — typically 0.5 A at 220 V AC. Where the controller has only one input, the most important contact should be the low-level cut-out, since that is the one that prevents pump damage.

Q3. Can the sensor be fitted to an existing tank without draining it?
Yes, if the tank has a top opening and the liquid level can be lowered below the mounting point during the changeover. Dosing tanks are usually small, so draining 200–500 L into a holding container is practical, and the sensor can then be screwed or bolted in place with a new gasket and the tank refilled. For tanks that cannot be drained, a slip-on bracket version can be installed from the top with the sensor hanging into the liquid, as long as the float stroke remains clear of the tank bottom. In either case, keep the junction box above the highest liquid level and loop the cable downward before it rises, so any drips run off rather than into the enclosure.

Q4. How is the sensor cleaned, and how often should it be inspected?
Lift the assembly out of the tank, rinse it with clean water, and wipe the stem with a soft cloth; do not use abrasive pads on a PP or PVDF stem. Inspect at the same interval as the dosing pump service — usually every six to twelve months in a busy plant. During inspection, check that the float slides freely over the full stroke, verify that the contacts change state with a multimeter as the float passes each set point, and look for crystal buildup at the mounting gasket. If crystals form heavily at the neck, a water flush collar or a slightly raised mounting adaptor will extend the cleaning interval considerably without changing the sensor.

Related Level Instruments

If the tank is stainless steel and rated for pressure, the side-mounted magnetic float level switch offers the same switching function in 316L with higher pressure capability. Where a continuous 4-20 mA signal is needed for inventory, the HART magnetic level transmitter can be mounted on a compatible chamber. For high-pressure or steam service, compare the bicolor magnetic flapper level gauge. For tanks holding bitumen or other media that solidify at ambient temperature, the steam-jacketed level gauge is the correct specification instead of a plastic sensor.

Product Highlights

Corrosion-resistant PP magnetic float level sensor for acid and alkali dosing tanks. No wetted metal, up to four switch points on one stem, PVDF option to 120 C. Request a model selection list.

RELATED PRODUCTS
Quality Petroleum Radar Level Gauge 26GHz High Temperature Industrial factory

Petroleum Radar Level Gauge 26GHz High Temperature Industrial

Petroleum Radar Level Gauge brings 26GHz radar precision and high-temperature capability to oil storage tank measurement. Every millimeter of level is tracked accurately to prevent inventory loss and safety risk. Inquire now for specifications.

Quality Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor factory

Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor

Portable FMCW Radar Level Gauge brings laboratory-grade radar measurement to any tank in the plant or field. With IP67 protection and quick setup, it delivers accurate liquid level readings without permanent installation. Contact us for specifications.

Quality Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay factory

Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay

Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.

Quality Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement factory

Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement

Universal Gauge Pressure Transmitter measures pressure relative to the atmosphere for pump discharge, line pressure, tank head and filter differential applications. With 4-20mA output, it suits oil, water and gas measurement. Contact us for range options.

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.