Ultrasonic Open Channel Flowmeter 4-20mA Output IP65 For Non Contact Measurement

Ultrasonic Open Channel Flowmeter 4-20mA Output IP65 For Non Contact Measurement

  • Ultrasonic Open Channel Flowmeter 4-20mA Output IP65 For Non Contact Measurement
  • Ultrasonic Open Channel Flowmeter 4-20mA Output IP65 For Non Contact Measurement
  • Ultrasonic Open Channel Flowmeter 4-20mA Output IP65 For Non Contact Measurement
  • Ultrasonic Open Channel Flowmeter 4-20mA Output IP65 For Non Contact Measurement
Ultrasonic Open Channel Flowmeter 4-20mA Output IP65 For Non Contact Measurement
Product Details:
Place of Origin: China
Brand Name: QINWEIYB
Model Number: QWLW-GY203
Payment & Shipping Terms:
Minimum Order Quantity: 1Set
Price: Negotiable
Packaging Details: Carton
Delivery Time: 5-8 work days
Payment Terms: Western Union,T/T,D/P,D/A,L/C
Supply Ability: 100PCS/Month
Contact Now
Detailed Product Description
Display Type: LCD/LED Output: 4-20mA,LCD Display,RS485
Name: Easy Installation Ultrasonic Flowmeter Power Supply: 24 VDC
Pipe Size Range: 1"~48" (25mm ~ 1200mm) Communication Interface: RS485 MODBUS
Application: Water, Oil, Chemical, Gas Flow Measurement Output Signal: 4-20mA, Pulse, RS485
Installation Method: Wall Mount Protection Rating: IP65 Or Higher
Highlight:

Non Contact Ultrasonic Open Channel Flowmeter

,

Ultrasonic Open Channel Flowmeter 4-20mA

,

Easy Installation Ultrasonic Flowmeter IP65

Ultrasonic Open Channel Flowmeter With 4-20mA Output For Non-Contact Measurement And Installation

The ultrasonic open channel flowmeter is an instrument that uses ultrasonic principles to measure the liquid level height in open channels (such as drainage channels, rivers, and non-full pipes, etc.), and then combines standardized geometric dimensions and hydraulic models to calculate the fluid flow rate.

Main Features
  • Non-contact measurement: The sensor does not come into contact with sewage or corrosive liquids, is not affected by medium corrosion, foam or suspended solids, and has a long service life.
  • Easy installation: It only needs to be installed above the channel, does not affect the water flow, and there is no need to cut off the channel.
  • Low maintenance: There are no moving parts, and it is not prone to clogging.
  • Powerful functions: It can display instantaneous/cumulative flow, and has multiple signal outputs and communication interfaces.
Core components: Flowmeter + Weir
  • Ultrasonic Flowmeter Host (Secondary Instrument)
    • Ultrasonic probe: The core sensor, responsible for transmitting and receiving sound waves.
    • Host/Transmitter: Processes time signals, calculates the liquid level, and converts the liquid level into instantaneous flow and cumulative flow based on the built-in mathematical model (formula). It usually comes with display, data storage, and output functions (4-20mA, RS485, relay, etc.).
  • Standard Weir (Primary Component)

    This is the foundation of the entire measurement, its role is to form a stable water level-flow relationship at a specific location. Common types include:

    • Parshall Flume: The most commonly used type, with a constricted throat that can create a backwater effect, strong sediment passing capacity, and low head loss.
      • Features: It has standard sizes such as BS, LH, SH types, etc., and each size corresponds to a fixed empirical formula.
    • Triangular Weir/Rectangular Weir (Weir): Install a baffle with a notch (triangular or rectangular) in the channel.
      • Features: High measurement accuracy, but large head loss and prone to accumulation of debris.
    • Submersible: Suitable for non-full flow conditions where the water flow fills the pipe or culvert.

Key point: The ultrasonic flowmeter itself does not generate the flow formula; it only measures the liquid level and then uses the corresponding weir formula to calculate the flow. Selecting the wrong weir type or inputting incorrect weir dimensions will result in completely incorrect measurement results.

Selection Guide
  • Determine channel conditions: flow range, channel shape and size, water quality (whether it contains a large amount of floating debris and sediment).
  • Select weir type: Choose between Parshall flume, triangular weir, etc. based on flow range, accuracy requirements and allowable head loss.
  • Select instrument range: Determine the measurement blind zone and range of the instrument based on channel depth and maximum water level.
  • Output and communication: Select 4-20mA, pulse output or RS485/MODBUS and other communication protocols based on requirements.
Installation Specifications
  • Weir Channel Installation:
  • Must be installed horizontally. There should be sufficient straight channel sections upstream and downstream (typically 5-10 times the channel width upstream and 3-5 times the channel width downstream) to ensure smooth water flow.
  • Flowmeter Installation:
    1. Should be installed directly above the maximum water level of the weir channel.
    2. The probe face should be perpendicular to the water surface.
    3. Avoid the turbulent areas near the inlet and outlet of the weir channel.
    4. Ensure that the distance between the probe and the water surface is greater than the blind zone of the instrument at the highest water level (e.g., 0.3m to 0.5m).
    5. For larger channels, it is recommended to use a fixed bracket to prevent shaking.
Common Faults and Troubleshooting
Fault Phenomenon Possible Causes Troubleshooting Methods
No display or abnormal display Power failure, host damage Check power supply voltage and lines
Constant liquid level value or display of "?" Loss of signal, obstacles, foam or steam between probe and water surface Clean the probe, improve the environment, check the installation height
Large deviation in flow measurement value 1. Incorrect parameter settings (most common) 1. Verify weir or flume type and size
  2. Probe installation not level 2. Re-level the probe
  3. Weir or flume siltation or deformation 3. Clean and repair the weir or flume
  4. Inaccurate liquid level calibration 4. Re-calibrate the liquid level
Data fluctuates violently Strong water surface waves, wind interference Increase the damping coefficient of the instrument, install a flow stabilizing plate

Summary: The ultrasonic open channel flowmeter is a system that combines both hardware and software. Its accuracy is half dependent on the quality and installation of the hardware (the meter and standard flume), and the other half on the correctness of the software (the internal parameter settings of the meter). Correct selection, standardized installation and regular maintenance are the keys to ensuring its long-term stable operation.