Home ProductsOrifice Plate Flowmeter

High Accuracy Venturi Flowmeter Low Pressure Loss Wear Resistant

High Accuracy Venturi Flowmeter Low Pressure Loss Wear Resistant

  • High Accuracy Venturi Flowmeter Low Pressure Loss Wear Resistant
  • High Accuracy Venturi Flowmeter Low Pressure Loss Wear Resistant
  • High Accuracy Venturi Flowmeter Low Pressure Loss Wear Resistant
  • High Accuracy Venturi Flowmeter Low Pressure Loss Wear Resistant
High Accuracy Venturi Flowmeter Low Pressure Loss Wear Resistant
Product Details:
Place of Origin: China
Brand Name: QINWEIYB
Model Number: QWLU-GB105
Payment & Shipping Terms:
Minimum Order Quantity: 1Set
Price: Negotiable
Packaging Details: Carton
Delivery Time: 5-8 work days
Payment Terms: Western Union,T/T,D/P,D/A,L/C
Supply Ability: 100PCS/Month
Contact Now
Detailed Product Description
Name: Venturi Flowmeter Applicable Fluids: Liquids, Gases, Steam
Nominaldiameter Range: DN15 To DN600 Material: Stainless Steel
Pressurerating: ANSI Class 150 To 600 Connection Type: Flanged
Product Name: Orifice Plate Flowmeter Installation Type: Inline
Maintenance Requirement: Low Measurement Principle: Differential Pressure
Response Time: Instantaneous
Highlight:

High Accuracy Venturi Flowmeter

,

Venturi Tube Flow Meter Wear Resistant

,

Venturi Type Flow Meter Wear Resistant

Venturi Flowmeter With Extremely Low Pressure Loss High Accuracy And Wear-Resistant

The Venturi flowmeter is a differential pressure flow measurement instrument based on fluid dynamics principles. It calculates the flow rate by measuring the pressure difference generated when the fluid flows through the Venturi tube.

Classification and Structure
  • Classic Venturi Tube: Suitable for clean liquids/gases, with low pressure loss and low requirements for straight pipe sections (5D before and 2D after).
  • Tubular Venturi Tube: Specifically designed for high-pressure or hazardous media (such as natural gas), featuring a double-layer structure to prevent leakage.
  • Venturi Nozzle: With a shorter installation length, it is suitable for space-constrained scenarios.
Outstanding Features and Advantages

The advantages of the Venturi flowmeter almost all stem from its streamlined geometric structure:

  1. Extremely low permanent pressure loss
    • This is its core advantage. Compared with instruments that cause sudden throttling such as orifice plates and wedge flowmeters, the pressure recovery efficiency of the Venturi tube is very high, typically reaching 85% - 90%. This means that the energy consumption of the pump used to overcome the resistance of the flowmeter is extremely low, resulting in significant energy-saving effects over long-term operation.
  2. High accuracy and good repeatability
    • Accuracy can reach ±0.5% to ±1.0%.
    • Due to its streamlined design which causes minimal disturbance to the fluid, the flow coefficient is very stable and has good repeatability.
  3. Wear-resistant and dirt-tolerant
    • The smooth profile without sharp edges or stagnation zones makes it very suitable for measuring liquids containing small amounts of solid particles (such as circulating water, raw water), as particles are less likely to wear the throttling element or get stuck.
    • Compared to orifice plates, it is less sensitive to suspended solids upstream.
  4. Wide rangeability
    • The rangeability is typically 10:1, which is better than that of orifice plates.
  5. Relatively low requirement for upstream straight pipe sections
    • Due to its streamlined design which shapes the fluid, it is less sensitive to the upstream flow conditions than orifice plates. Typically, the upstream straight pipe section requirement is 5-10D.
Summary: Positioning of Venturi Flowmeters in the Differential Pressure Family
Characteristics Venturi Flowmeter Orifice Plate Flowmeter V-cone Flowmeter
Core Advantages Extremely low pressure loss (energy-saving) Simple structure, low cost High accuracy, wide range, strong flow straightening ability
Accuracy High (±0.5% ~ ±1.0%) Medium (±1.0% ~ ±2.0%) High (±0.5% ~ ±1.0%)
Permanent Pressure Loss Very low High Low
Cost Very high Very low High
Anti-clogging Ability Good Poor Good
Applicable Media Clean to moderately dirty Clean Clean to dirty
Common Types

According to different manufacturing methods, Venturi tubes are mainly classified as follows:

  1. Classic Venturi Tube:
    • Cast Contraction Section: The inlet section is cast, and the throat is machined.
    • Machined Contraction Section: Both the inlet section and the throat are precisely machined, offering the highest accuracy but also the highest cost.
    • Rough Welded Iron Plate Contraction Section: Used in large-diameter and low-precision requirements scenarios, such as water conservancy projects.
  2. Venturi Nozzle:
    • A standard ISA 1932 nozzle is installed at the inlet of the classic Venturi tube. Its performance lies between that of orifice plates and classic Venturi tubes, and it is shorter in length.
Typical Applications
  • Industrial fields: Petrochemical (raw material/fuel measurement), power (cooling water monitoring), metallurgy (coke oven gas measurement).
  • Environmental protection and water treatment: Wastewater flow monitoring, gas emission control (such as CO₂, NOₓ).
  • Special working conditions: Low-temperature media (liquid nitrogen, liquid oxygen), high-pressure steam (temperature resistance up to 530℃, pressure resistance up to 40MPa).

Conclusion: The Venturi flowmeter is the "high-performance sports car" among differential pressure flowmeters. Through its precise streamlined design, it sacrifices a high initial investment to achieve extremely low operating energy consumption and outstanding long-term measurement performance. In scenarios with large flow rates, continuous operation, and high pumping energy consumption, choosing a Venturi flowmeter is often a wise long-term investment.

Contact Details
Xi 'an Qinwei Instrument Factory (General Partnership Enterprise)

Contact Person: Mr. Wang

Tel: 19502991120

Send your inquiry directly to us (0 / 3000)