High Pressure Helical Gear Flowmeter 40 MPa Hydraulic Test Bench for Oil Leak Testing

Brand Name: QINWEIYB
Model Number: QW-HGF06P
Place of Origin: China
Certification: ISO 9001:2015, CE, PED 2014/68/EU
Minimum Order Quantity: 1 Set
Price: USD 560 - 1,480 / Set
Supply Ability: 600 Sets per Month

Product Details


Nominal Size: DN6 - DN25 Flow Range: 0.05 - 100 L/min
Max Working Pressure: 40 MPa Continuous, 50 MPa Peak Accuracy: ±0.5% Of Reading
Repeatability: ±0.1% Viscosity Range: 1 - 5000 CSt
Medium Temperature: -20 To 120 C Wetted Material: Hardened Tool-steel Rotor Set, Stainless Steel 1.4571 Chamber
Process Connection: G1/2, SAE-8 Or High-pressure Flange Output Signal: Pulse, 4-20 MA, RS485 Modbus RTU
Filtration Required: 10 Um Absolute Upstream
Highlight

High Pressure Helical Gear Flowmeter

,

Hydraulic Test Bench Leak Meter

,

40 MPa Oil Volumetric Measurement

Product Description

High Pressure Helical Gear Flowmeter for Hydraulic Test Benches and Leak Testing

Designed for test stands where a component is judged good or bad by a few millilitres of oil per minute at 40 MPa. The meter measures true displaced volume, holds its calibration from cold oil to hot oil, and gives a pulse output your PLC can totalise without a viscosity correction table.

High pressure helical gear flowmeter 40 MPa with heavy duty flange connections

High pressure helical gear flowmeter, 40 MPa body with heavy duty flanges.

Compact high pressure helical gear flowmeter for hydraulic test bench leak measurement

Second view: compact measuring chamber sized for leak flows from 0.05 L/min.

Why Test Benches Cannot Live With an Inferred Reading

A hydraulic test bench asks one question repeatedly: did this valve, pump or cylinder leak more than the limit? At 35 MPa the pass band is often 0.05–0.5 L/min against a background of oil that changes temperature by 40 °C during a shift. Any instrument that infers flow from rotor speed or pressure differential will drift across that band, and the drift becomes false rejects, retested parts and arguments with production.

Turbine meters are the usual first choice and the usual first failure: bearing drag rises as oil viscosity climbs at low temperature, so the K factor learned during a summer acceptance run no longer matches a winter morning. Differentials across an orifice plate flowmeter suffer the opposite problem, because viscosity changes the discharge coefficient itself. Neither instrument tells the operator whether the bench or the part is out of tolerance.

A helical gear meter counts displaced volume. The volume trapped between the helical rotors and the chamber wall is fixed by geometry, so the same pulse count corresponds to the same millilitres at 20 °C and at 70 °C. What changes with viscosity is the pressure needed to turn the gears, not the measurement — and on a bench that runs at 40 MPa, pressure is the one thing already available in abundance.

Two Working Conditions, Measured Side by Side

Comparison Item Condition A: Leak test at high pressure
(0.05–2 L/min, 35 MPa, oil at 25–45 °C)
Condition B: Endurance and flush cycle
(5–60 L/min, 25 MPa, oil at 65 °C)
Meter usually installedTurbine meter sized for the flush rateSame turbine meter, run at the low end of its range
Typical observed error±2% to ±4% drift with oil temperatureBearing wear after 6–9 months, K factor drifts up to 1.5%
Cost consequence3–6% false rejects on a good production batchUnplanned bench stop every quarter, rework of accepted parts
Repeatability actually achieved±0.8% short term, not stable across shifts±0.5% until wear sets in
Our configurationDN6 helical gear meter, 40 MPa, carbide bearings, 10 µm filtrationDN20 helical gear meter, 50 MPa peak rating, hardened rotors, RS485 to test software
Result on siteRepeatability ±0.1%, false rejects down 70%Two years running without accuracy drift beyond 0.2%

How Helical Gear Metering Holds Accuracy at Low Flow and High Pressure

Two helical rotors mesh inside a precision chamber. Product pressure turns them; the meshing line seals inlet from outlet, so a known volume is carried around the chamber wall on every rotation. Because the rotors are helical rather than straight-cut, the transfer of volume is continuous and gradual: there is no sudden opening and closing of a pocket, which is what produces the low pulsation and low noise this design is known for on a bench where a pressure gauge is being watched.

Each rotation generates a fixed number of pulses from a non-contact pick-up, and the K factor in pulses per litre is established on a gravimetric calibration rig at five points including the low-flow end where leak tests actually run. At 0.05 L/min the meter is turning slowly but still turning, and the trapped volume per revolution never changes — which is why the turndown reaches 1:200 without a technology change.

Pressure handling comes from the housing and the bearings, not from the measuring principle. The chamber wall is thick-sectioned and the rotor pins run in tungsten carbide bushes, so 40 MPa continuous and 50 MPa peak do not distort the measuring gap. A small internal leakage across the meshing line does exist and rises with differential pressure; it is characterised on the certificate, so the leak-test software can subtract it or work against a corrected curve.

Structural Design for Pressure Spikes, Contamination and Continuous Duty

Test benches are hostile in three specific ways, and the mechanical design answers each one:

  • Pressure spikes and relief-valve events. A thick-walled chamber, bolted end plates with metal-to-metal seals and a 50 MPa peak rating keep the measuring gap stable when a directional valve closes abruptly.
  • Contaminated oil. Hardened tool-steel rotors and tungsten carbide bearing pins tolerate the occasional particle that a stainless-on-stainless design would score. We specify 10 µm absolute filtration upstream and most benches already provide it for the component under test.
  • Continuous three-shift duty. The rotor set and bearings are supplied as a matched pair, so wear is corrected on site by replacing the pair and recalibrating, rather than scrapping the whole instrument.

Six Advantages on a Test Bench

AdvantageWhy it matters to the buyer
40 MPa continuous, 50 MPa peakInstalls directly in the high-pressure line; no bypass loop, no pressure reducer that adds its own error.
Helical rotor pair, low pulsationPressure traces stay clean during measurement, so the operator can distinguish meter noise from component behaviour.
1:200 turndownOne meter covers 0.05 L/min leak measurement and 100 L/min flush without a second instrument or a range change.
Hardened rotors with carbide bearingsSurvives the fines that escape filtration and the pressure transients of valve closing.
Integrated temperature sensor and three outputsPulse for totalising, 4–20 mA for the trend recorder, RS485 Modbus RTU straight into the test software.
Matched-pair service kitWear is repaired on site with gears and bearings, then recalibrated — no return shipment, no four-week bench outage.

Selection, Filtration and Calibration for Bench Integration

Start from the smallest flow you must resolve. For leak detection at 0.05–2 L/min choose DN6; for a dyno rig running 5–80 L/min choose DN20. If a single bench must do both, install the small meter on the leak branch and the larger one on the return line — see the rest of our positive displacement range for the sizes in between — two instruments cost less than the rejects caused by stretching one meter across a 1:2000 range.

Mounting is simple because there is no straight-run requirement: the meter can sit on the manifold block, upstream of the test coupling, with elbows on both sides. Two rules apply. Keep the flow arrow aligned with actual flow, and for horizontal installation keep the rotor shaft axis horizontal so air cannot be trapped after an oil change. For benches that flush in both directions, order the bi-directional version with dual pulse output.

Calibrate with ISO VG 46 mineral oil at 40 °C on a gravimetric rig, record five points, and publish a viscosity correction curve for the operating range so the PLC can compensate if the bench runs cold or hot. If the bench tests fluids other than mineral oil, we calibrate with your fluid instead — the K factor is a property of geometry, not of marketing claims.

High pressure helical gear flowmeter integrated on a hydraulic test bench

Integration layout (schematic drawing): leak measurement and full-flow flush on one meter.

Application Case 1: Hydraulic Valve Manufacturer, Italy

Customer profileDirectional and proportional valve manufacturer, two plants
Country / regionItaly, Emilia-Romagna
IndustryHydraulic components
ApplicationEnd-of-line leak test bench, internal leakage measured on every valve
MediumISO VG 46 mineral oil, 25–65 °C over a shift
Flow range0.05–2 L/min leak measurement, 60 L/min flush
Accuracy requirement±0.5% of reading, repeatability 0.1%
ChallengeTurbine meter unstable at leak flows; temperature drift produced 4–6% false rejects and manual retesting
Our configurationQW-HGF06P, DN6, 40 MPa, hardened tool-steel rotors, carbide bearings, 10 µm filter upstream, pulse + 4–20 mA into the bench PLC
ResultRepeatability ±0.1% confirmed across the full oil temperature range, false rejects down about 70%, bench now runs unattended overnight

Application Case 2: Hydraulic Component Remanufacturer, Chile

Customer profileRemanufacturer serving mining and construction fleets
Country / regionChile, Antofagasta region
IndustryHydraulic pumps and motors, remanufacturing
ApplicationDyno endurance rig, acceptance run after rebuild
MediumHVLP 46 hydraulic oil, 60 °C, 25 MPa working pressure
Flow range5–80 L/min, continuous three-shift duty
Accuracy requirement±0.5% of reading for efficiency calculation, stable over 12 months
ChallengePressure spikes to 48 MPa during relief tests, fine dust in the workshop, previous turbine meter replaced every 8 months
Our configurationQW-HGF20P, DN20, 50 MPa peak rating, hardened rotors, IP65 DIN connector, RS485 Modbus RTU to the dyno software
ResultTwo years of operation with no accuracy drift beyond 0.2%, one matched-pair service kit in stock instead of a spare instrument

Technical Specifications

ParameterValue
Nominal sizeDN6 – DN25
Flow range0.05 – 100 L/min
Max. working pressure40 MPa continuous, 50 MPa peak
Accuracy±0.5% of reading
Repeatability±0.1%
Viscosity range1 – 5,000 cSt
Medium temperature−20 °C to 120 °C
Wetted materialHardened tool-steel rotor set, chamber in stainless steel 1.4571
Process connectionG1/2, SAE-8 or high-pressure flange to drawing
Output / protectionPulse, 4–20 mA, RS485 Modbus RTU; IP65

Frequently Asked Questions

Why not use a turbine or a Coriolis meter on a hydraulic test bench?

A turbine meter relies on bearing-supported blades that slow down as oil viscosity rises with temperature, so a cold start at 20 °C and a warm run at 65 °C give different K factors unless you correct continuously. On a leak bench where the pass criterion is often a few millilitres per minute, that drift can be larger than the leak being measured. Coriolis meters are accurate and measure mass directly, but the smallest units cost several times more, are sensitive to pump pulsation, and are over-specified for routine pass/fail testing. A helical gear meter holds volumetric accuracy across the viscosity range, accepts 40 MPa working pressure, and produces a pulse output the PLC totalises without any conversion layer.

How does oil contamination affect accuracy and service life?

Hard particles are the main life limiter. Gears and bearings run with clearances measured in micrometres, so a 50 µm particle can score a rotor face and change the trapped volume permanently. Bench pressure is normally logged by a pressure transmitter on the same manifold, and the two channels should be calibrated against the same reference. We specify 10 µm absolute filtration upstream, which most test benches already provide for the component under test. Our rotor set uses hardened tool steel with tungsten carbide bearing pins, which tolerates occasional fines far better than stainless-on-stainless designs. When accuracy drifts more than 0.3% against your reference, the gear pair and bearings are replaced as a matched set on site and the meter is recalibrated — the housing and sensor stay in service, so the repair takes hours, not weeks.

Can the meter be mounted directly on the test bench manifold?

Yes, and that is how most of our customers install it. Because the measuring principle counts trapped volumes rather than inferring velocity, no upstream or downstream straight run is required, so the meter can sit close to a manifold block, a quick-release coupling or a directional valve. Two conditions apply: keep the flow direction arrow aligned with actual flow, and for horizontal mounting keep the rotor shaft axis horizontal so air cannot be trapped after an oil change. Where a bench flushes in both directions, order the bi-directional version with dual pulse output. Send us the manifold drawing before the order is released and we will confirm orientation, clearance and connection thread in writing.

What calibration fluid and conditions are used?

We calibrate with ISO VG 46 mineral oil at 40 °C unless your specification says otherwise, on a gravimetric rig with a traceable balance and temperature correction. Five points are recorded across the flow range, including the low-flow end where leak tests run. The certificate states the K factor in pulses per litre, the deviation at each point, and the ambient and fluid temperature during the test. Because viscosity and temperature shift the K factor slightly, we also publish a correction curve for your operating range so the PLC can compensate when the bench runs at 30 °C or 70 °C. Calibration with your own fluid is available when the bench handles fluids other than mineral oil.

Related Products and Further Reading

Test bench instrumentation is usually specified together, so these pages are the ones engineers ask for next:

Send us the manifold drawing and the leak limit you must resolve, and we will confirm size, connection and K factor in writing before the order is released.

Product Highlights

Helical gear flowmeter rated 40 MPa continuous for hydraulic test benches, ±0.5% accurate from 0.05 L/min leak flows to 100 L/min flush, hardened rotors with carbide bearings.

RELATED PRODUCTS
Quality Petroleum Radar Level Gauge 26GHz High Temperature Industrial factory

Petroleum Radar Level Gauge 26GHz High Temperature Industrial

Petroleum Radar Level Gauge brings 26GHz radar precision and high-temperature capability to oil storage tank measurement. Every millimeter of level is tracked accurately to prevent inventory loss and safety risk. Inquire now for specifications.

Quality Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor factory

Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor

Portable FMCW Radar Level Gauge brings laboratory-grade radar measurement to any tank in the plant or field. With IP67 protection and quick setup, it delivers accurate liquid level readings without permanent installation. Contact us for specifications.

Quality Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay factory

Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay

Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.

Quality Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement factory

Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement

Universal Gauge Pressure Transmitter measures pressure relative to the atmosphere for pump discharge, line pressure, tank head and filter differential applications. With 4-20mA output, it suits oil, water and gas measurement. Contact us for range options.

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.