Spool Piece Ultrasonic Flowmeter QWUS-SP2000 DN15-DN600 0.5% Accuracy for Chilled Water Metering

Brand Name: QINWEIYB
Model Number: QWUS-SP2000
Place of Origin: Shaanxi, China
Certification: ISO 9001:2015, CE
Minimum Order Quantity: 1 Set
Price: USD 380-2,600 / Set
Supply Ability: 100 Sets per Month

Product Details


Nominal Diameter: DN15-DN600 Accuracy: +/-0.5% Of Reading (0.3% Option)
Velocity Range: 0.05-12 M/s Bidirectional Straight Pipe Requirement: 5D Upstream, 3D Downstream
Fluid Temperature: -20 To +120 C (160 C Optional) Nominal Pressure: PN16 Standard, PN25/PN40/Class150/Class300 Optional
Body Material: Carbon Steel Epoxy Coated, Stainless Steel Optional Protection Class: IP68 Measuring Section
Outputs: 4-20mA, Pulse, RS485 Modbus RTU, HART Optional Power Supply: 85-265 VAC Or 24 VDC, <5W
Highlight

Spool Piece Ultrasonic Flowmeter

,

0.5% Accuracy Chilled Water Metering

,

Factory Calibrated Flanged Spool Body

Product Description

Spool Piece Ultrasonic Flowmeter for Chilled Water and Closed-Loop HVAC Metering
When a chilled water header, a district heating substation or a plant cooling loop needs a meter that will still read true after fifteen years of continuous duty, the deciding factor is not the display — it is whether anything inside the pipe can wear out. The QWUS-SP2000 answers that with a flanged spool body and two transducers coupled into the pipe wall, measuring transit time across the water column instead of spinning a rotor.
Why Plant Engineers Replace Mechanical Meters on Chilled Water Loops

Flow measurement problems in closed loops rarely arrive as a bang. They arrive as drift. The energy billing figure stops reconciling with the chiller log, the BMS trend turns jagged at night when pumps run at 40 %, and eventually someone cuts the pipe open to find a turbine rotor scuffed flat by grit that has been circulating since the first flush. By then the site has already paid twice: once for a meter that under-read, and once for the commercial dispute the under-reading created.

Three patterns push a buyer from mechanical toward transit-time ultrasonic measurement:

  • Load swings are wide. Variable-speed pumps have pushed closed loops from a constant 2 m/s design point down to 0.3 m/s for most of the night. A turbine that is accurate at design flow can lose most of its usable turndown below 15 % of range.
  • The water is not clean. Glycol top-ups, magnetite from old steel pipe and construction debris all attack bearings. Every maintenance intervention on a mechanical meter means a shutdown, a gasket set and a re-commissioning record.
  • Pressure budget is spent elsewhere. In a loop already tight on differential head, a meter that costs 10–30 kPa of permanent pressure loss is a meter that forces a larger pump.
Two Operating Conditions That Break a Mechanical Meter
Service conditionWhat the site normally seesCommercial consequenceHow the spool ultrasonic meter responds
Night / low-load operation
0.3–0.8 m/s, single pump running, long idle periods
Mechanical meter drops below its start-up flow and reads zero while the chiller clearly consumes energy; totalising error accumulates silently across six months of night shifts Energy invoices under-recover by 8–15 %; tenant disputes surface at year-end reconciliation with no way to reconstruct the missing data Bidirectional transit-time measurement holds 1 %–2 % of reading down to 0.05 m/s, so night flow is fully captured; no start-up threshold to cross
Fouled or glycol-charged water
20–35 % propylene glycol, magnetite and biofilm on pipe wall
Wear on rotor and bearings accelerates, reading drifts 5–10 %, and sediment traps in the body causing a progressive drop in indicated flow Unplanned shutdown to swap the meter, loss of contractual accuracy, and a cooling season on suspect data before the fault is confirmed No moving parts and no obstruction in the bore; transducer pockets sit flush, so solids pass through and wall fouling is compensated by the documented roughness setting
How Transit-Time Measurement Works Inside a Spool Body

The measurement has nothing to do with the mass of the water and everything to do with the sound velocity of it. Two piezoelectric transducers sit in the spool at a known angle and a known path length apart. Each fires an acoustic pulse through the water. A pulse travelling with the flow arrives marginally sooner than a pulse travelling against it, and the resulting time difference is proportional to the average velocity along the acoustic path.

That single physical relationship is what makes the device so durable in service:

  • Velocity is derived from time, not from motion. There is no rotor to stall, no bearing to clog and no reed switch to fatigue — the sensor only has to survive, not to move.
  • Density, pressure and viscosity do not enter the calculation. A glycol concentration change alters the sound speed and is corrected internally, so the volumetric reading stays inside specification across the season.
  • Multi-path averaging flattens the profile. The SP2000 uses a reflected double-path arrangement that averages across the diameter, which is why a compact upstream run of 5 D is sufficient instead of the 10–20 D demanded by insertion probes.
  • Reverse flow is measured, not ignored. Both directions are counted with sign, so a circulating loop that reverses during valve changeover does not lose volume or corrupt the total.

Inside the spool the acoustic path sits in a machined seat with a defined path length and angle, and that is the decisive difference from clamp-on hardware: the geometry is fixed at the factory rather than established by a field installer with a tape measure. Consequently the stated 0.5 % of reading applies to the meter as it leaves the workshop, with no site-dependent derating.

Structural Advantages of an Integral Flanged Spool Piece

Buyers who compare a spool body with a clamp-on set are usually weighing install effort against purchase price. The honest engineering answer is that the spool pays back in the first commissioning window, because it removes the widest source of error in ultrasonic flow measurement: variable transducer geometry.

1. Factory-fixed acoustic geometryThe transducer pockets are machined at the calculated angle and path length for the ordered line size, then wet-calibrated against a gravimetric or master-meter rig. Accuracy is a property of the instrument, not of the installation technique.
2. Zero obstruction in the boreThe measuring section is a straight tube with flush-mounted transducers, so permanent pressure loss is negligible and the same spool can serve slotted debris in a cooling tower circuit without a strainer upgrade.
3. Short straight-run requirementDouble-path reflection averaging allows 5 D upstream and 3 D downstream, which is what makes a spool workable in a plant room where a 20 D clamp-on station simply does not exist.
4. Sealed IP68 measuring sectionThe spool and cable entry are potted for IP68, so a flooded trench, a wash-down bay or a buried meter chamber does not become a warranty conversation.
5. Converter mounted where people can read itIntegral or remote converter options let the display sit at eye level on a plant-room wall while the spool stays in the pipe, and the RS485/Modbus module feeds the BMS directly without an additional transmitter.
6. Energy metering without extra hardwareWith matched PT100 pairs on flow and return, the same converter computes thermal energy in kWh from flow and ΔT, replacing a separate heat meter on substation and chiller billing points.
Where the Spool Meter Fits and How to Size It

Typical duty covers chilled and hot water in commercial buildings, district heating substations, boiler feed and make-up lines, process cooling water and CIP circuits. The sizing rule that keeps accuracy predictable is to land the design flow between 1.0 and 3.0 m/s so the night-time turn-down still sits above 0.1 m/s, and to step down one line size rather than accept a meter running permanently in the bottom fifth of its range.

Field Case 1 — District Cooling Substation, United Arab Emirates
IndustryDistrict cooling / facility management
Site and regionTwo-tower commercial complex, Dubai, UAE
Application pointPrimary chilled water supply to each tower's energy transfer station
Fluid and temperatureChilled water with 25 % propylene glycol, 4–12 °C
Line size and flow rangeDN200 flanged spool, 30–420 m³/h
Measurement challengeNight flow fell to 6 % of design; the existing turbine read zero for roughly nine hours per day and the tenant billing split could not be defended
Configuration suppliedQWUS-SP2000, DN200, PN16 flanged, integral converter, RS485 Modbus to BMS, paired PT100 inputs
Accuracy achieved±0.5 % of reading verified on site by portable clamp-on comparison at three load points
Commissioning timeFour hours, one shutdown window, no pipe modification beyond flange alignment
Verified resultRecovered night-time volume lifted metered consumption by 11 % in the first quarter, matching the chiller energy log within 2 %
Field Case 2 — Automotive Plant Cooling Loop, Nuevo León, Mexico
IndustryAutomotive parts manufacturing
Site and regionStamping and welding plant, Monterrey, Mexico
Application pointClosed cooling water loop serving welding transformer skids, three parallel branches
Fluid and temperatureDemineralised cooling water with corrosion inhibitor, 28–38 °C
Line size and flow rangeDN80 flanged spool, 8–95 m³/h per branch
Measurement challengeOnly 6 D of straight pipe available between elbow and header; clamp-on trials produced 8–12 % scatter between units
Configuration suppliedQWUS-SP2000, DN80, PN25, compact integral converter, 4–20 mA plus pulse output to plant historian
Accuracy achieved±0.5 % of reading, repeatability ±0.15 % across five repeat runs
Commissioning timeSix hours for three spools during a scheduled maintenance day
Verified resultBranch imbalance traced to a partly closed isolation valve; balancing cut pump energy by 7 % and ended the recurring high-temperature alarms
Technical Specifications
Nominal diameterDN15 – DN600 (flanged spool standard; larger on request)
Accuracy±0.5 % of reading standard; ±0.3 % option with factory multi-point calibration
Repeatability±0.15 % of reading
Velocity range0.05 – 12 m/s, bidirectional, turndown better than 200:1
Fluid temperature−20 °C to +120 °C (high-temperature transducer set to +160 °C optional)
Nominal pressurePN16 standard; PN25 / PN40 / Class 150 / Class 300 on request
Straight pipe requirement5 D upstream, 3 D downstream
Body and liningCarbon steel body with epoxy coating; stainless steel option; potted IP68 measuring section
Outputs4–20 mA, pulse, RS485 Modbus RTU, HART optional, two PT100 inputs for energy calculation
Power supply and display85–265 VAC or 24 VDC, <5 W; backlit LCD showing flow, total, velocity and diagnostics
Frequently Asked Questions
Does a spool piece ultrasonic flowmeter need a long straight pipe run?

It needs far less than most engineers expect. The SP2000 uses a reflected double-path acoustic arrangement that averages the velocity profile across the diameter, so 5 D upstream and 3 D downstream are sufficient for the published accuracy. That matters in plant rooms and substations where a clamp-on station would need 10–20 D and simply has no wall length to offer. Where an elbow sits immediately upstream, a flow conditioner or one additional pipe diameter restores confidence. If your layout is tighter than 5 D, send the isometric drawing with the enquiry and we will confirm whether a dual-plane configuration or a different line size is the better answer.

How does the meter cope with glycol, fouling and old steel pipe?

Glycol changes the speed of sound in the water, and the converter corrects for it once the concentration is entered, so volumetric accuracy holds across the season. Wall roughness from magnetite or biofilm is handled through the documented roughness setting rather than by assumption, which keeps a fouled DN200 line inside roughly 1 % of reading instead of drifting two or three times that. Because the bore is unobstructed, debris passes through and the transducer faces are flush with the pipe wall, so there is nothing to catch solids. For heavily fouled loops we recommend a periodic ultrasonic wall-thickness check and a recalibration interval of two years instead of the usual three.

Can the same meter produce an energy figure for billing?

Yes, provided matched temperature sensors are ordered with it. The converter accepts two PT100 inputs, one on the supply and one on the return, and computes thermal energy in kWh by integrating flow against the temperature difference. Accuracy of the energy figure then depends mainly on the sensor matching rather than on the flow element, which is why we supply paired sensors calibrated as a set. This removes a separate heat meter from the substation bill of materials and, more importantly, removes the reconciliation mismatch that appears when flow and temperature come from two different devices with two different clocks and two different accuracy statements.

What is the realistic delivery and commissioning sequence?

Standard flanged sizes in PN16 with an integral converter ship from stock in five to eight working days; PN25 and above, stainless bodies and the ±0.3 % calibration option add two to three weeks. Commissioning is a single shutdown: isolate the section, drop the spool between the flanges, torque to the drawing values, power up and confirm zero flow with the section filled and pumps stopped. Menu setup takes about twenty minutes for line size, units and output scaling. We supply a commissioning sheet with the meter so the zero check and the first flow verification are recorded in a form your QA file can accept without a follow-up visit from a service engineer.

Send us your line size, flow range and fluid temperature

We will return a sized spool drawing, flange standard confirmation and a quotation within one working day.

Product Highlights

Spool piece ultrasonic flowmeter for DN15-DN600 chilled water and closed-loop HVAC metering. Factory-calibrated double-path transit-time measurement holds 0.5% of reading down to 0.05 m/s, with no moving parts, 5D straight-run requirement and optional PT100 energy calculation. Send your line size and flow range for a sized quotation.

RELATED PRODUCTS
Quality Petroleum Radar Level Gauge 26GHz High Temperature Industrial factory

Petroleum Radar Level Gauge 26GHz High Temperature Industrial

Petroleum Radar Level Gauge brings 26GHz radar precision and high-temperature capability to oil storage tank measurement. Every millimeter of level is tracked accurately to prevent inventory loss and safety risk. Inquire now for specifications.

Quality Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor factory

Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor

Portable FMCW Radar Level Gauge brings laboratory-grade radar measurement to any tank in the plant or field. With IP67 protection and quick setup, it delivers accurate liquid level readings without permanent installation. Contact us for specifications.

Quality Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay factory

Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay

Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.

Quality Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement factory

Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement

Universal Gauge Pressure Transmitter measures pressure relative to the atmosphere for pump discharge, line pressure, tank head and filter differential applications. With 4-20mA output, it suits oil, water and gas measurement. Contact us for range options.

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.