Quality Ultrasonic Open Channel Flowmeter QWUS-OC3000 Weir Flume Effluent Discharge Compliance Monitoring factory
<
Quality Ultrasonic Open Channel Flowmeter QWUS-OC3000 Weir Flume Effluent Discharge Compliance Monitoring factory
Quality Ultrasonic Open Channel Flowmeter QWUS-OC3000 Weir Flume Effluent Discharge Compliance Monitoring factory
Quality Ultrasonic Open Channel Flowmeter QWUS-OC3000 Weir Flume Effluent Discharge Compliance Monitoring factory
Quality Ultrasonic Open Channel Flowmeter QWUS-OC3000 Weir Flume Effluent Discharge Compliance Monitoring factory
>

Ultrasonic Open Channel Flowmeter QWUS-OC3000 Weir Flume Effluent Discharge Compliance Monitoring

Brand Name: QINWEIYB
Model Number: QWUS-OC3000
Place of Origin: Shaanxi, China
Certification: ISO 9001:2015, CE
Minimum Order Quantity: 1 Set
Price: USD 380-2,600 / Set
Supply Ability: 100 Sets per Month

Product Details


Channel Width Range: 0.3-10 M Level Measurement: Non-contact Ultrasonic, 0-3 M, 1 Mm Resolution
Velocity Measurement: Doppler Sensor, 0.02-6 M/s Bidirectional Accuracy: +/-1% Of Reading With Weir Or Flume, 2-5% Area-velocity
Supported Structures: V-notch And Rectangular Weirs, Parshall, Palmer-Bowlus, Cut-throat Flumes Fluid Temperature: 0-60 C
Enclosure Protection: Sensor IP67, Converter IP65 Data Logging: Two Years At 15-minute Intervals, CSV Export
Outputs And Telemetry: 4-20mA, Pulse, Relay, RS485 Modbus RTU, GPRS/NB-IoT Optional Power Supply: 85-265 VAC, 12 VDC Or Solar With Battery
Highlight

Ultrasonic Open Channel Flowmeter

,

Weir Flume Discharge Measurement

,

Non-Contact Level and Velocity Sensing

Product Description

Ultrasonic Open Channel Flowmeter for Weir, Flume and Effluent Discharge Compliance
A discharge consent, an abstraction licence or an irrigation allocation is written in cubic metres per day, but the channel on site is an open trench with silt on the bottom and a level that moves with the weather. The QWUS-OC3000 sits above that channel, measures water level continuously, converts it into discharge through a weir or flume, or through direct velocity sensing where no structure exists, and logs the figures your permit officer will ask for.
Why Effluent Permits and Irrigation Allocations Demand Continuous Channel Data

Grab samples and staff gauge readings were adequate when the reporting cycle was annual. They are not adequate now. Regulators increasingly ask for daily or hourly discharge volume, and the same agencies compute load charges from those volumes. Meanwhile the practical problem at most sites is that an open channel has no pressure, no full pipe and no stable cross-section, so the instruments that work beautifully on a pressurised line — magnetic, turbine, positive displacement — have nothing to work with.

Four conditions define open channel duty, and all of them are common in plants that have already tried something else:

  • The flow is not full. A pipe running at half depth cannot be metered by any full-bore device; the wetted area changes with level, so level itself has to be a measured variable.
  • The instrument sits in a hostile place. Silt, rag, grit, algae and flood debris accumulate on anything submerged, and submersible sensors in raw sewage need cleaning on a schedule nobody has staff for.
  • Reporting is auditable. Monthly totals must be reconstructable from stored records, with the structure dimensions and the equation used, not inferred from a single visit.
  • Remote sites have no mains power. A headworks or a storm outfall often has to run on solar with telemetry, which rules out instruments that draw tens of watts continuously.
Two Channel Conditions Compared
Service conditionWhat the site normally seesCommercial consequenceHow the open channel meter responds
Structured channel
V-notch weir or Parshall flume, steady dry-weather flow, silt depositing upstream
Submerged level probes foul with silt and algae; floats jam; staff gauge readings are taken weekly and interpolated Discharge totals are reconstructed from a handful of readings, so load charges and consent compliance cannot be defended during an inspection Non-contact ultrasonic level referenced to the structure crest, logged every minute; silt below the beam has no effect on the reading
Unstructured channel
Earthen or concrete ditch, variable backwater, storm surges, no weir present
No hydraulic relationship exists, so a level-only device produces a number that is wrong at every depth above the calibration point Irrigation allocation is applied as a pro-rata estimate; storm overflow volumes go unrecorded while the receiving water impact is still chargeable Area-velocity mode measures depth and surface velocity together, computing discharge from the live cross-section instead of an assumed curve
How Level-Velocity Integration Converts Depth into Discharge

Discharge in an open channel is the product of wetted area and mean velocity, and neither term can be assumed when the channel is not full. The OC3000 solves the two halves of that equation in one instrument: an upward-looking ultrasonic transducer measures water level from the surface, and either a built-in hydraulic structure relationship or a Doppler velocity sensor supplies the second term.

  • Structured channel route. Once the weir or flume geometry is entered — crest width, notch angle, throat width, approach width — the converter applies the standard head-discharge equation for that structure. Level accuracy then dominates the result, which is why a non-contact sensor with millimetre resolution is the right front end.
  • Area-velocity route. Where no structure exists, a submerged or side-mounted Doppler sensor measures mean velocity near the bed, and the converter combines it with the wetted area computed from the measured level and the surveyed channel profile.
  • Zero and datum stability. The reference datum is set at commissioning and stored, so a sensor that is re-aimed after maintenance returns to the same datum instead of silently shifting the whole discharge curve.
  • Backwater and surcharge flags. If the level rises above the modular limit of the structure, submerged-flow correction is applied and the event is logged, so totals during a storm are marked rather than quietly wrong.

The accuracy statement follows from that logic. On a weir or flume in modular flow, ±1 % of reading is achievable because the hydraulic relationship is fixed and only the head has to be measured well. In area-velocity mode, expect ±2 % to ±5 % depending on how well the channel profile is surveyed and how uniform the velocity distribution is at the measuring section.

Non-Contact Structure That Survives Silt, Debris and Flood Stage

The single largest maintenance cost in open channel metering is not the instrument — it is the visits to clean it. A sensor that never enters the water removes that cost entirely, and it changes what the instrument can survive.

1. Nothing in the water, nothing to foulThe level transducer mounts 0.3–1.5 m above the surface on a bracket or bridge. Silt, rag, grease and algae cannot coat a sensor that is not immersed, so the cleaning interval moves from weeks to an annual inspection.
2. Unaffected by sediment build-upDeposited bed material changes the channel invert over time. Because level is measured from the surface, the reading is unaffected, and the profile can be re-surveyed and re-entered without touching the hardware.
3. Survives flood stage without damageA sealed IP67 housing above the high-water line is not exposed to debris impact or hydrostatic loading during a storm event, which is exactly when the data matters most and when submerged instruments are most often lost.
4. Battery and solar viableTypical draw is under 0.5 W in low-power logging mode, so a small panel and a 12 V battery carry a remote headworks through a monsoon season without a mains connection.
5. Logged records, not just a live numberTwo years of interval data at fifteen-minute resolution sits in internal memory with battery-backed retention, so a compliance query can be answered from the instrument rather than reconstructed from notebooks.
6. Telemetry and SCADA without extra hardwareRS485 Modbus, 4–20 mA and pulse outputs are standard, with GPRS or NB-IoT modules available for sites where the only option is a cellular link to the plant historian or the regulator's portal.
Choosing Between Weir, Flume and Area-Velocity Configurations

The structure decision usually comes before the instrument decision, and it should be driven by what the channel can physically accept. A V-notch weir gives the best low-flow resolution and is ideal for small effluent ditches, but it needs a stilling approach and it will be drowned by backwater. A Parshall or Palmer-Bowlus flume passes solids and tolerates a flatter gradient, at the cost of poor resolution at very low flow. Where the channel is earthen, irregular or already built with no head available, area-velocity sensing avoids civil work altogether. Measure the channel width, the maximum depth, the expected flow band and the available upstream straight length, and the correct answer usually becomes obvious.

Field Case 1 — Municipal Wastewater Effluent Consent, Lima, Peru
IndustryMunicipal wastewater treatment
Site and regionWastewater treatment plant, Lima, Peru
Application pointFinal effluent channel downstream of chlorination, discharging to a coastal outfall
Fluid and temperatureTreated municipal effluent, 1–2 % residual solids, 18–26 °C
Channel and flow rangeConcrete channel 1.2 m wide with existing Parshall flume, 180–2 400 m³/h
Measurement challengeSubmerged level probes had been cleaned weekly and still drifted; the consent required hourly discharge reporting that the plant could not produce
Configuration suppliedQWUS-OC3000 with non-contact level sensor, Parshall flume equation loaded, 4–20 mA to plant SCADA plus 15-minute internal logging
Accuracy achieved±1 % of reading in modular flow, verified against a portable reference during three flow conditions
Commissioning timeThree hours including datum setting and two-point verification; no channel modification
Verified resultHourly discharge records accepted at the first regulatory audit; probe cleaning eliminated from the maintenance schedule
Field Case 2 — Irrigation Canal Abstraction, Nile Delta, Egypt
IndustryAgricultural irrigation and water distribution
Site and regionIrrigation district headworks, Nile Delta, Egypt
Application pointSecondary canal offtake supplying approximately 600 hectares of farmland
Fluid and temperatureIrrigation water with fine silt, 15–32 °C
Channel and flow rangeTrapezoidal earthen channel, 2.6 m top width, depth 0.2–1.4 m, 0.15–3.4 m³/s
Measurement challengeNo weir or flume existed and no head was available to build one; no mains power at the offtake; allocation disputes with downstream users
Configuration suppliedQWUS-OC3000 area-velocity configuration, submerged Doppler velocity sensor, surveyed trapezoidal profile, solar panel with 12 V battery, GPRS telemetry
Accuracy achieved±3 % of reading after profile survey and current-meter cross-check at two depths
Commissioning timeOne day including channel cross-section survey, sensor mounting and telemetry link test
Verified resultDaily allocation volumes published from telemetry; the seasonal dispute was resolved with a shared record both parties accepted
Technical Specifications
Channel width range0.3 – 10 m (wider channels quoted individually)
Level measurementNon-contact ultrasonic, range 0 – 3 m, resolution 1 mm, beam angle 8°
Velocity measurementDoppler sensor, 0.02 – 6 m/s bidirectional (area-velocity configuration)
Accuracy±1 % of reading with weir or flume in modular flow; ±2–5 % in area-velocity mode
Supported structuresV-notch and rectangular weirs; Parshall, Palmer-Bowlus and cut-throat flumes; custom head-discharge table import
Fluid temperature0 – 60 °C (sensor rated −20 – 70 °C ambient)
Enclosure protectionSensor IP67; converter IP65 with lockable enclosure option for outdoor installation
Data loggingInternal memory for two years at 15-minute intervals, battery-backed, CSV export via USB
Outputs and telemetry4–20 mA, pulse, relay alarm, RS485 Modbus RTU; GPRS / NB-IoT module optional
Power supply85–265 VAC, 12 VDC or solar with battery; consumption below 0.5 W in logging mode
Frequently Asked Questions
Weir, flume or area-velocity — which configuration suits my channel?

Start from the civil constraint rather than from the instrument. If the channel is small, has reliable free fall and low flow must be resolved precisely, a V-notch weir is the strongest choice because head varies steeply with flow. If the water carries solids and the gradient is flat, a Parshall or Palmer-Bowlus flume passes debris and needs less head. If there is no structure, no available fall and no budget for civil work, area-velocity measurement avoids construction entirely and delivers ±2–5 % with a proper channel survey. Send channel width, maximum depth, expected flow band and a photograph of the site, and we will recommend one route and state the accuracy you can realistically expect from it.

Does silt, algae or flood debris affect a non-contact sensor?

Not in the way it affects submerged instruments. The level transducer looks down from above the water, so silt on the bed changes the channel invert but not the surface reading, and algae cannot grow on a dry sensor face. Debris passing underneath is only a problem if it is large enough to break the acoustic path for a sustained period, which is uncommon and self-clearing. The practical maintenance item is the sensor face itself: dust, cobwebs and bird droppings attenuate the beam, so a wipe during the annual inspection is usually enough. Diagnostics report echo strength continuously, so a degrading face shows up as a falling signal figure long before the flow record becomes unreliable.

Will the records stand up to a regulatory audit?

That depends on traceability rather than on the sensor alone. Every OC3000 shipment includes a configuration record listing the structure type, crest or throat dimensions, the equation applied and the datum used, and the instrument logs interval data with timestamps and backwater flags. Together those give an auditor a reconstructable trail from raw level to reported volume, which is the question that is actually asked during an inspection. Where a consent specifies a particular standard method, tell us which one at the enquiry stage and we will confirm whether the structure equation is supported. Periodic verification against a portable reference is recommended annually and forms part of the evidence pack.

Can it run on solar power at a remote site without mains electricity?

Yes. In low-power logging mode the instrument draws under 0.5 W, so a 20–40 W panel with a 12 V sealed battery carries a typical headworks or outfall through cloudy periods and keeps the logger running. The choice that affects battery life more than anything else is telemetry: continuous cellular links dominate consumption, so we normally configure scheduled uploads, for example every fifteen minutes with an event-triggered alert on level rise, instead of a permanent connection. Where a mains supply does exist, the same unit accepts 85–265 VAC. For sites with intermittent security concerns we also supply a lockable stainless enclosure with a tamper switch wired to the alarm relay.

Send us the channel width, maximum depth and expected flow range

We will recommend the structure type, confirm achievable accuracy and quote the complete open channel system with telemetry options.

Product Highlights

Ultrasonic open channel flowmeter for weir, flume and area-velocity discharge measurement in channels 0.3-10 m wide. Non-contact level sensing stays clear of silt and debris, with 1% of reading on structured channels, two years of interval logging and solar-compatible power for remote outfalls.

RELATED PRODUCTS
Quality Petroleum Radar Level Gauge 26GHz High Temperature Industrial factory

Petroleum Radar Level Gauge 26GHz High Temperature Industrial

Petroleum Radar Level Gauge brings 26GHz radar precision and high-temperature capability to oil storage tank measurement. Every millimeter of level is tracked accurately to prevent inventory loss and safety risk. Inquire now for specifications.

Quality Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor factory

Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor

Portable FMCW Radar Level Gauge brings laboratory-grade radar measurement to any tank in the plant or field. With IP67 protection and quick setup, it delivers accurate liquid level readings without permanent installation. Contact us for specifications.

Quality Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay factory

Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay

Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.

Quality Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement factory

Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement

Universal Gauge Pressure Transmitter measures pressure relative to the atmosphere for pump discharge, line pressure, tank head and filter differential applications. With 4-20mA output, it suits oil, water and gas measurement. Contact us for range options.

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.