Ultrasonic Open Channel Flowmeter QWUS-OC3000 Weir Flume Effluent Discharge Compliance Monitoring
Product Details
| Channel Width Range: | 0.3-10 M | Level Measurement: | Non-contact Ultrasonic, 0-3 M, 1 Mm Resolution |
|---|---|---|---|
| Velocity Measurement: | Doppler Sensor, 0.02-6 M/s Bidirectional | Accuracy: | +/-1% Of Reading With Weir Or Flume, 2-5% Area-velocity |
| Supported Structures: | V-notch And Rectangular Weirs, Parshall, Palmer-Bowlus, Cut-throat Flumes | Fluid Temperature: | 0-60 C |
| Enclosure Protection: | Sensor IP67, Converter IP65 | Data Logging: | Two Years At 15-minute Intervals, CSV Export |
| Outputs And Telemetry: | 4-20mA, Pulse, Relay, RS485 Modbus RTU, GPRS/NB-IoT Optional | Power Supply: | 85-265 VAC, 12 VDC Or Solar With Battery |
| Highlight |
Ultrasonic Open Channel Flowmeter,Weir Flume Discharge Measurement,Non-Contact Level and Velocity Sensing |
||
Product Description
Grab samples and staff gauge readings were adequate when the reporting cycle was annual. They are not adequate now. Regulators increasingly ask for daily or hourly discharge volume, and the same agencies compute load charges from those volumes. Meanwhile the practical problem at most sites is that an open channel has no pressure, no full pipe and no stable cross-section, so the instruments that work beautifully on a pressurised line — magnetic, turbine, positive displacement — have nothing to work with.
Four conditions define open channel duty, and all of them are common in plants that have already tried something else:
- The flow is not full. A pipe running at half depth cannot be metered by any full-bore device; the wetted area changes with level, so level itself has to be a measured variable.
- The instrument sits in a hostile place. Silt, rag, grit, algae and flood debris accumulate on anything submerged, and submersible sensors in raw sewage need cleaning on a schedule nobody has staff for.
- Reporting is auditable. Monthly totals must be reconstructable from stored records, with the structure dimensions and the equation used, not inferred from a single visit.
- Remote sites have no mains power. A headworks or a storm outfall often has to run on solar with telemetry, which rules out instruments that draw tens of watts continuously.
| Service condition | What the site normally sees | Commercial consequence | How the open channel meter responds |
|---|---|---|---|
| Structured channel V-notch weir or Parshall flume, steady dry-weather flow, silt depositing upstream |
Submerged level probes foul with silt and algae; floats jam; staff gauge readings are taken weekly and interpolated | Discharge totals are reconstructed from a handful of readings, so load charges and consent compliance cannot be defended during an inspection | Non-contact ultrasonic level referenced to the structure crest, logged every minute; silt below the beam has no effect on the reading |
| Unstructured channel Earthen or concrete ditch, variable backwater, storm surges, no weir present |
No hydraulic relationship exists, so a level-only device produces a number that is wrong at every depth above the calibration point | Irrigation allocation is applied as a pro-rata estimate; storm overflow volumes go unrecorded while the receiving water impact is still chargeable | Area-velocity mode measures depth and surface velocity together, computing discharge from the live cross-section instead of an assumed curve |
Discharge in an open channel is the product of wetted area and mean velocity, and neither term can be assumed when the channel is not full. The OC3000 solves the two halves of that equation in one instrument: an upward-looking ultrasonic transducer measures water level from the surface, and either a built-in hydraulic structure relationship or a Doppler velocity sensor supplies the second term.
- Structured channel route. Once the weir or flume geometry is entered — crest width, notch angle, throat width, approach width — the converter applies the standard head-discharge equation for that structure. Level accuracy then dominates the result, which is why a non-contact sensor with millimetre resolution is the right front end.
- Area-velocity route. Where no structure exists, a submerged or side-mounted Doppler sensor measures mean velocity near the bed, and the converter combines it with the wetted area computed from the measured level and the surveyed channel profile.
- Zero and datum stability. The reference datum is set at commissioning and stored, so a sensor that is re-aimed after maintenance returns to the same datum instead of silently shifting the whole discharge curve.
- Backwater and surcharge flags. If the level rises above the modular limit of the structure, submerged-flow correction is applied and the event is logged, so totals during a storm are marked rather than quietly wrong.
The accuracy statement follows from that logic. On a weir or flume in modular flow, ±1 % of reading is achievable because the hydraulic relationship is fixed and only the head has to be measured well. In area-velocity mode, expect ±2 % to ±5 % depending on how well the channel profile is surveyed and how uniform the velocity distribution is at the measuring section.
The single largest maintenance cost in open channel metering is not the instrument — it is the visits to clean it. A sensor that never enters the water removes that cost entirely, and it changes what the instrument can survive.
The structure decision usually comes before the instrument decision, and it should be driven by what the channel can physically accept. A V-notch weir gives the best low-flow resolution and is ideal for small effluent ditches, but it needs a stilling approach and it will be drowned by backwater. A Parshall or Palmer-Bowlus flume passes solids and tolerates a flatter gradient, at the cost of poor resolution at very low flow. Where the channel is earthen, irregular or already built with no head available, area-velocity sensing avoids civil work altogether. Measure the channel width, the maximum depth, the expected flow band and the available upstream straight length, and the correct answer usually becomes obvious.
| Industry | Municipal wastewater treatment |
| Site and region | Wastewater treatment plant, Lima, Peru |
| Application point | Final effluent channel downstream of chlorination, discharging to a coastal outfall |
| Fluid and temperature | Treated municipal effluent, 1–2 % residual solids, 18–26 °C |
| Channel and flow range | Concrete channel 1.2 m wide with existing Parshall flume, 180–2 400 m³/h |
| Measurement challenge | Submerged level probes had been cleaned weekly and still drifted; the consent required hourly discharge reporting that the plant could not produce |
| Configuration supplied | QWUS-OC3000 with non-contact level sensor, Parshall flume equation loaded, 4–20 mA to plant SCADA plus 15-minute internal logging |
| Accuracy achieved | ±1 % of reading in modular flow, verified against a portable reference during three flow conditions |
| Commissioning time | Three hours including datum setting and two-point verification; no channel modification |
| Verified result | Hourly discharge records accepted at the first regulatory audit; probe cleaning eliminated from the maintenance schedule |
| Industry | Agricultural irrigation and water distribution |
| Site and region | Irrigation district headworks, Nile Delta, Egypt |
| Application point | Secondary canal offtake supplying approximately 600 hectares of farmland |
| Fluid and temperature | Irrigation water with fine silt, 15–32 °C |
| Channel and flow range | Trapezoidal earthen channel, 2.6 m top width, depth 0.2–1.4 m, 0.15–3.4 m³/s |
| Measurement challenge | No weir or flume existed and no head was available to build one; no mains power at the offtake; allocation disputes with downstream users |
| Configuration supplied | QWUS-OC3000 area-velocity configuration, submerged Doppler velocity sensor, surveyed trapezoidal profile, solar panel with 12 V battery, GPRS telemetry |
| Accuracy achieved | ±3 % of reading after profile survey and current-meter cross-check at two depths |
| Commissioning time | One day including channel cross-section survey, sensor mounting and telemetry link test |
| Verified result | Daily allocation volumes published from telemetry; the seasonal dispute was resolved with a shared record both parties accepted |
| Channel width range | 0.3 – 10 m (wider channels quoted individually) |
| Level measurement | Non-contact ultrasonic, range 0 – 3 m, resolution 1 mm, beam angle 8° |
| Velocity measurement | Doppler sensor, 0.02 – 6 m/s bidirectional (area-velocity configuration) |
| Accuracy | ±1 % of reading with weir or flume in modular flow; ±2–5 % in area-velocity mode |
| Supported structures | V-notch and rectangular weirs; Parshall, Palmer-Bowlus and cut-throat flumes; custom head-discharge table import |
| Fluid temperature | 0 – 60 °C (sensor rated −20 – 70 °C ambient) |
| Enclosure protection | Sensor IP67; converter IP65 with lockable enclosure option for outdoor installation |
| Data logging | Internal memory for two years at 15-minute intervals, battery-backed, CSV export via USB |
| Outputs and telemetry | 4–20 mA, pulse, relay alarm, RS485 Modbus RTU; GPRS / NB-IoT module optional |
| Power supply | 85–265 VAC, 12 VDC or solar with battery; consumption below 0.5 W in logging mode |
Start from the civil constraint rather than from the instrument. If the channel is small, has reliable free fall and low flow must be resolved precisely, a V-notch weir is the strongest choice because head varies steeply with flow. If the water carries solids and the gradient is flat, a Parshall or Palmer-Bowlus flume passes debris and needs less head. If there is no structure, no available fall and no budget for civil work, area-velocity measurement avoids construction entirely and delivers ±2–5 % with a proper channel survey. Send channel width, maximum depth, expected flow band and a photograph of the site, and we will recommend one route and state the accuracy you can realistically expect from it.
Not in the way it affects submerged instruments. The level transducer looks down from above the water, so silt on the bed changes the channel invert but not the surface reading, and algae cannot grow on a dry sensor face. Debris passing underneath is only a problem if it is large enough to break the acoustic path for a sustained period, which is uncommon and self-clearing. The practical maintenance item is the sensor face itself: dust, cobwebs and bird droppings attenuate the beam, so a wipe during the annual inspection is usually enough. Diagnostics report echo strength continuously, so a degrading face shows up as a falling signal figure long before the flow record becomes unreliable.
That depends on traceability rather than on the sensor alone. Every OC3000 shipment includes a configuration record listing the structure type, crest or throat dimensions, the equation applied and the datum used, and the instrument logs interval data with timestamps and backwater flags. Together those give an auditor a reconstructable trail from raw level to reported volume, which is the question that is actually asked during an inspection. Where a consent specifies a particular standard method, tell us which one at the enquiry stage and we will confirm whether the structure equation is supported. Periodic verification against a portable reference is recommended annually and forms part of the evidence pack.
Yes. In low-power logging mode the instrument draws under 0.5 W, so a 20–40 W panel with a 12 V sealed battery carries a typical headworks or outfall through cloudy periods and keeps the logger running. The choice that affects battery life more than anything else is telemetry: continuous cellular links dominate consumption, so we normally configure scheduled uploads, for example every fifteen minutes with an event-triggered alert on level rise, instead of a permanent connection. Where a mains supply does exist, the same unit accepts 85–265 VAC. For sites with intermittent security concerns we also supply a lockable stainless enclosure with a tamper switch wired to the alarm relay.
Send us the channel width, maximum depth and expected flow range
We will recommend the structure type, confirm achievable accuracy and quote the complete open channel system with telemetry options.
An open channel is metered from above, because the wetted area changes with level and no full-bore device applies. Once the discharge leaves the channel and enters a pressurised pipe, the question changes: a transit-time spool piece ultrasonic flowmeter is the right instrument for clean closed loops at 0.5 % of reading, while a clamp-on Doppler ultrasonic flowmeter for slurry covers solids-laden lines that cannot be cut. Selecting the principle by channel or pipe condition, rather than by instrument family, is what keeps the reported volume defensible.
Related flow measurement options
Product Highlights
Ultrasonic open channel flowmeter for weir, flume and area-velocity discharge measurement in channels 0.3-10 m wide. Non-contact level sensing stays clear of silt and debris, with 1% of reading on structured channels, two years of interval logging and solar-compatible power for remote outfalls.
Petroleum Radar Level Gauge 26GHz High Temperature Industrial
Petroleum Radar Level Gauge brings 26GHz radar precision and high-temperature capability to oil storage tank measurement. Every millimeter of level is tracked accurately to prevent inventory loss and safety risk. Inquire now for specifications.
Portable FMCW Radar Level Gauge IP67 Liquid Measurement Sensor
Portable FMCW Radar Level Gauge brings laboratory-grade radar measurement to any tank in the plant or field. With IP67 protection and quick setup, it delivers accurate liquid level readings without permanent installation. Contact us for specifications.
Intelligent Digital Pressure Transmitter Multi-Unit LCD Alarm Relay
Digital pressure transmitter with integrated backlit LCD, local pushbutton configuration, and alarm relay output. Multi-unit display (MPa, kPa, bar, psi, kgf/cm²), IP67 protection, and HART 7 protocol for smart plant integration.
Universal Gauge Pressure Transmitter 4-20mA Oil Water Gas Measurement
Universal Gauge Pressure Transmitter measures pressure relative to the atmosphere for pump discharge, line pressure, tank head and filter differential applications. With 4-20mA output, it suits oil, water and gas measurement. Contact us for range options.
Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.